Emphysema quantification using low-dose computed tomography with deep learning-based kernel conversion comparison

被引:18
作者
Bak, So Hyeon [1 ]
Kim, Jong Hyo [2 ,3 ,4 ,5 ]
Jin, Hyeongmin [2 ,6 ]
Kwon, Sung Ok [7 ]
Kim, Bom [8 ]
Cha, Yoon Ki [9 ]
Kim, Woo Jin [10 ,11 ]
机构
[1] Kangwon Natl Univ, Kangwon Natl Univ Hosp, Dept Radiol, Sch Med, Chunchon, South Korea
[2] Grad Sch Convergence Sci & Technol, Program Biomed Radiat Sci, Dept Transdisciplinary Studies, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiol, Seoul, South Korea
[4] Adv Inst Convergence Technol, Ctr Med IT Convergence Technol Res, Suwon, South Korea
[5] Seoul Natl Univ, Dept Radiol, Coll Med, 103 Daehak Ro, Seoul 03080, South Korea
[6] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul, South Korea
[7] Kangwon Natl Univ Hosp, Biomed Res Inst, Chunchon, South Korea
[8] Kangwon Natl Univ Hosp, Environm Hlth Ctr, Chunchon, South Korea
[9] Dongguk Univ, Dept Radiol, Ilsan Hosp, Goyang, South Korea
[10] Kangwon Natl Univ, Sch Med, Dept Internal Med, 1 Kangwondaehak Gil, Chunchon 24341, Gangwon Do, South Korea
[11] Kangwon Natl Univ, Sch Med, Environm Hlth Ctr, 1 Kangwondaehak Gil, Chunchon 24341, Gangwon Do, South Korea
基金
新加坡国家研究基金会;
关键词
Emphysema; Deep learning; Densitometry; Tomography; PULMONARY-EMPHYSEMA; SMOKING-CESSATION; CT; DENSITY;
D O I
10.1007/s00330-020-07020-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective This study determined the effect of dose reduction and kernel selection on quantifying emphysema using low-dose computed tomography (LDCT) and evaluated the efficiency of a deep learning-based kernel conversion technique in normalizing kernels for emphysema quantification. Methods A sample of 131 participants underwent LDCT and standard-dose computed tomography (SDCT) at 1- to 2-year intervals. LDCT images were reconstructed with B31f and B50f kernels, and SDCT images were reconstructed with B30f kernels. A deep learning model was used to convert the LDCT image from a B50f kernel to a B31f kernel. Emphysema indices (EIs), lung attenuation at 15th percentile (perc15), and mean lung density (MLD) were calculated. Comparisons among the different kernel types for both LDCT and SDCT were performed using Friedman's test and Bland-Altman plots. Results All values of LDCT B50f were significantly different compared with the values of LDCT B31f and SDCT B30f (p < 0.05). Although there was a statistical difference, the variation of the values of LDCT B50f significantly decreased after kernel normalization. The 95% limits of agreement between the SDCT and LDCT kernels (B31f and converted B50f) ranged from - 2.9 to 4.3% and from - 3.2 to 4.4%, respectively. However, there were no significant differences in EIs and perc15 between SDCT and LDCT converted B50f in the non-chronic obstructive pulmonary disease (COPD) participants (p > 0.05). Conclusion The deep learning-based CT kernel conversion of sharp kernel in LDCT significantly reduced variation in emphysema quantification, and could be used for emphysema quantification.
引用
收藏
页码:6779 / 6787
页数:9
相关论文
共 29 条
  • [1] Short-term effect of changes in smoking behaviour on emphysema quantification by CT
    Ashraf, Haseem
    Lo, Pechin
    Shaker, Saher Burhan
    de Bruijne, Marleen
    Dirksen, Asger
    Tonnesen, Philip
    Dahlback, Magnus
    Pedersen, Jesper Holst
    [J]. THORAX, 2011, 66 (01) : 55 - 60
  • [2] Equating quantitative emphysema measurements on different CT image reconstructions
    Bartel, Seth T.
    Bierhals, Andrew J.
    Pilgram, Thomas K.
    Hong, Cheng
    Schechtman, Kenneth B.
    Conradi, Susan H.
    Gierada, David S.
    [J]. MEDICAL PHYSICS, 2011, 38 (08) : 4894 - 4902
  • [3] Imaging Advances in Chronic Obstructive Pulmonary Disease Insights from the Genetic Epidemiology of Chronic Obstructive Pulmonary Disease (COPDGene) Study
    Bhatt, Surya P.
    Washko, George R.
    Hoffman, Eric A.
    Newell, John D., Jr.
    Bodduluri, Sandeep
    Diaz, Alejandro A.
    Galban, Craig J.
    Silverman, Edwin K.
    Estepar, Raul San Jose
    Lynch, David A.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (03) : 286 - 301
  • [4] Emphysema: Effect of reconstruction algorithm on CT imaging measures
    Boedeker, KL
    McNitt-Gray, MF
    Rogers, SR
    Truong, DA
    Brown, MS
    Gjertson, DW
    Goldin, JG
    [J]. RADIOLOGY, 2004, 232 (01) : 295 - 301
  • [5] Robust, Standardized Quantification of Pulmonary Emphysema in Low Dose CT Exams
    Ceresa, Mario
    Bastarrika, Gorka
    de Torres, Juan P.
    Montuenga, Luis M.
    Zulueta, Javier J.
    Ortiz-de-Solorzano, Carlos
    Munoz-Barrutia, Arrate
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (11) : 1382 - 1390
  • [6] Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product
    Deak, Paul D.
    Smal, Yulia
    Kalender, Willi A.
    [J]. RADIOLOGY, 2010, 257 (01) : 158 - 166
  • [7] Normalized emphysema scores on low dose CT: Validation as an imaging biomarker for mortality
    Gallardo-Estrella, Leticia
    Pompe, Esther
    de Jong, Pim A.
    Jacobs, Colin
    van Rikxoort, Eva M.
    Prokop, Mathias
    Sanchez, Clara I.
    van Ginneken, Bram
    [J]. PLOS ONE, 2017, 12 (12):
  • [8] Normalizing computed tomography data reconstructed with different filter kernels: effect on emphysema quantification
    Gallardo-Estrella, Leticia
    Lynch, David A.
    Prokop, Mathias
    Stinson, Douglas
    Zach, Jordan
    Judy, Philip F.
    van Ginneken, Bram
    van Rikxoort, Eva M.
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (02) : 478 - 486
  • [9] COMPARISON OF COMPUTED DENSITY AND MACROSCOPIC MORPHOMETRY IN PULMONARY-EMPHYSEMA
    GEVENOIS, PA
    DEMAERTELAER, V
    DEVUYST, P
    ZANEN, J
    YERNAULT, JC
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (02) : 653 - 657
  • [10] Comparison of standard- and low-radiation-dose CT for quantification of emphysema
    Gierada, David S.
    Pilgram, Thomas K.
    Whiting, Bruce R.
    Hong, Cheng
    Bierhals, Andrew J.
    Kim, Jin Hwan
    Bae, Kyongtae T.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) : 42 - 47