CFD analysis of temperature imbalance in superheater/reheater region of tangentially coal-fired boiler

被引:1
|
作者
Zainudin, A. F. [1 ]
Hasini, H. [1 ]
Fadhil, S. S. A. [1 ]
机构
[1] Univ Tenaga Nas, Fluid Dynam & Risk Reduct Res Grp, Inst Sustainable Engn, Jalan IKRAM UNITEN, Kajang 43000, Selangor, Malaysia
来源
4TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING RESEARCH (ICMER2017) | 2017年 / 257卷
关键词
LARGE-SCALE; DEVIATION; COMBUSTION; EMISSIONS; FLOW;
D O I
10.1088/1757-899X/257/1/012062
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a CFD analysis of the flow, velocity and temperature distribution in a 700 MW tangentially coal-fired boiler operating in Malaysia. The main objective of the analysis is to gain insights on the occurrences in the boiler so as to understand the inherent steam temperature imbalance problem. The results show that the root cause of the problem comes from the residual swirl in the horizontal pass. The deflection of the residual swirl due to the sudden reduction and expansion of the flow cross-sectional area causes velocity deviation between the left and right side of the boiler. This consequently results in flue gas temperature imbalance which has often caused tube leaks in the superheater/reheater region. Therefore, eliminating the residual swirl or restraining it from being diverted might help to alleviate the problem.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Combustion process simulation of a tangentially coal blend fired boiler
    Fang, Qingyan
    Zhou, Huaichun
    Huang, Lai
    Yao, Bin
    Wang, Huajian
    PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON COAL COMBUSTION, 2007, : 280 - 287
  • [32] Analysis of carbon loss from a pulverized coal-fired boiler
    Walsh, PM
    ENERGY & FUELS, 1997, 11 (05) : 965 - 971
  • [33] Data Mining In Conditions Analysis At A Coal-Fired Utility Boiler
    Liu BaoLing
    MEMS, NANO AND SMART SYSTEMS, PTS 1-6, 2012, 403-408 : 223 - 227
  • [34] CFD study of pulverized coal-fired boiler evaporator and radiant superheaters at varying loads
    Laubscher, Ryno
    Rousseau, Pieter
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [35] FIRESIDE CORROSION OF REHEATER TUBES - 500 MW COAL FIRED BOILER
    WRIGHT, D
    MITCHELL, PJ
    ASTON, J
    ERDOL & KOHLE ERDGAS PETROCHEMIE, 1981, 34 (04): : 174 - 174
  • [36] Analysis of a Failed Primary Superheater Tube and Life Assessment in a Coal-Fired Powerplant
    Ilman M.N.
    Prihajatno M.
    Kusmono
    Journal of Failure Analysis and Prevention, 2015, 15 (02) : 200 - 204
  • [37] CURRENT COAL-FIRED BOILER TECHNOLOGY IN CHINA
    LEE, GK
    LAU, IT
    JOURNAL OF THE INSTITUTE OF ENERGY, 1985, 58 (437): : 197 - 209
  • [38] Modeling of a coal-fired natural circulation boiler
    Bhambare, K. S.
    Mitra, Sushanta K.
    Gaitonde, U. N.
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2007, 129 (02): : 159 - 167
  • [39] Study of dewpoint corrosion of coal-fired boiler
    Zhang, Z.-X. (zhangzhixiang274@163.com), 2012, Beijing Institute of Aeronautical Materials (BIAM)
  • [40] SUPERHEATER FOULING DUE TO LIMESTONE INJECTION IN COAL-FIRED BOILERS
    SKRIFVARS, BJ
    HUPA, M
    HYOTY, P
    JOURNAL OF THE INSTITUTE OF ENERGY, 1991, 64 (461): : 196 - 201