Limitations of Incident Power Density as a Proxy for Induced Electromagnetic Fields

被引:17
作者
Christ, Andreas [1 ]
Samaras, Theodoros [2 ]
Neufeld, Esra [1 ]
Kuster, Niels [1 ,3 ]
机构
[1] ITIS Fdn, Zeughausstr 43, CH-8004 Zurich, Switzerland
[2] Aristotle Univ Thessaloniki, Dept Phys, Thessaloniki, Greece
[3] Swiss Fed Inst Technol, Zurich, Switzerland
关键词
millimeter wave exposure; incident power density; basic restrictions and reference levels; near-field coupling; compliance with exposure limits; ENERGY-ABSORPTION; FREQUENCY-RANGE; TISSUE COMPOSITION; HUMAN EXPOSURE; DEPENDENCE;
D O I
10.1002/bem.22268
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The most recent safety guidelines define basic restrictions for electromagnetic field exposure at frequencies more than 6 GHz in terms of spatial- and time-averaged transmitted power density inside the body. To enable easy-to-perform evaluations in situ, the reference levels for the incident power density were derived. In this study, we examined whether compliance with the reference levels always ensures compliance with basic restrictions. This was evaluated at several distances from different antennas (dipole, loop, slot, patch, and helix). Three power density definitions based on integration of the perpendicular real part of the Poynting vector, the real part of its three vector components, and its modulus were compared for averaging areas of lambda(2)/16, 4 cm(2) (below 30 GHz) and 1 cm(2) (30 GHz). In the reactive near-field (d < lambda/(2 pi)), the transmitted power density can be underestimated if an antenna operates at the free space exposure limit. This underestimation may exceed 6 dB (4.0 times) and depends on the field source due to different coupling mechanisms. It is frequency-dependent for fixed-size averaging areas (4 and 1 cm(2)). At larger distances, transmission can be larger than the theoretical plane-wave transmission coefficient due to backscattering between the body and field source. Using the modulus of the incident Poynting vector yields the smallest underestimation. (c) 2020 Bioelectromagnetics Society.
引用
收藏
页码:348 / 359
页数:12
相关论文
共 33 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
[Anonymous], 2019, press release
[3]  
[Anonymous], 2016, 622092 IEC
[4]  
[Anonymous], 2005, C951 IEEE
[5]  
[Anonymous], 2016, 622091 IEC
[6]  
[Anonymous], 2019, Discussion with Muslim Brotherhood intellectual with close ties to the movement, European capital
[7]  
Carrasco E, 2018, RAD PROT DOSIM, V183, P488
[8]   A numerical and experimental comparison of human head phantoms for compliance testing of mobile telephone equipment [J].
Christ, A ;
Chavannes, N ;
Nikoloski, N ;
Gerber, HU ;
Pokovic, K ;
Kuster, N .
BIOELECTROMAGNETICS, 2005, 26 (02) :125-137
[9]   The dependence of electromagnetic far-field absorption on body tissue composition in the frequency range from 300 MHz to 6 GHz [J].
Christ, Andreas ;
Klingenboeck, Anja ;
Samaras, Theddoros ;
Goiceanu, Cristian ;
Kuster, Niels .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (05) :2188-2195
[10]   RF-INDUCED TEMPERATURE INCREASE IN A STRATIFIED MODEL OF THE SKIN FOR PLANE-WAVE EXPOSURE AT 6-100 GHZ [J].
Christ, Andreas ;
Samaras, Theodoros ;
Neufeld, Esra ;
Kuster, Niels .
RADIATION PROTECTION DOSIMETRY, 2020, 188 (03) :350-360