Comparison between regional micropush-out and microtensile bond strength of resin composite to dentin

被引:21
作者
Cekic-Nagas, Isil [1 ]
Ergun, Gulfem [1 ]
Nagas, Emre [2 ]
Tezvergil, Arzu [3 ]
Vallittu, Pekka K. [3 ]
Lassila, Lippo V. J. [3 ]
机构
[1] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Endodont, Ankara, Turkey
[3] Univ Turku, Inst Dent, Dept Prosthet Dent & Biomat Sci, Turku, Finland
基金
芬兰科学院;
关键词
dentin depth; micropush-out; microtensile; resin composite; surface;
D O I
10.1080/00016350801958266
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In this study we compared the micropush-out (mu-PO) and microtensile (mu-TBS) test methods for resin composites on different levels and surfaces of dentin. Material and Methods. Thirty-four sound human molars were divided into two groups in accordance with the dentin surface used (occlusal (O) or mesio-distal (M)), then subdivided into a further two groups in accordance with the test method (mu-PO (P) or mu-TBS (T)). In groups OP and OT, teeth were ground occlusally perpendicular to their axis, and in groups MP and MT, mesio-distally parallel to their axis to expose dentin. Dentin disks were prepared from different regions of the teeth either in an occluso-cervical (group OP) (n = 5) or mesiodistal direction (group MP) (n = 5) (S, superficial; M, middle; D, deep). One-hundred-and-twenty standardized occlusal cavities were prepared in these dentin disks using a conical-shaped diamond rotary cutting instrument. The adhesive (Adper Scotchbond Multi-Purpose Dental Adhesive) and a composite material (Filtek Z250 Universal Restorative) were applied and polymerized with a LED light curing unit (Elipar FreeLight 2). The disks (n = 20/per group) were tested in a universal testing machine and pushed out with a cross-head speed of 1.0 mm/min. In groups OT (n = 12) and MT (n = 12), the teeth were ground to expose superficial, middle, and deep dentin. Build-ups of resin composite were constructed with the same materials. The specimens were serially sectioned and trimmed to hour-glass shapes, then tested with the mu-TBS tester at a rate of 1 mm/min. Failure modes were examined using a stereomicroscope and scanning electron microscope. Results. ANOVA revealed significant differences among the groups (p < 0.001). With the push-out test, no premature failure occurred, the variability of the data distribution was acceptable, and regional differences in bond strength among dentin levels could be assessed. Conclusions. The mu-PO test method could be an alternative to the mu-TBS technique.
引用
收藏
页码:73 / 81
页数:9
相关论文
共 34 条
[31]   Increases in dentin-bond strength if doubling application time of an acetone-containing one-step adhesive [J].
Toledano, M. ;
Proenca, J. P. ;
Erhardt, M. C. G. ;
Osorio, E. ;
Aguilera, F. S. ;
Osorio, R. ;
Tay, F. R. .
OPERATIVE DENTISTRY, 2007, 32 (02) :133-137
[32]   Microhardness of acid-treated and resin infiltrated human dentine [J].
Toledano, M ;
Osorio, R ;
Osorio, E ;
Prati, C ;
Carvalho, RM .
JOURNAL OF DENTISTRY, 2005, 33 (04) :349-354
[33]   Comparison of interfacial characteristics of adhesive bonding to superficial versus deep dentine using SEM and straining techniques [J].
Wang, Y ;
Spencer, P ;
Hager, C ;
Bohaty, B .
JOURNAL OF DENTISTRY, 2006, 34 (01) :26-34
[34]   Micro-tensile bond strength of three luting resins to human regional dentin [J].
Yang, B ;
Ludwig, K ;
Adelung, R ;
Kern, M .
DENTAL MATERIALS, 2006, 22 (01) :45-56