A simple and sensitive LC-MS/MS method for the determination of sotalol in rat plasma

被引:9
作者
Feng, Zhiping [1 ,2 ]
Yu, Siyuan [1 ,2 ]
Liu, Wei [1 ]
Yang, Li [1 ]
Liu, Yang [1 ]
Zhai, Suodi [1 ]
Wang, Fang [2 ]
Zhang, Xianhua [1 ]
机构
[1] Peking Univ, Dept Pharm, Hosp 3, Beijing 100191, Peoples R China
[2] Affiliated Jiangmen Hosp Sun Yat Sen, Jiangmen Cent Hosp, Dept Pharm, Jiangmen City 529000, Guangdong, Peoples R China
关键词
sotalol; LC-MS; MS; rat plasma; validation; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; BETA-BLOCKERS; CLASSIFICATION;
D O I
10.1002/bmc.3403
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, rapid and robust HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the quantification of sotalol in rat plasma. Plasma samples were precipitated with acetonitrile before analysis. The chromatographic separation was performed on an Atlantis hydrophilic interaction liquid chromatography Silica column (50x2.1mm, 3 mu m) with a gradient mobile phase of 10mm NH4COOH (containing 0.2% of formic acid) as buffer A and acetonitrile as mobile phase B. Sotalol (m/z 273.2255.1) and atenolol (the internal standard, IS, m/z 267.2190.1) were monitored under positive ionization mode with 5500 QTRAP. Retention time of sotalol and the IS were 2.69 and 3.43min, respectively. The linear range was 5-500nm based on the analysis of 0.1mL of plasma. The intrabatch precision ranged from 1.2 to 6.1%, and the inter-batch precision was from 3.3 to 6.5%. The coefficient of variation of IS-normalized matrix factor was 7.6%. Experiments for stability were performed and the analyte was sufficiently stable. A run time of 6min for each injection made it possible to analyze a high throughput of plasma samples. The assay was successfully applied to the determination of sotalol in rat plasma after a micro-dose oral administration. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:1167 / 1172
页数:6
相关论文
共 22 条
  • [1] A THEORETICAL BASIS FOR A BIOPHARMACEUTIC DRUG CLASSIFICATION - THE CORRELATION OF IN-VITRO DRUG PRODUCT DISSOLUTION AND IN-VIVO BIOAVAILABILITY
    AMIDON, GL
    LENNERNAS, H
    SHAH, VP
    CRISON, JR
    [J]. PHARMACEUTICAL RESEARCH, 1995, 12 (03) : 413 - 420
  • [2] Antonaccio MJ, 1993, AM J CARDIOL, V4, p27A
  • [3] Enantioselective liquid chromatographic-electrospray mass spectrometric assay of β-adrenergic blockers:: application to a pharmacokinetic study of sotalol in human plasma
    Badaloni, E
    D'Acquarica, I
    Gasparrini, F
    Lalli, S
    Misiti, D
    Pazzucconi, F
    Sirtori, CR
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (01): : 45 - 54
  • [4] Bertrix L, 1986, CARDIOVASC RES, V5, P358
  • [5] Development and validation of an automated method for the liquid chromatographic determination of sotalol in plasma using dialysis and trace enrichment on a cation-exchange pre-column as on-line sample preparation
    Chiap, P
    Ceccato, A
    Buraglia, BM
    Boulanger, B
    Hubert, P
    Crommen, J
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) : 801 - 814
  • [6] dasCunha LC, 2001, B CHIM FARM, V6, P448
  • [7] Simultaneous determination of thirteen β-blockers and one metabolite by gradient high-performance liquid chromatography with photodiode-array UV detection
    Delamoye, M
    Duverneuil, C
    Paraire, F
    de Mazancourt, P
    Alvarez, JC
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2004, 141 (01) : 23 - 31
  • [8] Development of a multi-residue analytical methodology based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for screening and trace level determination of pharmaceuticals in surface and wastewaters
    Gros, Meritxell
    Petrovic, Mira
    Barcelo, Damia
    [J]. TALANTA, 2006, 70 (04) : 678 - 690
  • [9] Cassette analysis of eight beta-blockers in bovine eye sclera, choroid-RPE, retina, and vitreous by liquid chromatography-tandem mass spectrometry
    Kadam, Rajendra S.
    Kompella, Uday B.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 253 - 260
  • [10] Small blood volumes from children for quantitative sotalol determination using high-performance liquid chromatography
    Läer, S
    Wauer, I
    Scholz, H
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02): : 421 - 425