The impact of combined-cycle gas turbine short-term dynamics on frequency control

被引:67
作者
Lalor, G [1 ]
Ritchie, J
Flynn, D
O'Malley, MJ
机构
[1] Univ Coll Dublin, Elect Res Ctr, Dept Elect & Elect Engn, Dublin 4, Ireland
[2] Queens Univ Belfast, Sch Elect & Elect Engn, Belfast BT9 5AH, Antrim, North Ireland
关键词
combined-cycle gas turbine (CCGT); frequency control; power generation control; power system security;
D O I
10.1109/TPWRS.2005.852058
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A model suitable for studying the short-term dynamic response of a combined-cycle gas turbine (CCGT) to a system frequency deviation is developed. The model is used in conjunction with a larger system model to study the impact of increasing levels of CCGT generation on frequency control of a small island system. The study considers single contingencies and does not consider severe cascading-type events. A consequence of the results is that as the number and proportion of base-loaded CCGTs increases, frequency control may become more challenging. The results indicate that with additional CCGTs on the system large frequency excursions will be more likely, and the transmission system operators on the island of Ireland should review their frequency control strategies in the future to avoid the shedding of customers.
引用
收藏
页码:1456 / 1464
页数:9
相关论文
共 25 条
[1]  
[Anonymous], P IEEE POW C BOL IT
[2]   Management and dynamic performances of combined cycle power plants during parallel and islanding operation [J].
Bagnasco, A ;
Delfino, B ;
Denegri, GB ;
Massucco, S .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1998, 13 (02) :194-201
[3]  
*CAN POW SYST OUT, 2003, INT REP CAUS AUG 14
[4]  
*CER, LIST LIC
[5]  
*CIGRE TASKF, 2003, MOD GAS TURB STEAM T
[6]  
DEMELLO FP, 1994, IEEE T POWER SYST, V9, P1698
[7]  
*DETINI, 2003, REP NIE RESP LOSS 2
[8]  
*ESB NAT GRID, GRID COD
[9]  
*ESB NAT GRID, SYST OP ANC SERV
[10]  
*ESB NAT GRID, 20042010 GEN AD REP