Dose optimization of contrast-enhanced carotid MR angiography

被引:13
作者
Unterweger, M [1 ]
Froehlich, JM [1 ]
Kubik-Huch, RA [1 ]
Seifert, B [1 ]
Birrer, M [1 ]
Huber, T [1 ]
Otto, R [1 ]
机构
[1] Cantonal Hosp Baden, Inst Radiol, CH-5404 Baden, Switzerland
关键词
carotid arteries; magnetic resonance angiography; contrast media; contrast dose; gadolinium;
D O I
10.1007/s00330-005-2756-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to compare the diagnostic performance of a single-contrast or a double-contrast dose of carotid contrast-enhanced MR angiography (MRA). One-hundred nineteen patients ( mean age 65 +/- 14.4 years) underwent carotid contrast-enhanced MRA with a standardized protocol ( repetition time/echo 3.73 ms/1.38 ms, flip-angle 25 degrees, acquisition-time 19 s, voxel size 1.2 x 1.2 x 0.9 mm(3)) on a 1.5-T scanner ( Sonata, Siemens-Medical-Systems) using a neck phased-array coil. Contrast agent was administered intravenously at a rate of 3.0 ml/s, either as a single dose (n = 57; 0.1 mmol/kg body weight) or as a double dose (n = 62; 0.2 mmol/kg body weight) of meglumine gadoterate (0.5 M/l), followed by 30 ml saline. Qualitative image analysis was performed on maximum intensity projections using a five-point scale. Signal intensities were measured at three different vascular levels on both sides to assess the contrast-to-noise ratios (CNRs). Image quality was rated as good or excellent in all cases. A double dose did not influence the efficacy of carotid enhancement (CNR single dose 69.12 +/- 19.8; CNR double dose 70.01 +/- 20.7; p = 0.81) compared with a single dose. In both dose groups the mean CNRs were inversely related to bodyweight, despite adjusted contrast volumes (p = 0.0005). Double-dose contrast-enhanced carotid MRA is not superior to single-dose MRA, as overall diagnostic performance and quantitative contrast enhancement are equal. Being more cost-efficient, a single-dose administration of contrast agent is recommended for MRA of the carotid arteries.
引用
收藏
页码:1797 / 1805
页数:9
相关论文
共 30 条
[1]   Carotid MR angiography: Phase II study of safety and efficacy for MS-325 [J].
Bluemke, DA ;
Stillman, AE ;
Bis, KG ;
Grist, TM ;
Baum, RA ;
D'Agostino, R ;
Malden, ES ;
Pierro, JA ;
Yucel, EK .
RADIOLOGY, 2001, 219 (01) :114-122
[2]   Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes [J].
Boos, M ;
Scheffler, K ;
Haselhorst, R ;
Reese, E ;
Fröhlich, J ;
Bongartz, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :568-576
[3]   Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography [J].
Carroll, TJ ;
Korosec, FR ;
Petermann, GM ;
Grist, TM ;
Turski, PA .
RADIOLOGY, 2001, 220 (02) :525-532
[4]   Contrast-enhanced three-dimensional MR angiography of neck vessels: does dephasing effect alter diagnostic accuracy? [J].
Cosottini, M ;
Calabrese, R ;
Puglioli, M ;
Zampa, V ;
Michelassi, MC ;
Ortori, S ;
Murri, L ;
Bartolozzi, C .
EUROPEAN RADIOLOGY, 2003, 13 (03) :571-581
[5]   Atherosclerotic disease distribution in carotid and Vertebrobasilar arteries: Clinical experience in 100 patients undergoing fluoro-triggered 3D Gd-MRA [J].
Ersoy, H ;
Watts, R ;
Sanelli, P ;
Zimmerman, RD ;
Kent, KC ;
Bush, HL ;
Prince, MR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) :545-558
[6]   Time-resolved contrast-enhanced three-dimensional pulmonary MR-angiography:: 1.0 M gadobutrol vs. 0.5 M gadopentetate dimeglumine [J].
Fink, C ;
Bock, M ;
Kiessling, F ;
Lichy, MP ;
Krissak, R ;
Zuna, I ;
Schmähl, A ;
Delorme, S ;
Kauczor, HU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) :202-208
[7]   Using a 1 M Gd-chelate (gadobutrol) for total-body three-dimensional MR angiography:: preliminary experience [J].
Goyen, M ;
Herborn, CU ;
Vogt, FM ;
Kröger, K ;
Verhagen, R ;
Yang, F ;
Bosk, S ;
Debatin, JF ;
Ruehm, SG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) :565-571
[8]   Optimization of contrast dosage for gadolinium-enhanced 3D MRA of the pulmonary and renal arteries [J].
Hany, TF ;
Schmidt, M ;
Hilfiker, PR ;
Steiner, P ;
Bachmann, U ;
Debatin, JF .
MAGNETIC RESONANCE IMAGING, 1998, 16 (08) :901-906
[9]   BASIC PHYSICS OF MR CONTRAST AGENTS AND MAXIMIZATION OF IMAGE-CONTRAST [J].
HENDRICK, RE ;
HAACKE, EM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :137-148
[10]   Contrast-enhanced magnetic resonance angiography of the carotid arteries:: Influence of injection rates and volumes on arterial-venous transit time [J].
Herold, T ;
Paetzel, C ;
Völk, M ;
Bachthaler, M ;
Zorger, N ;
Feuerbach, S ;
Strotzer, M ;
Lenhart, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (02) :65-72