Comparison of Accuracy of Pedicle Screw Insertion Among 4 Guided Technologies in Spine Surgery

被引:63
作者
Fan, Yong [1 ]
Du, Jinpeng [1 ,2 ]
Zhang, Jianan [1 ]
Liu, Shichang [1 ]
Xue, Xukai [1 ]
Huang, Yunfei [1 ]
Zhang, Jing [1 ]
Hao, Dingjun [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Honghui Hosp, Dept Spine Surg, Xian, Shaanxi, Peoples R China
[2] Yanan Univ, Med Coll, Yanan, Shanxi, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2017年 / 23卷
关键词
Bone Screws; Fluoroscopy; Robotics; Surgery; Computer-Assisted; Templates; Genetic; PLACEMENT ACCURACY; LUMBAR SPINE; GUIDANCE;
D O I
10.12659/MSM.905713
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: As an available new tool for spinal surgery, robotic technology holds great potential and has been demonstrated to have better clinical outcomes compared with traditional techniques. However, it has not been compared with other assisted tools for the treatment of lumbar degenerative disease. This article focused on studying such variances. Material/Methods: A total of 176 pedicle screws were inserted in 39 patients using a spine robot (group 1), 134 screws were implanted in 28 patients using navigational template (group 2), 234 screws were implanted in 51 patients by O-arm-based navigation (group 3), and 346 screws were implanted in 72 patients by fluoroscopy-guided assistance (group 4). The screw position was evaluated using postoperative scans according to Rampersaud A to D classification, and other secondary data were also collected. Results: "Perfect" pedicle screw insertion (Grade A) was 90.34%, 91.79%, 84.19%, and 65.03% of groups 1-4, respectively. "Clinically acceptable" screw implantation (Grade A+B) was 94.32%, 95.52, 90.60%, and 78.03% in groups 1-4, respectively. Deviation sagittal (degrees) respectively was 3 +/- 9, 2 +/- 10, 4 +/- 7, and 10 +/- 8 degrees in groups 1-4, respectively. Deviation transversal (degrees) screw insertion was 3 +/- 8, 3 +/- 7, 4 +/- 9, and 8 +/- 13 degrees in groups 1-4, respectively. Statistical analysis showed group 1 had no significant difference in the accuracy of "Perfect and Clinical acceptable" as well as deviation sagittal or transversal, respectively, compared with groups 2 and 3 but not group 4. Conclusions: Robotic-assistance technology no clear advantage in terms of accuracy compared to the navigation template or O-arm systems for screw implantation, but it significantly reduced adverse events, fluoroscopy time per screw, postoperative stay, and blood loss.
引用
收藏
页码:5960 / 5968
页数:9
相关论文
共 19 条
  • [1] Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review
    Aoude, Ahmed A.
    Fortin, Maryse
    Figueiredo, Rainer
    Jarzem, Peter
    Ouellet, Jean
    Weber, Michael H.
    [J]. EUROPEAN SPINE JOURNAL, 2015, 24 (05) : 990 - 1004
  • [2] Robotic assisted spine surgery - a breakthrough or a surgical toy?
    Barzilay, Y.
    Kaplan, L.
    Libergall, M.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (03) : 195 - 196
  • [3] Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot Retrospective Study
    Devito, Dennis P.
    Kaplan, Leon
    Dietl, Rupert
    Pfeiffer, Michael
    Horne, Dale
    Silberstein, Boris
    Hardenbrook, Mitchell
    Kiriyanthan, George
    Barzilay, Yair
    Bruskin, Alexander
    Sackerer, Dieter
    Alexandrovsky, Vitali
    Stueer, Carsten
    Burger, Ralf
    Maeurer, Johannes
    Gordon, Donald G.
    Schoenmayr, Robert
    Friedlander, Alon
    Knoller, Nachshon
    Schmieder, Kirsten
    Pechlivanis, Ioannis
    Kim, In-Se
    Meyer, Bernhard
    Shoham, Moshe
    [J]. SPINE, 2010, 35 (24) : 2109 - 2115
  • [4] Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study
    Farshad, Mazda
    Betz, Michael
    Farshad-Amacker, Nadja A.
    Moser, Manuel
    [J]. EUROPEAN SPINE JOURNAL, 2017, 26 (03) : 738 - 749
  • [5] Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
    Guo, Fei
    Dai, Jianhao
    Zhang, Junxiang
    Ma, Yichuan
    Zhu, Guanghui
    Shen, Junjie
    Niu, Guoqi
    [J]. PLOS ONE, 2017, 12 (02):
  • [6] Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions A Randomized Controlled Trial
    Hyun, Seung-Jae
    Kim, Ki-Jeong
    Jahng, Tae-Ahn
    Kim, Hyun-Jib
    [J]. SPINE, 2017, 42 (06) : 353 - 358
  • [7] Evaluation of surgical strategy of conventional vs. percutaneous robot-assisted spinal trans-pedicular instrumentation in spondylodiscitis
    Keric N.
    Eum D.J.
    Afghanyar F.
    Rachwal-Czyzewicz I.
    Renovanz M.
    Conrad J.
    Wesp D.M.A.
    Kantelhardt S.R.
    Giese A.
    [J]. Journal of Robotic Surgery, 2017, 11 (1) : 17 - 25
  • [8] Kim HJ, 2016, INT J MED ROBOT
  • [9] Assessment of Pedicle Screw Placement Accuracy, Procedure Time, and Radiation Exposure Using a Miniature Robotic Guidance System
    Lieberman, Isador H.
    Hardenbrook, Mitchell A.
    Wang, Jeffrey C.
    Guyer, Richard D.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (05): : 241 - 248
  • [10] Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review
    Marcus, Hani J.
    Cundy, Thomas P.
    Nandi, Dipankar
    Yang, Guang-Zhong
    Darzi, Ara
    [J]. EUROPEAN SPINE JOURNAL, 2014, 23 (02) : 291 - 297