Recent highlights in graphite furnace atomic absorption spectrometry

被引:36
作者
Butcher, David J. [1 ]
机构
[1] Western Carolina Univ, Dept Chem & Phys, 111 Mem Dr, Cullowhee, NC 28723 USA
关键词
High resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS); hollow cathode lamp (HCL); solid-phase extraction (SPE); solid sampling; speciation; LIQUID-LIQUID MICROEXTRACTION; SOLID-PHASE EXTRACTION; FLOATING ORGANIC DROP; FAST ALKALINE SOLUBILIZATION; SAMPLE PREPARATION METHODS; ULTRA-TRACE DETERMINATION; CLOUD-POINT EXTRACTION; CS GF AAS; WATER SAMPLES; SEQUENTIAL DETERMINATION;
D O I
10.1080/05704928.2017.1303504
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Graphite furnace atomic absorption spectrometry (GFAAS) is an elemental analysis technique that has been employed for virtually all types of samples. Traditionally, hollow cathode lamps, line excitation sources, have been employed for excitation. However, in the past two decades, high resolution continuum source (HR CS) GFAAS has been shown to offer greater potential for multielemental analysis, greater flexibility in wavelength selection, the ability to determine molecules, and better characterization and correction for spectral backgrounds. The recent analytical literature is critically reviewed, including solubilization and preconcentration procedures. Solid and slurry sampling have been the focus of recent work; in particular, the enhanced capabilities of HR CS GFAAS provide green methodology with suitable sensitivity, precision, and accuracy. GFAAS has also been employed for elemental speciation, including characterization of forms using the atomization profiles.
引用
收藏
页码:755 / 773
页数:19
相关论文
共 112 条
[1]   Sequential determination of cadmium and lead in organic pharmaceutical formulations using high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Aleluia, Augusto C. M. ;
de Santana, Fernanda A. ;
Brandao, Geovani C. ;
Ferreira, Sergio L. C. .
MICROCHEMICAL JOURNAL, 2017, 130 :157-161
[2]  
Almeida JS, 2016, ANAL METHODS-UK, V8, P3249, DOI [10.1039/C6AY00165C, 10.1039/c6ay00165c]
[3]   Application of microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry for ultra-trace determination of lead and cadmium in cereals and agricultural products [J].
Ataee, Mari ;
Ahmadi-Jouibari, Toraj ;
Fattahi, Nazir .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (03) :271-283
[4]   Determination of Antimony from Polyethylene Terephthalate in Drinking Water by Solid Floating Organic Drop Microextraction and Electrothermal Atomization Atomic Absorption Spectrometry [J].
Atakan, Deniz ;
Durukan, Ilknur ;
Bektas, Sema .
ANALYTICAL LETTERS, 2016, 49 (07) :1066-1078
[5]   Determination of Lead in Iron Supplements by Electrothermal Atomization Atomic Absorption Spectrometry [J].
Barbosa, Uenderson A. ;
dos Santos, Ivanice F. ;
dos Santos, Ana M. P. ;
Ferreira, Sergio L. C. .
ANALYTICAL LETTERS, 2016, 49 (06) :799-807
[6]   Effect of different precursors on generation of reference spectra for structural molecular background correction by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry: Determination of antimony in cosmetics [J].
Barros, Ariane Isis ;
de Babos, Diego Victor ;
Ferreira, Edilene Cristina ;
Gomes Neto, Jose Anchieta .
TALANTA, 2016, 161 :547-553
[7]   Chemometric evaluation of Cd, Co, Cr, Cu, Ni (inductively coupled plasma optical emission spectrometry) and Pb (graphite furnace atomic absorption spectrometry) concentrations in lipstick samples intended to be used by adults and children [J].
Batista, Erica Ferreira ;
Augusto, Amanda dos Santos ;
Pereira-Filho, Edenir Rodrigues .
TALANTA, 2016, 150 :206-212
[8]   Determination of Cd, Co, Cr, Cu, Ni and Pb in cosmetic samples using a simple method for sample preparation [J].
Batista, Erica Ferreira ;
Augusto, Amanda dos Santos ;
Pereira-Filho, Edenir Rodrigues .
ANALYTICAL METHODS, 2015, 7 (01) :329-335
[9]   Determination of Mercury in Istanbul Airborne Particles Using Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry [J].
Baysal, Asli ;
Akman, Suleyman .
ANALYTICAL LETTERS, 2016, 49 (12) :1896-1902
[10]   Model calculation of the characteristic mass for convective and diffusive vapor transport in graphite furnace atomic absorption spectrometry [J].
Bencs, Laszlo ;
Laczai, Nikoletta ;
Ajtony, Zsolt .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 109 :52-59