Inter-observer reliability for amplitude-integrated EEG in the newborn with perinatal asphyxia

被引:3
作者
Bustamante-Hervas, Carmen [1 ]
Valverde, Eva [2 ,3 ]
Vega-Del-Val, Cristina [1 ]
Schuffelmann, Susana [1 ]
Arnaez, Juan [1 ,3 ]
机构
[1] Complejo Asistencial Univ Burgos, Unidad Neonatol, Burgos, Spain
[2] Hosp Univ Infantil La Paz, Serv Neonatol, Madrid, Spain
[3] Fdn NeNe, Madrid, Spain
来源
ANALES DE PEDIATRIA | 2022年 / 96卷 / 05期
关键词
aEEG; Amplitude integrated electroencephalography; Perinatal asphyxia; Hypoxic-ischemic encephalopathy; Neonate; Concordance; ELECTROENCEPHALOGRAPHY;
D O I
10.1016/j.anpedi.2021.01.014
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Introduction: Amplitude integrated electroencephalography (aEEG) is a widely tool used for neuromonitoring in the critical neonate. In the patient with perinatal asphyxia, its interpretation is key to identifying candidates for therapeutic hypothermia, detecting subclinical seizures and providing pronostic information. Our aim was to analyze the concordance in the interpretation of aEEG among neonatologists with different level of experience. Material and methods: Unicenter retrospective study of newborns >= 35 weeks with perinatal asphyxia included consecutively over a two-year period and monitored with aEEG for at least 6 h. The bedside neonatologist interpreted aEEG regarding background pattern, sleep-wake cycling, and seizures. The aEEG tracings were blindly reviewed by two neonatologists with different experience. The aEEG tracings were divided into periods of 0-3 h and 3-6 h of life, and the concordance (Cohen Kappa coefficient, k), between the two examiners and that of their consensus with the bedside neonatologist, was analyzed. Results: Seventy-five newborns were included, 5 of them were not aEEG-monitored. 132 tracings were analyzed with a very good concordance between the two examiners in the three characteristics of the aEEG. The k for the bedside neonatologist was very good for background pattern (k = 0.93), moderate (k = 0.52) for sleep-wake cycling, and weak (k = 0.32) for seizures. Conclusions: This study supports that background pattern is easily interpreted compared to sleep-wake cycling or crisis, improving when targeted training on aEEG is received. (c) 2022 Asociacion Espanola de Pediatria. Published by Elsevier Espana, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:416 / 421
页数:6
相关论文
共 50 条
[41]   Perinatal factors associated with amplitude-integrated electroencephalography abnormalities in preterm infants on the first day of life [J].
de Castro, Junia Sampel ;
Figueiredo Stochero Leslie, Ana Teresa ;
Guinsburg, Ruth .
JORNAL DE PEDIATRIA, 2020, 96 (05) :644-651
[42]   Amplitude-Integrated EEG for Neurological Assessment and Seizure Detection in a German Pediatric Intensive Care Unit [J].
Bruns, Nora ;
Sanchez-Albisua, Icier ;
Weiss, Christel ;
Tschiedel, Eva ;
Dohna-Schwake, Christian ;
Felderhoff-Mueser, Ursula ;
Mueller, Hanna .
FRONTIERS IN PEDIATRICS, 2019, 7
[43]   Continuous video recording with simultaneous amplitude-integrated EEG monitoring to improve seizure recognition in newborns [J].
Kage, Anup ;
Santana, Yesenia C. ;
Malcolm, Ivone L. ;
Francia, Caroline ;
Yoong, Michael ;
Wertheim, David ;
Shah, Divyen .
FRONTIERS IN PEDIATRICS, 2025, 13
[44]   Hypothermia for neonatal hypoxic-ischemic encephalopathy: may an early amplitude-integrated EEG improve the selection of candidates for cooling? [J].
Filippi, Luca ;
Catarzi, Serena ;
Gozzini, Elena ;
Fiorini, Patrizio ;
Falchi, Melania ;
Pisano, Tiziana ;
la Marca, Giancarlo ;
Donzelli, Gianpaolo ;
Guerrini, Renzo .
JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2012, 25 (11) :2171-2176
[45]   Agreement Between Long-Term Neonatal Background Classification by Conventional and Amplitude-Integrated EEG [J].
Clancy, Robert R. ;
Dicker, Lee ;
Cho, Sandy ;
Cook, Noah ;
Nicolson, Susan C. ;
Wernovsky, Gil ;
Spray, Thomas L. ;
Gaynor, J. William .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2011, 28 (01) :1-9
[46]   Effects of magnesium sulphate on amplitude-integrated continuous EEG in asphyxiated term neonates [J].
Groenendaal, F ;
Rademaker, CMA ;
Toet, MC ;
de Vries, LS .
ACTA PAEDIATRICA, 2002, 91 (10) :1073-1077
[47]   Sleep-wake cycle on amplitude-integrated EEG and neuroimage outcomes in newborns [J].
Seonkyeong Rhie ;
Kyu Young Chae ;
Heui Seung Jo ;
Kyu Hyung Lee .
Italian Journal of Pediatrics, 42
[48]   Automated classification of neonatal amplitude-integrated EEG based on gradient boosting method [J].
Yang, Tao ;
Chen, Weiting ;
Cao, Guitao .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 28 :50-57
[49]   Amplitude-integrated EEG and range-EEG modulation associated with pneumatic orocutaneous stimulation in preterm infants [J].
Barlow, S. M. ;
Jegatheesan, P. ;
Weiss, S. ;
Govindaswami, B. ;
Wang, J. ;
Lee, J. ;
Oder, A. ;
Song, D. .
JOURNAL OF PERINATOLOGY, 2014, 34 (03) :213-219
[50]   Comparison of conventional, amplitude-integrated and geodesic sensor net EEG used in premature neonates: a systematic review [J].
Alves de Sousa, Taina Maria ;
Gugelmin, Vinicius Siessere ;
Fernandes, Geraldo Magela ;
Aucelio, Carlos Nogueira ;
Costa, Karina Nascimento ;
Tristao, Rosana Maria .
ARQUIVOS DE NEURO-PSIQUIATRIA, 2019, 77 (04) :260-267