Inter-observer reliability for amplitude-integrated EEG in the newborn with perinatal asphyxia

被引:3
作者
Bustamante-Hervas, Carmen [1 ]
Valverde, Eva [2 ,3 ]
Vega-Del-Val, Cristina [1 ]
Schuffelmann, Susana [1 ]
Arnaez, Juan [1 ,3 ]
机构
[1] Complejo Asistencial Univ Burgos, Unidad Neonatol, Burgos, Spain
[2] Hosp Univ Infantil La Paz, Serv Neonatol, Madrid, Spain
[3] Fdn NeNe, Madrid, Spain
来源
ANALES DE PEDIATRIA | 2022年 / 96卷 / 05期
关键词
aEEG; Amplitude integrated electroencephalography; Perinatal asphyxia; Hypoxic-ischemic encephalopathy; Neonate; Concordance; ELECTROENCEPHALOGRAPHY;
D O I
10.1016/j.anpedi.2021.01.014
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Introduction: Amplitude integrated electroencephalography (aEEG) is a widely tool used for neuromonitoring in the critical neonate. In the patient with perinatal asphyxia, its interpretation is key to identifying candidates for therapeutic hypothermia, detecting subclinical seizures and providing pronostic information. Our aim was to analyze the concordance in the interpretation of aEEG among neonatologists with different level of experience. Material and methods: Unicenter retrospective study of newborns >= 35 weeks with perinatal asphyxia included consecutively over a two-year period and monitored with aEEG for at least 6 h. The bedside neonatologist interpreted aEEG regarding background pattern, sleep-wake cycling, and seizures. The aEEG tracings were blindly reviewed by two neonatologists with different experience. The aEEG tracings were divided into periods of 0-3 h and 3-6 h of life, and the concordance (Cohen Kappa coefficient, k), between the two examiners and that of their consensus with the bedside neonatologist, was analyzed. Results: Seventy-five newborns were included, 5 of them were not aEEG-monitored. 132 tracings were analyzed with a very good concordance between the two examiners in the three characteristics of the aEEG. The k for the bedside neonatologist was very good for background pattern (k = 0.93), moderate (k = 0.52) for sleep-wake cycling, and weak (k = 0.32) for seizures. Conclusions: This study supports that background pattern is easily interpreted compared to sleep-wake cycling or crisis, improving when targeted training on aEEG is received. (c) 2022 Asociacion Espanola de Pediatria. Published by Elsevier Espana, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:416 / 421
页数:6
相关论文
共 50 条
  • [21] Amplitude-integrated EEG use in neonatal abstinence syndrome: a pilot study
    Limjoco, Jamie
    Zawadzki, Lucyna
    Belden, Meghan
    Eickhoff, Jens
    Ikonomidou, Chrysanthy
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (21) : 3565 - 3570
  • [22] Clinical outcome prediction with an automated EEG trend, Brain State of the Newborn, after perinatal asphyxia
    Montazeri, Saeed
    Nevalainen, Paivi
    Metsaranta, Marjo
    Stevenson, Nathan J.
    Vanhatalo, Sampsa
    CLINICAL NEUROPHYSIOLOGY, 2024, 162 : 68 - 76
  • [23] A Comparison Of Conventional Electroencephalography With Amplitude-Integrated EEG In Detection Of Neonatal Seizures
    Kadivar, Maliheh
    Moghadam, Elahe Movahedi
    Badv, Reza Shervin
    Sangsari, Raziye
    Saeedy, Maryam
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2019, 12 : 489 - 496
  • [24] Prognostic value of amplitude-integrated EEG in neonates with high risk of neurological sequelae
    Yuan, Xiao
    Kang, Wenqing
    Song, Juan
    Guo, Jing
    Guo, Lanlan
    Zhang, Ruili
    Liu, Shasha
    Zhang, Yaodong
    Liu, Dapeng
    Wang, Yong
    Ding, Xue
    Dong, Huimin
    Chen, Xi
    Cheng, Yanchao
    Zhang, Xiaoli
    Xu, Falin
    Zhu, Changlian
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (02): : 210 - 218
  • [25] Mnemonics for the use and interpretation of amplitude-integrated electroencephalography in newborn infants
    Sanchez-Acosta, Cesar G.
    ARCHIVOS ARGENTINOS DE PEDIATRIA, 2024, 122 (04):
  • [26] An Amplitude-Integrated EEG Evaluation of Neonatal Opioid Withdrawal Syndrome
    Lust, Christopher
    Vesoulis, Zachary
    Zempel, John
    Gu, Hongjie
    Lee, Stephanie
    Rao, Rakesh
    Mathur, Amit M.
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e290 - e297
  • [27] Prediction of neonatal amplitude-integrated EEG based on LSTM method
    Liu, Lizhe
    Chen, Weiting
    Cao, Guitao
    2016 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2016, : 497 - 500
  • [28] Usefulness of two-channel amplitude-integrated EEG recording in a neonatal setting
    Arnaez, Juan
    Guillermo Sanchez-Acosta, Cesar
    Fasce, Juan
    Garcia-Alix, Alfredo
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2021, 34 (14) : 2248 - 2258
  • [29] Sleep-wake cycle on amplitude-integrated EEG and neuroimage outcomes in newborns
    Rhie, Seonkyeong
    Chae, Kyu Young
    Jo, Heui Seung
    Lee, Kyu Hyung
    ITALIAN JOURNAL OF PEDIATRICS, 2016, 42
  • [30] Domain Adaptation to Automatic Classification of Neonatal Amplitude-Integrated EEG
    Liu, Yang
    Chen, Weiting
    Yang, Su
    Huang, Kai
    2012 12TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND APPLICATIONS (ISDA), 2012, : 131 - 136