Biomechanical and electromyographic evaluation of ankle foot orthosis and dynamic ankle foot orthosis in spastic cerebral palsy

被引:78
|
作者
Lam, WK
Leong, JCY [1 ]
Li, YH
Hu, Y
Lu, WW
机构
[1] Univ Hong Kong, Queen Mary Hosp, Dept Orthopaed Surg, Hong Kong, Hong Kong, Peoples R China
[2] Duchess Kent Childrens Hosp, Hong Kong, Hong Kong, Peoples R China
关键词
ankle foot orthosis; electromyography; gait; cerebral palsy; spasticity;
D O I
10.1016/j.gaitpost.2004.09.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study evaluated the biomechanical and electromyographic effects of conventional ankle foot orthoses (AFOs) and dynamic ankle foot orthoses (DAFOs) on gait in patients with spastic cerebral palsy (CP). Thirteen patients with dynamic equinus underwent motion analysis with electromyography. Both AFOs and DAFOs provided longer stride length, permitted pre-positioning for initial contact, and successfully controlled the excessive plantarflexion during the swing phase. Median frequency (MF) of EMG signal indicated that extremely high firing was found in the patient's lower limbs compared to controls that resulted in tiredness. The DAFOs allowed a significantly larger total ankle range of motion than the AFOs. However, AFOs significantly reduced the MF while DAFOs did not. The reduced MF seen when wearing AFOs suggested an improvement of walking endurance. The DAFO had the advantage of less restriction on ankle movement, which avoids muscular atrophy and improves orthotic compliance. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [1] Moderate effect of ankle foot orthosis versus ground reaction ankle foot orthosis on balance in children with diplegic cerebral palsy
    Sanad, Doaa Ahmed
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2022, 46 (01) : 2 - 6
  • [2] Biomechanical Comparison of a New Dynamic Ankle Orthosis to a Standard Ankle-Foot Orthosis During Walking
    Chung, Chloe L.
    DiAngelo, Denis J.
    Powell, Douglas W.
    Paquette, Max R.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (05):
  • [3] HYDRAULIC ANKLE FOOT ORTHOSIS EMULATOR FOR CHILDREN WITH CEREBRAL PALSY
    Durfee, William
    Hashemi, Saeed
    Ries, Andrew
    PROCEEDINGS OF THE BATH/ASME 2020 SYMPOSIUM ON FLUID POWER AND MOTION CONTROL (FPMC2020), 2020,
  • [4] The effect of floor reaction ankle foot orthosis on postural control in children with spastic cerebral palsy
    Bahramizadeh, Mahmood
    Mousavi, Mohammad Ebrahim
    Rassafiani, Mehdi
    Aminian, Gholamreza
    Ebrahimi, Ismail
    Karimlou, Masoud
    O' Toole, Gjyn
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2012, 36 (01) : 71 - 76
  • [5] Acclimatization of the gait pattern to wearing an ankle-foot orthosis in children with spastic cerebral palsy
    Kerkum, Yvette L.
    Brehm, Merel-Anne
    van Hutten, Kim
    van den Noort, Josien C.
    Harlaar, Jaap
    Becher, Jules G.
    Buizer, Annemieke I.
    CLINICAL BIOMECHANICS, 2015, 30 (06) : 617 - 622
  • [6] Immediate effect of solid ankle foot orthosis versus ground reaction ankle foot orthosis on balance in children with spastic diplegia
    Sanad, Doaa Ahmed
    Ayoub, Hamada Ei-Sayed
    Abdelkader, Ahmed Mamdouh Mohamed
    BIOSCIENCE RESEARCH, 2018, 15 (04): : 2893 - 2898
  • [7] MULTIPHASIC ANKLE FOOT ORTHOSIS
    SCHLICHT, LA
    NEWTON, TJ
    BONFIGLIO, RP
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1988, 69 (09): : 794 - 794
  • [8] The effect of hinged ankle-foot orthosis on gait and energy expenditure in spastic hemiplegic cerebral palsy
    Balaban, Birol
    Yasar, Evren
    Dal, Ugur
    Yazicioglu, Kamil
    Mohur, Haydar
    Kalyon, Tunc Alp
    DISABILITY AND REHABILITATION, 2007, 29 (02) : 139 - 144
  • [9] KINEMATIC COMPARISON OF THE BICALL ANKLE FOOT ORTHOSIS AND THE RIGID POLYPROPYLENE ANKLE FOOT ORTHOSIS IN HEMIPLEGIA
    SMITH, AE
    QUIGLEY, M
    WATERS, RL
    PHYSICAL THERAPY, 1985, 65 (05): : 714 - 714