Polychromatic fingerprinting of excitation emission matrices

被引:25
作者
Gatto, Emanuela [2 ]
Malik, Muhammad A. [1 ]
Di Natale, Corrado [3 ]
Paolesse, Roberto [2 ]
D'Amico, Arnaldo [3 ]
Lundstroem, Ingemar [1 ]
Filippini, Daniel [1 ]
机构
[1] Linkoping Univ, IFM, Div Appl Phys, S-58183 Linkoping, Sweden
[2] Univ Roma Tor Vergata, Dept Chem Sci & Technol, I-00133 Rome, Italy
[3] Univ Roma Tor Vergata, Dept Elect Engn, I-00133 Rome, Italy
关键词
analytical methods; chemosensors; optical methods; porphyrinoids; sensors;
D O I
10.1002/chem.200800590
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The ability of a ubiquitous polychromatic excitation to support the fingerprinting of the Excitation Emission Matrices (EEM) of fluorescent indicators was reported. Solutions of fluorescent molecules, with concentration of 2μM for the absorption and 10μM for the emission measurements were prepared. Spectroscopic grade THF and distilled water passed through Milli-Q purification system were used as solvents. EEM measurements were carried out on a spectrofluorimeter, operating in the 390-700 nm detection range, with excitations at 20 nm intervals within the same range. During the measurement, the screen displayed a sequence of 50 colors and for every color, the transmission and emission spectrum of both the reference and the sample were recorded. Illuminating colors in the red region are not able to excite fluorescence and this can be seen in the spectra for red light.
引用
收藏
页码:6057 / 6060
页数:4
相关论文
共 23 条
[1]  
BENTLER P, 1995, STRUCTURAL EQUATION, P6
[2]  
Di Natale C., 2006, ANGEW CHEM, V118, P3884
[3]   Spectral characteristics of computer screen photoassisted classification [J].
Filippini, D. ;
Lundstrom, I. .
JOURNAL OF APPLIED PHYSICS, 2006, 99 (11)
[4]   Measurement strategy and instrumental performance of a computer screen photo-assisted technique for the evaluation of a multi-parameter colorimetric test strip [J].
Filippini, D ;
Lundström, I .
ANALYST, 2006, 131 (01) :111-117
[5]   Computer screen as a programmable light source for visible absorption characterization of (bio)chemical assays [J].
Filippini, D ;
Svensson, SPS ;
Lundström, I .
CHEMICAL COMMUNICATIONS, 2003, (02) :240-241
[6]   Chemical sensing with familiar devices [J].
Filippini, Daniel ;
Alimelli, Adriano ;
Di Natale, Corrado ;
Paolesse, Roberto ;
D'Amico, Arnaldo ;
Lundstrom, Ingemar .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (23) :3800-3803
[7]   Estuarine water classification using EEM spectroscopy and PARAFAC-SIMCA [J].
Hall, Gregory J. ;
Kenny, Jonathan E. .
ANALYTICA CHIMICA ACTA, 2007, 581 (01) :118-124
[8]   Light emitting diode excitation emission matrix fluorescence spectroscopy [J].
Hart, SJ ;
JiJi, RD .
ANALYST, 2002, 127 (12) :1693-1699
[9]   LIQUID-CHROMATOGRAPHY WITH REAL-TIME VIDEO FLUOROMETRIC MONITORING OF EFFLUENTS [J].
HERSHBERGER, LW ;
CALLIS, JB ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1981, 53 (07) :971-975
[10]   Cutoff Criteria for Fit Indexes in Covariance Structure Analysis: Conventional Criteria Versus New Alternatives [J].
Hu, Li-tze ;
Bentler, Peter M. .
STRUCTURAL EQUATION MODELING-A MULTIDISCIPLINARY JOURNAL, 1999, 6 (01) :1-55