Change in tensile properties of neoprene and nitrile gloves after repeated exposures to acetone and thermal decontamination

被引:10
作者
Gao, PF
Tomasovic, B
机构
[1] NIOSH, Natl Personal Protect Technol Lab, Pittsburgh, PA 15236 USA
[2] EG&G Tech Serv Inc, Pittsburgh, PA USA
关键词
acetone; chemical protective gloves; decontamination; degradation; tensile strength; ultimate elongation;
D O I
10.1080/15459620500315964
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the change in tensile properties of neoprene and nitrile gloves after repeated cycles of exposure to acetone, followed by thermal decontamination. The glove was exposed to acetone (outer surface in contact with chemical), subjected to thermal decontamination, and tested for the tensile strength and the ultimate elongation. Thermal decontamination was carried out inside an oven for 16 hours at 100 degrees C. The exposure/decontamination procedure was repeated for a maximum of 10 cycles. For neoprene versus acetone, the mean tensile strength consistently decreased after each exposure/decontamination cycle. Multiple comparisons indicated that the mean tensile strengths between the new swatches and each exposure/decontamination group were significantly different (p < 0.05). The loss of either tensile strength or ultimate elongation was less than 23% compared with new swatches after four exposure/decontamination cycles. Swatches without acetone exposure were then cycled through the oven in the same manner. It was found that both the heat used for thermal decontamination and acetone exposure significantly affected the tensile strength and ultimate elongation. For nitrile gloves exposed to acetone, the mean tensile strength remained virtually unchanged (p > 0.05). The mean tensile strength,for the new swatches was 37.1 MPa and the mean tensile strength after nine exposure/decontamination cycles was 36.0 MPa, with a loss less than 3%. The largest single cycle loss for ultimate elongation occurred during the first exposure/decontamination cycle for both glove materials. In our previous study, decisions regarding the effectiveness to the decontamination process were based on having no discernible change in the breakthrough time and steady-state permeation rate. The results of this study indicate that the effectiveness of the decontamination process cannot be based on permeation parameters alone but must also take into account the change in physical properties.
引用
收藏
页码:543 / 552
页数:10
相关论文
共 15 条
[1]  
*ASTM, 1999, 140799A ASTM F
[2]  
*ASTM, 1995, 54395 ASTM D
[3]  
*ASTM, 1998, 47198 ASTM D
[4]  
*ASTM, 1999, STAND GUID SEL CHEM
[5]  
COLETTA GC, 1988, AM IND HYG ASSOC J, V49, P26
[6]  
Douglas A, 1997, AM IND HYG ASSOC J, V58, P672, DOI 10.1202/0002-8894(1997)058<0672:BDOLAV>2.0.CO
[7]  
2
[8]   NEW TABLES FOR MULTIPLE COMPARISONS WITH CONTROL [J].
DUNNETT, CW .
BIOMETRICS, 1964, 20 (03) :482-&
[9]   Change in permeation parameters and the decontamination efficacy of three chemical protective gloves after repeated exposures to solvents and thermal decontaminations [J].
Gao, PF ;
El-Ayouby, N ;
Wassell, JT .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2005, 47 (02) :131-143
[10]  
*ISEA, 2000, 1052000 ANSI ISEA