Determination of 5-fluorocytosine, 5-fluorouracil, and 5-fluorouridine in hospital wastewater by liquid chromatography-mass spectrometry

被引:5
作者
Skvara, Pavel [1 ]
Santana-Viera, Sergio [2 ]
Montesdeoca-Esponda, Sarah [2 ]
Mordacikova, Erika [1 ]
Santana-Rodriguez, Jose Juan [2 ]
Vojs Stanova, Andrea [1 ,3 ]
机构
[1] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, Bratislava, Slovakia
[2] Univ Las Palmas Gran Canaria, Inst Estudios Ambientales & Recursos Nat I UNAT, Las Palmas Gran Canaria, Spain
[3] Univ South Bohemia Ceske Budejovice, Fac Fisheries & Protect Waters, South Bohemian Res Ctr Aquaculture & Biodivers Hy, Vodnany, Czech Republic
关键词
cytostatic compounds; sample pretreatment; tandem mass spectrometry; wastewater samples; SOLID-PHASE EXTRACTION; ANTICANCER DRUGS; CYTOSTATIC DRUGS; PHARMACEUTICALS; GENOTOXICITY; TOXICITY; SAMPLES; ENVIRONMENT; SYSTEM; FATE;
D O I
10.1002/jssc.202000144
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemotherapeutics are pharmaceutical compounds the occurrence of which in the environment is of growing concern because of the increase in treatments against cancer diseases. They can reach the aquatic ecosystems after passing through wastewater treatment plants without complete removal. One of the most frequently used chemotherapeutics is 5-fluorouracil which exhibits a strong cytostatic effect. In this paper, an analytical methodology was developed, validated, and applied to determine 5-fluorouracil, its precursor, 5-fluorocytosine, and its major active metabolite, 5-fluorouridine, in hospital wastewater samples. Due to the expected low concentrations after dilution and interferences present in such a complex matrix, a very selective and sensitive detection method is required. Moreover, an extraction method must be implemented prior to the determination in order to purify the sample extract and preconcentrate the target analytes at micrograms per liter concentration levels. Solid-phase extraction followed by liquid chromatography with tandem mass spectrometry was the combination of choice and all included parameters were studied. Under optimized conditions for wastewater samples analysis, recoveries from 63 to 108% were obtained, while intraday and interday relative standard deviations never exceeded 20 and 25%, respectively. Limits of detection between 61 and 620 ng/L were achieved. Finally, the optimized method was applied to samples from hospital wastewater effluents.
引用
收藏
页码:3074 / 3082
页数:9
相关论文
共 36 条
  • [1] Barker S. A., 2000, SOLID PHASE EXTRACTI
  • [2] Anticancer drugs in surface waters What can we say about the occurrence and environmental significance of cytotoxic, cytostatic and endocrine therapy drugs?
    Besse, Jean-Philippe
    Latour, Jean-Francois
    Garric, Jeanne
    [J]. ENVIRONMENT INTERNATIONAL, 2012, 39 (01) : 73 - 86
  • [3] Acute aquatic toxicity assessment of six anti-cancer drugs and one metabolite using biotest battery-Biological effects and stability under test conditions
    Bialk-Bielinska, Anna
    Mulkiewicz, Ewa
    Stokowski, Marcin
    Stolte, Stefan
    Stepnowski, Piotr
    [J]. CHEMOSPHERE, 2017, 189 : 689 - 698
  • [4] Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression
    Buhrman, DL
    Price, PI
    Rudewicz, PJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) : 1099 - 1105
  • [5] Dispersive solid-phase extraction procedure coupled to UPLC-ESI-MS/MS analysis for the simultaneous determination of thirteen cytotoxic drugs in human urine
    Fabrizi, Giovanni
    Fioretti, Marzia
    Rocca, Lucia Mainero
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (08) : 1297 - 1308
  • [6] Incidence of anticancer drugs in an aquatic urban system: From hospital effluents through urban wastewater to natural environment
    Ferrando-Climent, L.
    Rodriguez-Mozaz, S.
    Barcelo, D.
    [J]. ENVIRONMENTAL POLLUTION, 2014, 193 : 216 - 223
  • [7] Fischer J., 2006, ANALOGUE BASED DRUG
  • [8] Funk W., 2007, Quality Assurance in Analytical Chemistry, V2a
  • [9] Determination of pharmaceuticals of various therapeutic classes by solid-phase extraction and liquid chromatography-tandem mass spectrometry analysis in hospital effluent wastewaters
    Gomez, M. Jose
    Petrovic, Mira
    Fernandez-Alba, Amadeo R.
    Barcelo, Damia
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (02) : 224 - 233
  • [10] Multi-residue analytical methods using LC-tandem MS for the determination of pharmaceuticals in environmental and wastewater samples: a review
    Gros, Meritxell
    Petrovic, Mira
    Barcelo, Damia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (04) : 941 - 952