Development of polymeric membrane sensor for the determination of histamine: Experimental and theoretical study

被引:10
作者
Javanbakht, M. [1 ]
Ganjali, M. R. [2 ]
Norouzi, P. [2 ]
Abdouss, M. [1 ]
Riahi, S. [2 ]
机构
[1] Amir Kabir Univ Technol, Dept Chem, Tehran, Iran
[2] Univ Tehran, Ctr Excellence Electrochem, Fac Chem, Tehran, Iran
关键词
sensor; selective; membrane; histamine; potentiometric; thiopyrilium; ab initio calculation;
D O I
10.1080/00032710801910775
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Some original histamine membrane sensors were prepared by incorporating thiopyrilium (TP) derivative as an excellent charged carrier. Among these sensors, TP2 shows the best response to histamine in a wide concentration range from 2.5 x 10(-6) to 1.0 x 10(-1) mol L-1 with a slope of 55.6 +/- 0.7 mV decade(-1) and with a detection limit of 1.0 mu mol L-1 (similar to 0.1 ppm). The interference between histamine and several amino acids and common inorganic anions was negligible as shown by the potentiometric selectivity coefficient data. The prepared electrode was used for the determination of histamine in a human serum synthetic sample. Theoretical calculations were carried out to find the best interactions between histamine and different ligands.
引用
收藏
页码:619 / 639
页数:21
相关论文
共 49 条
[1]   Porphyrins as carriers in poly(vinyl chloride)-based membrane potentiometric sensors for histamine [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYST, 1999, 124 (09) :1319-1322
[2]   Comparison of ELISA and HPLC for the determination of histamine in cheese [J].
Aygün, O ;
Schneider, E ;
Scheuer, R ;
Usleber, E ;
Gareis, M ;
Märtlbauer, E .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (05) :1961-1964
[3]  
BAKKER E, 1997, CHEM REV, V97, P3087
[4]   Improved sensitivity of a histamine sensor using an engineered methylamine dehydrogenase [J].
Bao, LL ;
Sun, DP ;
Tachikawa, H ;
Davidson, VL .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1144-+
[5]   THE DEMONSTRATION OF HISTAMINE-RELEASE IN CLINICAL CONDITIONS - A REVIEW OF PAST AND PRESENT ASSAY PROCEDURES [J].
BEAVEN, MA ;
ROBINSONWHITE, A ;
RODERICK, NB ;
KAUFFMAN, GL .
KLINISCHE WOCHENSCHRIFT, 1982, 60 (17) :873-881
[6]   A SENSITIVE AND SPECIFIC RADIOMETRIC METHOD FOR THE MEASUREMENT OF PLASMA HISTAMINE IN NORMAL INDIVIDUALS [J].
BROWN, MJ ;
IND, PW ;
BARNES, PJ ;
JENNER, DA ;
DOLLERY, CT .
ANALYTICAL BIOCHEMISTRY, 1980, 109 (01) :142-146
[7]   Validation and comparison of analytical methods for the determination of histamine in tuna fish samples [J].
Cinquina, AL ;
Longo, F ;
Calì, A ;
De Santis, L ;
Baccelliere, R ;
Cozzani, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) :79-85
[8]   Vibrational dynamics of histamine monocation in solution:: an experimental (FT-IR, FT-Raman) and theoretical (SCRF-DFT) study [J].
Collado, JA ;
Tuñón, I ;
Silla, E ;
Ramírez, FJ .
JOURNAL OF PHYSICAL CHEMISTRY A, 2000, 104 (10) :2120-2131
[9]  
COOPER DG, 1990, COMPRENHENSIVE MED C, P3
[10]   FREE-ENERGY OF ASSOCIATION OF THE 18-CROWN-6-K+ COMPLEX IN WATER - A MOLECULAR-DYNAMICS SIMULATION [J].
DANG, LX ;
KOLLMAN, PA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (15) :5716-5720