Orthokeratology for myopic children: wolf in sheep's clothing?

被引:17
作者
Kwok, LS
Pierscionek, BK
Bullimore, M
Swarbrick, HA
Mountford, J
Sutton, G
机构
[1] Univ New S Wales, Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
[2] Univ Ulster, Dept Biomed Sci, Coleraine BT52 1SA, Londonderry, North Ireland
[3] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
[4] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[5] Inst Eye, Sydney, NSW, Australia
关键词
contact lens; keratitis; myopia; orthokeratology;
D O I
10.1111/j.1442-9071.2005.01059.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Orthokeratology attempts to reduce myopia by remoulding the corneal shape with contact lenses. A recent resurgence is predicated on new contact lens designs with a prefigured back contact surface and higher oxygen transmissibility. This Clinical Controversy presents an analysis of the risk factors associated with orthokeratology and its suitability for children, followed by commentaries from specialists who have an interest in the method. Some state that there is a lack of data on relative risks of corneal infection and that there is a need for large-scale randomized controlled studies; however, opinion is expressed by others that orthokeratology is a clinically safe procedure using modern lenses. It is noted that the physiological and biophysical bases of orthokeratology are virtually unknown, and further research on the human cornea is indicated to scientifically establish the safety of orthokeratology Prospective patients, and their parents in the case of children, should be fully informed of the risks.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 41 条
  • [31] THE IMPACT OF OVERNIGHT WEAR ON THE RISK OF CONTACT LENS-ASSOCIATED ULCERATIVE KERATITIS
    SCHEIN, OD
    BUEHLER, PO
    STAMLER, JF
    VERDIER, DD
    KATZ, J
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (02) : 186 - 190
  • [32] Seal D V, 1999, Cont Lens Anterior Eye, V22, P49, DOI 10.1016/S1367-0484(99)80003-4
  • [33] Change of proliferation rate of corneal epithelium in the rabbit with orthokeratology lens
    Shin, YJ
    Kim, MK
    Wee, WR
    Lee, JH
    Shin, DB
    Lee, JL
    Xu, YG
    Choi, SW
    [J]. OPHTHALMIC RESEARCH, 2005, 37 (02) : 94 - 103
  • [34] Solomon O. David, 1994, CLAO Journal, V20, P109
  • [35] SONI PS, 2003, EYE CONTACT LENS, V28, P137
  • [36] Acanthamoeba keratitis as a complication of orthokeratology
    Sun, XG
    Chen, L
    Zhang, Y
    Wang, ZQ
    Li, R
    Luo, SY
    Jin, XY
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (06) : 1159 - 1161
  • [37] Corneal response to orthokeratology
    Swarbrick, HA
    Wong, GT
    O'Leary, DJ
    [J]. OPTOMETRY AND VISION SCIENCE, 1998, 75 (11) : 791 - 799
  • [38] Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction
    Wang, JH
    Fonn, D
    Simpson, TL
    Sorbara, L
    Kort, R
    Jones, L
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (11) : 4742 - 4746
  • [39] Yeniad Baris, 2003, Eye Contact Lens, V29, P223, DOI 10.1097/01.icl.0000086494.50288.70
  • [40] Orthokeratology lens-related ulcers in children - Author reply
    Young, AL
    Fan, DSP
    Lam, DSC
    Qiu, JKK
    [J]. OPHTHALMOLOGY, 2005, 112 (01) : 168 - 169