Affordable pediatric CD4 counting by flow cytometry in Malawi

被引:4
作者
MacLennan, Calman A. [1 ,2 ,3 ,4 ,5 ]
Dzumani, Felix [6 ]
Namarika, Alinane [6 ]
Moons, Peter [7 ]
Senga, Edward [6 ]
Molyneux, Makohn E. [3 ]
Drayson, Mark T. [1 ,2 ]
Bunn, James E. G. [7 ,8 ]
机构
[1] Univ Birmingham, Inst Biomed Res, Med Res Council Ctr Immune Regulat, Birmingham B15 2TT, W Midlands, England
[2] Univ Birmingham, Inst Biomed Res, Div Immun & Infect, Clin Immunol Serv, Birmingham B15 2TT, W Midlands, England
[3] Univ Malawi, Coll Med, Malawi Liverpool Wellcome Trust Clin Res Programm, Blantyre, Malawi
[4] Univ Liverpool, Sch Infect & Host Def, Div Med Microbiol, Liverpool L69 3BX, Merseyside, England
[5] Univ Malawi, Coll Med, Dept Microbiol, Blantyre, Malawi
[6] Univ Malawi, Coll Med, Dept Biochem, Blantyre, Malawi
[7] Univ Malawi, Coll Med, Dept Pediat, Blantyre, Malawi
[8] Univ Malawi, Coll Med, Dept Community Hlth, Blantyre, Malawi
基金
英国惠康基金;
关键词
CD4 lymphocyte count; flow cytometry; Malawi; HIV; pediatrics;
D O I
10.1002/cyto.b.20411
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technology to transfer to government laboratories run by local staff, and to be validated in children, where %CD4/lymphocyte values are required. Methods: We assessed agreement of %CD4/lymphocyte values determined by the Blantyre count and Panleucogate methods on an EPICS XL-MCL flow cytometer on 113 venous blood samples from HIV-seropositive children in Blantyre, Malawi. All assays were performed by two Malawian laboratory technicians. Results: Overall bias between the two methods was -0.13% (95% CI -0.37 to 0.11) and limits of agreement were -2.69 to 2.43% (95% CI -3.11 to -2.27 and 2.01 to 2.85). Limits of agreement were within -3.00 and 3.00 for each laboratory technician. Coefficient of variation for the Blantyre count assay was 2.0% and samples showed good stability over 5 days. Conclusions: The Blantyre count method can accurately determine %CD4/lymphocyte values in blood of HIV-seropositive children on an EPIC XL-MCL flow cytometer at a reagent cost of US $0.21 per test or less. The assay can be competently carried out by local laboratory technicians. (C) 2008 Clinical Cytometry Society.
引用
收藏
页码:S90 / S97
页数:8
相关论文
共 50 条
[11]   Evaluation of the performances of the "MUSE AUTO CD4/CD4%" flow cytometer vs "GUAVA AUTO CD4/CD4%" flow cytometer for measuring the rate of CD4 lymphocytes in patients infected with HIV in Cameroon [J].
Kalla, Ginette Claude Mireille ;
Voundi, Esther Voundi ;
Tanghu, Florence Mimo ;
Sike, Christiane Medi ;
Noubom, Michel ;
Nkodo, Joseph Mendimi ;
Amougou, Justin ;
Ndjolo, Alexis ;
Mbopi-Keou, Francois-Xavier .
PAN AFRICAN MEDICAL JOURNAL, 2019, 32
[12]   Absolute CD4 count and percentage values among Libyan patients with HIV by single-platform flow cytometry [J].
Lamami, Yosra ;
Abulayha, Abdulmunem M. ;
Altabal, Salah ;
Elbasir, Mohamed ;
Elbnnani, Abdulrhman S. ;
Aghil, Laila ;
Ebrahim, Fawzi ;
Elzagheid, Adam .
LABORATORY MEDICINE, 2024, 55 (06) :763-767
[13]   Targeting CD4 testing to a clinical subgroup of patients could limit unnecessary CD4 measurements, premature antiretroviral treatment and costs in Thyolo District, Malawi [J].
Zachariah, R ;
Teck, R ;
Ascurra, O ;
Humblet, P ;
Harries, AD .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2006, 100 (01) :24-31
[14]   Validation of a single-platform, volumetric, flow cytometry for CD4 T cell count monitoring in therapeutic mobile unit [J].
François-Xavier Mbopi-Kéou ;
Bertrand Sagnia ;
Jeanne Ngogang ;
Fru F Angwafo III ;
Vittorio Colizzi ;
Luc Montagnier ;
Laurent Bélec .
Journal of Translational Medicine, 10
[15]   Validation of a single-platform, volumetric, flow cytometry for CD4 T cell count monitoring in therapeutic mobile unit [J].
Mbopi-Keou, Francois-Xavier ;
Sagnia, Bertrand ;
Ngogang, Jeanne ;
Angwafo, Fru F., III ;
Colizzi, Vittorio ;
Montagnier, Luc ;
Belec, Laurent .
JOURNAL OF TRANSLATIONAL MEDICINE, 2012, 10
[16]   Microfluidic Assays for CD4 T Lymphocyte Counting: A Review [J].
Meng, Zhuolun ;
Raji, Hassan ;
Kokabi, Mahtab ;
Zou, Deng ;
Chan, James ;
Liu, Qihao ;
Zhang, Ruifeng ;
Javanmard, Mehdi .
BIOSENSORS-BASEL, 2025, 15 (01)
[17]   Emerging technologies for point-of-care CD4 T-lymphocyte counting [J].
Boyle, David S. ;
Hawkins, Kenneth R. ;
Steele, Matthew S. ;
Singhal, Mitra ;
Cheng, Xuanhong .
TRENDS IN BIOTECHNOLOGY, 2012, 30 (01) :45-54
[18]   True volumetric counting of CD34+cells using flow cytometry [J].
Rico, Laura G. ;
Bardina, Jorge ;
Salvia, Roser ;
Ward, Michael D. ;
Bradford, Jolene A. ;
Petriz, Jordi .
JOURNAL OF IMMUNOLOGICAL METHODS, 2024, 527
[19]   CD4 estimating reagents in dry format are compatible with conventional flow cytometer; FACSCalibur for estimation of absolute CD4 count & percentages [J].
Thakar, Madhuri ;
Mahajan, Bharati ;
Joshi, Trupti ;
Sane, Suvarna ;
Paranjape, Ramesh .
INDIAN JOURNAL OF MEDICAL RESEARCH, 2013, 137 :346-355
[20]   Absolute CD4 T-Cell counting in resource-poor settings - Direct volumetric measurements versus bead-based clinical flow cytometry instruments [J].
Dieye, TN ;
Vereecken, C ;
Diallo, AA ;
Ondoa, P ;
Diaw, PA ;
Camara, M ;
Karam, F ;
Mboup, S ;
Kestens, L .
JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2005, 39 (01) :32-37