Affordable pediatric CD4 counting by flow cytometry in Malawi

被引:4
|
作者
MacLennan, Calman A. [1 ,2 ,3 ,4 ,5 ]
Dzumani, Felix [6 ]
Namarika, Alinane [6 ]
Moons, Peter [7 ]
Senga, Edward [6 ]
Molyneux, Makohn E. [3 ]
Drayson, Mark T. [1 ,2 ]
Bunn, James E. G. [7 ,8 ]
机构
[1] Univ Birmingham, Inst Biomed Res, Med Res Council Ctr Immune Regulat, Birmingham B15 2TT, W Midlands, England
[2] Univ Birmingham, Inst Biomed Res, Div Immun & Infect, Clin Immunol Serv, Birmingham B15 2TT, W Midlands, England
[3] Univ Malawi, Coll Med, Malawi Liverpool Wellcome Trust Clin Res Programm, Blantyre, Malawi
[4] Univ Liverpool, Sch Infect & Host Def, Div Med Microbiol, Liverpool L69 3BX, Merseyside, England
[5] Univ Malawi, Coll Med, Dept Microbiol, Blantyre, Malawi
[6] Univ Malawi, Coll Med, Dept Biochem, Blantyre, Malawi
[7] Univ Malawi, Coll Med, Dept Pediat, Blantyre, Malawi
[8] Univ Malawi, Coll Med, Dept Community Hlth, Blantyre, Malawi
基金
英国惠康基金;
关键词
CD4 lymphocyte count; flow cytometry; Malawi; HIV; pediatrics;
D O I
10.1002/cyto.b.20411
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technology to transfer to government laboratories run by local staff, and to be validated in children, where %CD4/lymphocyte values are required. Methods: We assessed agreement of %CD4/lymphocyte values determined by the Blantyre count and Panleucogate methods on an EPICS XL-MCL flow cytometer on 113 venous blood samples from HIV-seropositive children in Blantyre, Malawi. All assays were performed by two Malawian laboratory technicians. Results: Overall bias between the two methods was -0.13% (95% CI -0.37 to 0.11) and limits of agreement were -2.69 to 2.43% (95% CI -3.11 to -2.27 and 2.01 to 2.85). Limits of agreement were within -3.00 and 3.00 for each laboratory technician. Coefficient of variation for the Blantyre count assay was 2.0% and samples showed good stability over 5 days. Conclusions: The Blantyre count method can accurately determine %CD4/lymphocyte values in blood of HIV-seropositive children on an EPIC XL-MCL flow cytometer at a reagent cost of US $0.21 per test or less. The assay can be competently carried out by local laboratory technicians. (C) 2008 Clinical Cytometry Society.
引用
收藏
页码:S90 / S97
页数:8
相关论文
共 50 条
  • [11] Evaluation of the performances of the "MUSE AUTO CD4/CD4%" flow cytometer vs "GUAVA AUTO CD4/CD4%" flow cytometer for measuring the rate of CD4 lymphocytes in patients infected with HIV in Cameroon
    Kalla, Ginette Claude Mireille
    Voundi, Esther Voundi
    Tanghu, Florence Mimo
    Sike, Christiane Medi
    Noubom, Michel
    Nkodo, Joseph Mendimi
    Amougou, Justin
    Ndjolo, Alexis
    Mbopi-Keou, Francois-Xavier
    PAN AFRICAN MEDICAL JOURNAL, 2019, 32
  • [12] Absolute CD4 count and percentage values among Libyan patients with HIV by single-platform flow cytometry
    Lamami, Yosra
    Abulayha, Abdulmunem M.
    Altabal, Salah
    Elbasir, Mohamed
    Elbnnani, Abdulrhman S.
    Aghil, Laila
    Ebrahim, Fawzi
    Elzagheid, Adam
    LABORATORY MEDICINE, 2024, 55 (06) : 763 - 767
  • [13] Targeting CD4 testing to a clinical subgroup of patients could limit unnecessary CD4 measurements, premature antiretroviral treatment and costs in Thyolo District, Malawi
    Zachariah, R
    Teck, R
    Ascurra, O
    Humblet, P
    Harries, AD
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2006, 100 (01) : 24 - 31
  • [14] Validation of a single-platform, volumetric, flow cytometry for CD4 T cell count monitoring in therapeutic mobile unit
    François-Xavier Mbopi-Kéou
    Bertrand Sagnia
    Jeanne Ngogang
    Fru F Angwafo III
    Vittorio Colizzi
    Luc Montagnier
    Laurent Bélec
    Journal of Translational Medicine, 10
  • [15] Validation of a single-platform, volumetric, flow cytometry for CD4 T cell count monitoring in therapeutic mobile unit
    Mbopi-Keou, Francois-Xavier
    Sagnia, Bertrand
    Ngogang, Jeanne
    Angwafo, Fru F., III
    Colizzi, Vittorio
    Montagnier, Luc
    Belec, Laurent
    JOURNAL OF TRANSLATIONAL MEDICINE, 2012, 10
  • [16] Microfluidic Assays for CD4 T Lymphocyte Counting: A Review
    Meng, Zhuolun
    Raji, Hassan
    Kokabi, Mahtab
    Zou, Deng
    Chan, James
    Liu, Qihao
    Zhang, Ruifeng
    Javanmard, Mehdi
    BIOSENSORS-BASEL, 2025, 15 (01):
  • [17] Emerging technologies for point-of-care CD4 T-lymphocyte counting
    Boyle, David S.
    Hawkins, Kenneth R.
    Steele, Matthew S.
    Singhal, Mitra
    Cheng, Xuanhong
    TRENDS IN BIOTECHNOLOGY, 2012, 30 (01) : 45 - 54
  • [18] True volumetric counting of CD34+cells using flow cytometry
    Rico, Laura G.
    Bardina, Jorge
    Salvia, Roser
    Ward, Michael D.
    Bradford, Jolene A.
    Petriz, Jordi
    JOURNAL OF IMMUNOLOGICAL METHODS, 2024, 527
  • [19] CD4 estimating reagents in dry format are compatible with conventional flow cytometer; FACSCalibur for estimation of absolute CD4 count & percentages
    Thakar, Madhuri
    Mahajan, Bharati
    Joshi, Trupti
    Sane, Suvarna
    Paranjape, Ramesh
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2013, 137 : 346 - 355
  • [20] Absolute CD4 T-Cell counting in resource-poor settings - Direct volumetric measurements versus bead-based clinical flow cytometry instruments
    Dieye, TN
    Vereecken, C
    Diallo, AA
    Ondoa, P
    Diaw, PA
    Camara, M
    Karam, F
    Mboup, S
    Kestens, L
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2005, 39 (01) : 32 - 37