Affordable pediatric CD4 counting by flow cytometry in Malawi

被引:4
|
作者
MacLennan, Calman A. [1 ,2 ,3 ,4 ,5 ]
Dzumani, Felix [6 ]
Namarika, Alinane [6 ]
Moons, Peter [7 ]
Senga, Edward [6 ]
Molyneux, Makohn E. [3 ]
Drayson, Mark T. [1 ,2 ]
Bunn, James E. G. [7 ,8 ]
机构
[1] Univ Birmingham, Inst Biomed Res, Med Res Council Ctr Immune Regulat, Birmingham B15 2TT, W Midlands, England
[2] Univ Birmingham, Inst Biomed Res, Div Immun & Infect, Clin Immunol Serv, Birmingham B15 2TT, W Midlands, England
[3] Univ Malawi, Coll Med, Malawi Liverpool Wellcome Trust Clin Res Programm, Blantyre, Malawi
[4] Univ Liverpool, Sch Infect & Host Def, Div Med Microbiol, Liverpool L69 3BX, Merseyside, England
[5] Univ Malawi, Coll Med, Dept Microbiol, Blantyre, Malawi
[6] Univ Malawi, Coll Med, Dept Biochem, Blantyre, Malawi
[7] Univ Malawi, Coll Med, Dept Pediat, Blantyre, Malawi
[8] Univ Malawi, Coll Med, Dept Community Hlth, Blantyre, Malawi
基金
英国惠康基金;
关键词
CD4 lymphocyte count; flow cytometry; Malawi; HIV; pediatrics;
D O I
10.1002/cyto.b.20411
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Rapid expansion of antiretroviral therapy in Malawi has occurred in the relative absence of suitable pediatric CD4 counting facilities. We have recently validated in adults a simplified affordable flow cytometric CD4 counting method, the Blantyre count. There is a need for this technology to transfer to government laboratories run by local staff, and to be validated in children, where %CD4/lymphocyte values are required. Methods: We assessed agreement of %CD4/lymphocyte values determined by the Blantyre count and Panleucogate methods on an EPICS XL-MCL flow cytometer on 113 venous blood samples from HIV-seropositive children in Blantyre, Malawi. All assays were performed by two Malawian laboratory technicians. Results: Overall bias between the two methods was -0.13% (95% CI -0.37 to 0.11) and limits of agreement were -2.69 to 2.43% (95% CI -3.11 to -2.27 and 2.01 to 2.85). Limits of agreement were within -3.00 and 3.00 for each laboratory technician. Coefficient of variation for the Blantyre count assay was 2.0% and samples showed good stability over 5 days. Conclusions: The Blantyre count method can accurately determine %CD4/lymphocyte values in blood of HIV-seropositive children on an EPIC XL-MCL flow cytometer at a reagent cost of US $0.21 per test or less. The assay can be competently carried out by local laboratory technicians. (C) 2008 Clinical Cytometry Society.
引用
收藏
页码:S90 / S97
页数:8
相关论文
共 50 条
  • [1] Validation of primary CD4 gating as an affordable strategy for absolute CD4 counting in Cambodia
    Lynen, Lut
    Teavc, Syna
    Vereecken, Chris
    De Munter, Paul
    An, Sokkab
    Jacques, Gary
    Kestens, Luc
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2006, 43 (02) : 179 - 185
  • [2] Evaluation of a flow cytometry method for CD4 T cell enumeration based on volumetric primary CD4 gating using thermoresistant reagents
    Dieye, Tandakha Ndiaye
    Diaw, Papa Alassane
    Daneau, Geraldine
    Wade, Djibril
    Niang, Maguette Sylla
    Camara, Makhtar
    Diallo, Abdoul Aziz
    Kane, Coumba Toure
    Ndiaye, Halimatou Diop
    Mbengue, Babacar
    Dieye, Alioune
    Kestens, Luc
    Mboup, Souleymane
    JOURNAL OF IMMUNOLOGICAL METHODS, 2011, 372 (1-2) : 7 - 13
  • [3] Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry
    Koyalta, Donato
    Jenabian, Mohammad-Ali
    Djouater, Barou
    Djemadji-Oudjeil, Noel
    Mbopi-Keou, Francois-Xavier
    Ndjoyi-Mbiguino, Angelique
    Belec, Laurent
    BMC HEALTH SERVICES RESEARCH, 2013, 13
  • [4] Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry
    Donato Koyalta
    Mohammad-Ali Jenabian
    Barou Djouater
    Noël Djemadji-Oudjeil
    Francois-Xavier Mbopi-Keou
    Angélique Ndjoyi-Mbiguino
    Laurent Bélec
    BMC Health Services Research, 13
  • [5] A new polymorphic epitope of bovine CD4 antigen evidenced by flow cytometry
    Grandoni, Francesco
    Napolitano, Francesco
    Scata, Maria Carmela
    De Matteis, Giovanna
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2020, 219
  • [6] Thirty-Five Years of CD4 T-Cell Counting in HIV Infection: From Flow Cytometry in the Lab to Point-of-Care Testing in the Field
    Kestens, L.
    Mandy, F.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2017, 92 (06) : 437 - 444
  • [7] Quantifying CD4 receptor protein in two human CD4+ lymphocyte preparations for quantitative flow cytometry
    Meiyao Wang
    Martin Misakian
    Hua-Jun He
    Peter Bajcsy
    Fatima Abbasi
    Jeffrey M Davis
    Kenneth D Cole
    Illarion V Turko
    Lili Wang
    Clinical Proteomics, 2014, 11
  • [8] Automated cell count in flow cytometry -: A valuable tool to assess CD4 absolute levels in peripheral blood
    Béné, MC
    Sarda, MNK
    El Kaissouni, J
    Kennel, AD
    Molé, C
    Kohler, C
    Faure, GC
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (03) : 321 - 326
  • [9] Quantifying CD4 receptor protein in two human CD4+lymphocyte preparations for quantitative flow cytometry
    Wang, Meiyao
    Misakian, Martin
    He, Hua-Jun
    Bajcsy, Peter
    Abbasi, Fatima
    Davis, Jeffrey M.
    Cole, Kenneth D.
    Turko, Illarion V.
    Wang, Lili
    CLINICAL PROTEOMICS, 2014, 11
  • [10] Determination of CD4 lymphocyte percentages using a new simplified and affordable no lyse flow cytometric protocol: a pilot study
    Greve, Burkhard
    Cassens, Uwe
    Baumann, Claudia
    Sibrowski, Walter
    Kuling, Gudrun
    Szabados, Florian
    Schlenke, Peter
    Reichelt, Doris
    Gebauer, Wolfgang
    Goehde, Wolfgang
    LABORATORIUMSMEDIZIN-JOURNAL OF LABORATORY MEDICINE, 2008, 32 (03): : 182 - 189