Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography

被引:23
作者
Ender, J. [1 ]
Eibel, S. [1 ]
Mukherjee, C. [1 ]
Mathioudakis, D. [1 ]
Borger, M. A. [2 ]
Jacobs, S. [3 ]
Mohr, F. W. [2 ]
Falk, V. [3 ]
机构
[1] Univ Leipzig, Leipzig Heart Ctr, Dept Anaesthesiol & Intens Care Med 2, D-04289 Leipzig, Germany
[2] Univ Leipzig, Leipzig Heart Ctr, Dept Cardiac Surg, D-04289 Leipzig, Germany
[3] Univ Zurich, Clin Cardiac Surg, Zurich, Switzerland
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2011年 / 12卷 / 06期
关键词
Real-time three-dimensional echocardiography; Transoesophageal echocardiography; Mitral valve repair; Intercommissural distance; Anterior mitral leaflet; Annuloplasty ring; REGURGITATION; DISEASE;
D O I
10.1093/ejechocard/jer042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We sought to investigate the additional value of real-time three-dimensional transoesophageal echocardiography (RT 3D TOE)-guided sizing for predicting annuloplasty ring size during mitral valve repair. Methods and results In 53 patients undergoing elective mitral valve repair, an RT 3D TOE was performed pre- and post-operatively. The digitally stored loops were imported into a software for mitral valve assessment. The annuloplasty ring size was predicted by superimposing computer-aided design (CAD) models of annuloplasty rings onto Live 3D zoom loops, measurement of the intercommissural distance, or the height of the anterior mitral leaflet. The surgeon implanted the annuloplasty ring according to the usual surgical technique and was blinded to the echocardiographic measurement results. Pre-operative correlation between the selected ring size with mitral valve assessment and the actual implanted annuloplasty ring size was 0.91. The correlation for measurement of the intercommissural distance was 0.55 and for measurement of the height of the anterior mitral leaflet 0.75. The post-operative correlation with the actual implanted ring size was 0.96 for mitral valve assessment, 0.92 for intercommissural distance, and 0.79 for the anterior mitral leaflet height. Conclusion Superimposition of annuloplasty ring CAD models on the Live 3D zoom loops of the mitral valve using mitral valve assessment is superior to two-dimensional measurements of the intercommissural distance or the height of the anterior mitral leaflet in predicting correct annuloplasty ring size.
引用
收藏
页码:445 / 453
页数:9
相关论文
共 12 条
[1]   Accuracy of real-time 3D echocardiography in the evaluation of functional anatomy of mitral regurgitation [J].
Agricola, Eustachio ;
Oppizzi, Michele ;
Pisani, Matteo ;
Maisano, Francesco ;
Margonato, Alberto .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 127 (03) :342-349
[2]  
CARPENTIER A, 1971, J THORAC CARDIOV SUR, V61, P1
[3]  
Cook RC, 2006, J HEART VALVE DIS, V15, P524
[4]   A comparison of outcomes of mitral valve repair for degenerative disease with posterior, anterior, and bileaflet prolapse [J].
David, TE ;
Ivanov, J ;
Armstrong, S ;
Christie, D ;
Rakowski, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (05) :1242-1249
[5]   Value of Augmented Reality-Enhanced Transesophageal Echocardiography (TEE) for Determining Optimal Annuloplasty Ring Size During Mitral Valve Repair [J].
Ender, Joerg ;
Koncar-Zeh, Jasmina ;
Mukherjee, Chirojit ;
Jacobs, Stephan ;
Borger, Michael A. ;
Viola, Christoph ;
Gessat, Michael ;
Fassl, Jens ;
Mohr, Friedrich W. ;
Falk, Volkmar .
ANNALS OF THORACIC SURGERY, 2008, 86 (05) :1473-1479
[6]   Quantitative determinants of the outcome of asymptomatic mitral regurgitation [J].
Enriquez-Sarano, M ;
Avierinos, JF ;
Messika-Zeitoun, D ;
Detaint, D ;
Capps, M ;
Nkomo, V ;
Scott, C ;
Schaff, HV ;
Tajik, AJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (09) :875-883
[7]   Real-Time 3-Dimensional Transesophageal Echocardiography in the Evaluation of Post-Operative Mitral Annuloplasty Ring and Prosthetic Valve Dehiscence [J].
Kronzon, Itzhak ;
Sugeng, Lissa ;
Perk, Gila ;
Hirsh, David ;
Weinert, Lynn ;
Fernandez, Miguel Angel Garcia ;
Lang, Roberto M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (17) :1543-1547
[8]   Improved evaluation of the location and mechanism of mitral valve regurgitation with a systematic transesophageal echocardiography examination [J].
Lambert, AS ;
Miller, JP ;
Merrick, SH ;
Schiller, NB ;
Foster, E ;
Muhiudeen-Russell, I ;
Cahalan, MK .
ANESTHESIA AND ANALGESIA, 1999, 88 (06) :1205-1212
[9]   Gore-Tex Chordoplasty in Degenerative Mitral Valve Repair [J].
Seeburger, Joerg ;
Kuntze, Thomas ;
Mohr, Friedrich W. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2007, 19 (02) :111-115
[10]   ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination:: Recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography [J].
Shanewise, JS ;
Cheung, AT ;
Aronson, S ;
Stewart, WJ ;
Weiss, RL ;
Mark, JB ;
Savage, RM ;
Sears-Rogan, P ;
Mathew, JP ;
Quiñones, MA ;
Cahalan, MK ;
Savino, JS .
ANESTHESIA AND ANALGESIA, 1999, 89 (04) :870-884