The Effect of Surface Roughness on Corona-generated Electromagnetic Interference for Long-term Operating Conductors

被引:13
|
作者
Bian, Xingming [1 ,2 ,3 ]
Wang, Yuanjiu [4 ]
Wang, Liming [4 ]
Guan, Zhicheng [4 ]
Wan, Shuwei [5 ]
Chen, Lan [6 ]
Chen, Fangdong [6 ]
Zhao, Xuesong [6 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Beijing Key Lab High Voltage, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, EMC, Beijing 102206, Peoples R China
[4] Tsinghua Univ, Grad Sch Shenzhen, Shenzhen 518055, Guangdong, Peoples R China
[5] State Grid Chongqing Nanan Power Supply Co, Chongqing 400060, Peoples R China
[6] Jibei Elect Power Co Ltd, Beiijing 100053, Peoples R China
基金
中国国家自然科学基金;
关键词
AC corona discharge; electromagnetic interference; long-term operating conductor; surface condition; roughness; corona cage; VOLTAGE TRANSMISSION-LINES; RADIO-INTERFERENCE; INCEPTION VOLTAGES; AUDIBLE NOISE; FIELD; PREDETERMINATION; DISCHARGE; PERFORMANCE; PRESSURES; LEVEL;
D O I
10.1109/TDEI.2015.7076788
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a research of the surface roughness effects on corona-generated electromagnetic interference of long-term operating conductors. The detailed surface morphologies and roughness of typical long-term operating conductors were measured and analyzed. The radio noise measurement system based on the corona cage was discussed and the actual radio noise generated by the conductor in the measured cage was obtained, based on the parameters of the corona cage and the measured data. The radio noise tests were carried out under both dry and wet conditions. Under two types of conditions, the corona intensity was higher on the long-term operating conductors contrasted to the new conductors as a result of the anomalistic surfaces of the long-term operating conductors. The rate of decrease of corona inception voltages between the long-term operating conductors and new conductors was discovered to increase with the raise of surface roughness degree R-a in linear relationship. Approximate linear relation was also discovered between the averaged radio noise deviation and R-a. The rate of decrease of corona inception voltages under wet conditions was slightly higher (about 1%) than that under dry conditions. The difference between the radio noise of long-term operating conductors and that of new conductors was larger (1.3 dB) under wet conditions compared to dry conditions.
引用
收藏
页码:879 / 887
页数:9
相关论文
共 50 条
  • [1] Surface roughness effects on corona-generated radio noise for long-term operating conductors
    Bian, Xingming
    Zhuan, Shunxu
    Wan, Shuwei
    Liu, Lin
    Wang, Liming
    Duan, Bin
    Qu, Kaifeng
    Guan, Zhicheng
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2014, : 1107 - 1111
  • [2] Surface roughness effects on the corona discharge intensity of long-term operating conductors
    Bian, X. M.
    Chen, L.
    Yu, D. M.
    Wang, L. M.
    Guan, Z. C.
    APPLIED PHYSICS LETTERS, 2012, 101 (17)
  • [3] Comparative study on corona-generated audible noise and radio noise of ac long-term operating conductors with two bundle types
    Bian, Xingming
    Chen, Lan
    Zhao, Xuesong
    Chen, Fangdong
    Ji, Jianfei
    Wan, Shuwei
    Wang, Liming
    JOURNAL OF ELECTROSTATICS, 2015, 74 : 47 - 55
  • [4] The Evaluation Method of Surface Roughness Degree for Long-Term Operating Conductors Based on Gray Value Matrix
    Liu, Lin
    Bian, Xingming
    Cao, Lu
    Zhuansun, Xu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1641 - 1643
  • [5] Variation of corona effects for long-term operated conductors in AC power transmission lines
    Bian, X. (bianxm12@mail.tsinghua.edu.cn), 1600, Science Press (39):
  • [6] Corona Phenomena for Long-term Operating Conductor under Different Weather Conditions
    Chen, Lan
    Chen, Fangdong
    Song, Wei
    Zi, Xiandao
    Wang, Yuanjiu
    Bian, Xingming
    Wang, Liming
    Guan, Zhicheng
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 156 - 159
  • [7] Conductor Surface Conditions Effects on the Ion-Flow Field of Long-Term Operating Conductors of the HVDC Transmission Line
    Yi, Yong
    Zhang, Chuyan
    Wang, Liming
    Chen, Zhengying
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (05) : 2171 - 2178
  • [8] Impact of Surface Roughness on Corona Discharge for 30-year Operating Conductors in 500-kV ac Power Transmission Line
    Bian, Xingming
    Chen, Lan
    Yu, Deming
    Wang, Liming
    Guan, Zhicheng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (03) : 1693 - 1695
  • [9] LONG-TERM INTERFERENCE EFFECT - ALTERNATIVE TO LEARNED HELPLESSNESS
    GLAZER, HI
    WEISS, JM
    JOURNAL OF EXPERIMENTAL PSYCHOLOGY-ANIMAL BEHAVIOR PROCESSES, 1976, 2 (03): : 202 - 213
  • [10] RADIO INTERFERENCE LONG-TERM RECORDING ON AN OPERATING 420-KV LINE
    CORTINA, R
    SERRAVAL.W
    SFORZINI, M
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (05): : 881 - &