Biosensor for L-phenylalanine based on the optical detection of NADH using a UV light emitting diode

被引:29
作者
Arakawa, Takahiro [1 ]
Koshida, Tomoyuki [2 ]
Gessei, Tomoko [1 ,3 ]
Miyajima, Kumiko [1 ]
Takahashi, Daishi [1 ]
Kudo, Hiroyuki [1 ]
Yano, Kazuyoshi [2 ]
Mitsubayashi, Kohji [1 ]
机构
[1] Tokyo Med & Dent Univ, Dept Biomed Devices & Instrumentat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[2] Tokyo Univ Technol, Grad Sch Bion Comp & Media Sci, Tokyo 1920982, Japan
[3] Tokyo Metropolitan Ind Technol Res Inst, Kita Ku, Tokyo 1158586, Japan
基金
日本学术振兴会; 日本科学技术振兴机构;
关键词
Optical biosensor; L-phenylalanine; Ultraviolet light-emitting diodes excitation; Phenylalanine dehydrogenase; NADH; SYRUP-URINE-DISEASE; DRIED BLOOD-SPOT; BIO-SNIFFER; LED ARRAYS; 340; NM; DEHYDROGENASE; SENSOR; CHROMATOGRAPHY; PHENYLKETONURIA; HOMOCYSTINURIA;
D O I
10.1007/s00604-010-0536-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor was developed for the detection of L-phenylalanine (Phe) and demonstrated for use in the diagnosis of phenylketonuria (PKU). It consists of L-phenylalanine dehydrogenase (L-PheDH) immobilized on a membrane, an ultraviolet light-emitting diode excitation system, and a photo multiplier tube. The L-PheDH was immobilized on a teflon membrane modified with 2-methacryloyloxyethyl phosphorylcholine and placed at the distal and of an optical fiber. The concentration of Phe was determined by immersing the sensor into a sample solution that also contained NAD(+) and measurement of the fluorescence of the NADH produced by enzymatic reaction. Two L-PheDHs (from Thermoactinomyces intermedius and Sporosarcina sp.) were studied and compared. The fluorescence intensities of the biosensor are linearly related to the L-Phe concentrations in the range from 10 mu mol L-1 to 10 mmol L-1. The sensor also was operated in the kinetic mode by differential determination of the slope of the signal within 2 min. The analytical range of the sensor is adequate for application in the genotypic diagnosis of PKU (diagnostic value > 600 mu mol L-1). High sensitivity, good cost-benefit ratio, and low power consumption are typical features of this biosensing system that can can be applied to routine screening of newborn.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 33 条
[1]   Newborn screening of homocystinuria: quantitative analysis of total homocyst(e)ine on dried blood spot by liquid chromatography with fluorimetric detection [J].
Accinni, R ;
Campolo, J ;
Parolini, M ;
De Maria, R ;
Caruso, R ;
Maiorana, A ;
Galluzzo, C ;
Bartesaghi, S ;
Melotti, D ;
Parodi, O .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02) :219-226
[2]   Application of amperometric biosensors to the determination of vitamins and α-amino acids [J].
Alaejos, MS ;
Montelongo, FJG .
CHEMICAL REVIEWS, 2004, 104 (07) :3239-3265
[3]   Disorders of Fatty Acid Oxidation in the Era of Tandem Mass Spectrometry in Newborn Screening [J].
Banta-Wright, Sandra A. ;
Shelton, Kathleen C. ;
Bennett, Michael J. .
NEWBORN AND INFANT NURSING REVIEWS, 2008, 8 (01) :18-29
[4]   Maple syrup urine disease in treated patients: Biochemical and oxidative stress profiles [J].
Barschak, Alethea G. ;
Marchesan, Christiane ;
Sitta, Angela ;
Deon, Marion ;
Giugliani, Roberto ;
Wajner, Moacir ;
Vargas, Carmen Regla .
CLINICAL BIOCHEMISTRY, 2008, 41 (4-5) :317-324
[5]   A fluorescent chemical sensor for ethanol determination in alcoholic beverages [J].
Bozkurt, Serap Seyhan ;
Merdivan, Erinc ;
Benibol, Yalim .
MICROCHIMICA ACTA, 2010, 168 (1-2) :141-145
[6]   Neonatal biochemical screening for disease [J].
Clague, A ;
Thomas, A .
CLINICA CHIMICA ACTA, 2002, 315 (1-2) :99-110
[7]   Diazonium-functionalized tyrosinase-based biosensor for the detection of tea polyphenols [J].
Cortina-Puig, Montserrat ;
Munoz-Berbel, Xavier ;
Calas-Blanchard, Carole ;
Marty, Jean-Louis .
MICROCHIMICA ACTA, 2010, 171 (1-2) :187-193
[8]   UV LED arrays at 280 and 340 nm for spectroscopic biosensing [J].
Davitt, K. ;
Song, Y.-K. ;
Patterson, W. ;
Nurmikko, A. V. ;
Rer, Z. ;
Sun, Q. ;
Han, J. .
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2007, 204 (06) :2112-2116
[9]   290 and 340 nm UV LED arrays for fluorescence detection from single airborne particles [J].
Davitt, K ;
Song, YK ;
Patterson, WR ;
Nurmikko, AV ;
Gherasimova, M ;
Han, J ;
Pan, YL ;
Chang, RK .
OPTICS EXPRESS, 2005, 13 (23) :9548-9555
[10]   Diagnosis of maple syrup urine disease by determination of L-valine, L-isoleucine, L-leucine and L-phenylalanine in neonatal blood spots by gas chromatography-mass spectrometry [J].
Deng, CH ;
Deng, YH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02) :261-268