Three-dimensional surface imaging for detection of intra-fraction setup variations during radiotherapy of pelvic tumors

被引:10
作者
Apicella, Giuseppina [1 ]
Loi, Gianfranco [2 ]
Torrente, Sara [1 ]
Crespi, Silvia [1 ]
Beldi, Debora [1 ]
Brambilla, Marco [2 ]
Krengli, Marco [1 ,3 ]
机构
[1] Univ Hosp Maggiore della Carita, Div Radiotherapy, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Med Phys, Novara, Italy
[3] Univ Piemonte Orientale, Dept Translat Med, Novara, Italy
来源
RADIOLOGIA MEDICA | 2016年 / 121卷 / 10期
关键词
Radiotherapy; Surface imaging; Intrafraction; Setup; Organ motion; IGRT; INTRAFRACTION MOTION; CLINICAL-EXPERIENCE; RADIATION-THERAPY; PROSTATE-CANCER; PATIENT SETUP; BREATH-HOLD; SYSTEM; REPRODUCIBILITY; ALIGNMENT; ACCURACY;
D O I
10.1007/s11547-016-0659-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Surface-based image guided radiotherapy (IGRT) allows positioning and/or monitoring patients in 3 dimensions (3D), without the use of ionizing radiation. In this study, we report on intra-fraction motion measured by acquisition of multiple images of 3D body surfaces. Twenty-nine patients treated for pelvic tumors were enrolled. Setup variations (SV) through three consecutive body surfaces acquired by the optical IGRT system Align-RT (Vision-RT, London, UK) were analyzed before, during and at the end of treatment delivery. Displacements along the main axes (X, Y and Z) from initial (I) to mid-treatment (MT) and final (F) acquisitions were recorded. Time and direction of SV were assessed. A total of 6272 images from 792 fractions of 29 patients were available. The main source of misalignment was between I and MT acquisition (p < 0.001). The dominant SV direction was the vertical one (Z axis), with mean SV of -1.20 +/- A 0.06 mm and -1.55 +/- A 0.06 mm for I-MT and I-F acquisitions, respectively. The Y mean components of SV were, respectively, -0.95 +/- A 0.10 mm and -1.0 +/- A 0.10 for I-MT and I-F acquisitions, while the X deviations were 0.07 +/- A 0.08 mm for I-MT and 0.26 +/- A 0.08 mm I-F. Three-D surface imaging for patient setup monitoring highlighted remarkable mobility of patients during RT session, especially in the anterior-posterior direction (Z axis). The largest magnitude in patient movements occurred during the first part of delivery. These findings suggest that the initial setup control cannot not to be sufficient to guarantee treatment reproducibility, especially for long-lasting RT treatments.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 17 条
[1]   Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy [J].
Alderliesten, Tanja ;
Sonke, Jan-Jakob ;
Betgen, Anja ;
Honnef, Joeri ;
van Vliet-Vroegindeweij, Corine ;
Remeijer, Peter .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02) :536-542
[2]   Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients [J].
Bert, C ;
Metheany, KG ;
Doppke, KP ;
Taghian, AG ;
Powell, SN ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04) :1265-1274
[3]  
Britton Keith R, 2005, Radiat Med, V23, P14
[4]   Intrafractional prostate motion during online image guided intensity-modulated radiotherapy for prostate cancer [J].
Budiharto, Tom ;
Slagmolen, Pieter ;
Haustermans, Karin ;
Maes, Frederik ;
Junius, Sara ;
Verstraete, Jan ;
Oyen, Raymond ;
Hermans, Jeroen ;
Van den Heuvel, Frank .
RADIOTHERAPY AND ONCOLOGY, 2011, 98 (02) :181-186
[5]   Detection of setup uncertainties with 3D surface registration system for conformal radiotherapy of breast cancer [J].
Deantonio, Letizia ;
Masini, Laura ;
Loi, Gianfranco ;
Gambaro, Giuseppina ;
Bolchini, Cesare ;
Krengli, Marco .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2011, 16 (03) :77-81
[6]   Intrafraction motion of the prostate during external-beam radiation therapy: Analysis of 427 patients with implanted fiducial markers [J].
Kotte, Alexis N. T. J. ;
Hofman, Pieter ;
Lagendijk, Jan J. W. ;
van Vulpen, Marco ;
van der Heide, Uulke A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02) :419-425
[7]  
Krengli M, 2009, RADIAT ONCOL, V4, DOI [10.1186/1748-717X-4-9, 10.1186/1748-717X-5-10]
[8]   Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy [J].
Kupelian, Patrick ;
Willoughby, Twyla ;
Mahadevan, Arul ;
Djemil, Toufik ;
Weinstein, Geoffrey ;
Jani, Shirish ;
Enke, Charles ;
Solberg, Timothy ;
Flores, Nicholas ;
Liu, David ;
Beyer, David ;
Levine, Lisa .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1088-1098
[9]  
Langsenlehner T, 2013, STRAHLENTHER ONKOL, V189, P321, DOI 10.1007/s00066-012-0303-0
[10]   GAINS FROM REAL-TIME TRACKING OF PROSTATE MOTION DURING EXTERNAL BEAM RADIATION THERAPY [J].
Li, Jin Sheng ;
Jin, Lihui ;
Pollack, Alan ;
Horwitz, Eric M. ;
Buyyounouski, Mark K. ;
Price, Robert A., Jr. ;
Ma, Chang-Ming .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05) :1613-1620