Detection of coronary stenoses at rest with myocardial contrast echocardiography

被引:28
作者
Wei, K
Tong, KL
Belcik, T
Rafter, P
Ragosta, M
Wang, XQ
Kaul, S
机构
[1] Univ Virginia, Cardivasc Imaging Ctr, Div Cardiovasc, Dept Med, Charlottesville, VA USA
[2] Univ Virginia, Dept Hlth Evaluat Sci, Div Biostat & Epidemiol, Charlottesville, VA USA
[3] Philips Ultrasound, Andover, MA USA
关键词
contrast media; coronary disease; diagnosis; echocardiography; imaging;
D O I
10.1161/CIRCULATIONAHA.104.513887
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - We hypothesized that autoregulatory changes in arteriolar blood volume (aBV) that develop distal to a stenosis can be measured with myocardial contrast echocardiography, allowing coronary stenosis detection at rest without recourse to stress. Methods and Results - Patients with varying degrees of coronary artery stenosis on quantitative angiography underwent high-mechanical-index myocardial contrast echocardiography at 15 Hz to allow measurement of phasic changes in aBV in large intramyocardial vessels using either Definity (group 1; n = 22) or Imagent ( group 2; n = 22). Progressive increases in the background-subtracted systolic/diastolic aBV signal ratio were noted between each level ( none, mild [< 50%], moderate [50% to 75%], and severe [> 75%]) of stenosis severity for both group 1 (0.09 +/- 0.13, 0.13 +/- 0.08, 0.58 +/- 0.22, and 0.77 +/- 0.40; P < 0.001) and group 2 (0.10 +/- 0.05, 0.27 +/- 0.18, 0.39 +/- 0.28, and 0.74 +/- 0.37; P < 0.0001) patients. A systolic/diastolic aBV signal ratio of > 0.34 provided a sensitivity and specificity of 80% and 71%, respectively, for the detection of > 75% coronary stenosis in group 1 patients, whereas a ratio of > 0.43 provided a sensitivity and specificity of 89% and 74%, respectively, for the detection of > 75% stenosis in group 2 patients. Conclusions - Both the presence and severity of a physiologically significant coronary stenosis can be detected at rest by measuring the increase in aBV on myocardial contrast echocardiography that occurs distally to the stenosis without recourse to any form of stress.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [41] Myocardial Perfusion Imaging Using Contrast Echocardiography
    H. Joachim Nesser
    Fernando Morcerf
    Claudius Teupe
    Natesa G. Pandian
    [J]. Herz, 2002, 27 : 217 - 226
  • [42] Analysis of myocardial perfusion or myocardial function for detection of regional myocardial abnormalities. An echocardiographic multicenter comparison study using myocardial contrast echocardiography and 2D echocardiography
    Hoffmann, Rainer
    Borges, Adrian C.
    Kasprzak, Jaroslaw D.
    Von Bardeleben, Stephan
    Firschke, Christian
    Greis, Christian
    Engelhardt, Marc
    Becher, Harald
    Vanoverschelde, Jean Louis
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (06): : 438 - 448
  • [43] Contrast echocardiography 1996 - A review
    Villarraga, HR
    Foley, DA
    Mulvagh, SL
    [J]. TEXAS HEART INSTITUTE JOURNAL, 1996, 23 (02): : 90 - 97
  • [44] Contrast echocardiography for the diagnosis of left ventricular thrombus in anterior myocardial infarction
    Hiroshi Wada
    Takanori Yasu
    Kenichi Sakakura
    Yuki Hayakawa
    Takeshi Ishida
    Nobuhiko Kobayashi
    Norifumi Kubo
    Junya Ako
    Shin-ichi Momomura
    [J]. Heart and Vessels, 2014, 29 : 308 - 312
  • [45] Localizing and quantifying ablation lesions in the left ventricle by myocardial contrast echocardiography
    Khoury, DS
    Rao, LY
    Ding, CX
    Sun, HB
    Youker, KA
    Panescu, D
    Nagueh, SF
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (09) : 1078 - 1087
  • [46] Contrast echocardiography for the diagnosis of left ventricular thrombus in anterior myocardial infarction
    Wada, Hiroshi
    Yasu, Takanori
    Sakakura, Kenichi
    Hayakawa, Yuki
    Ishida, Takeshi
    Kobayashi, Nobuhiko
    Kubo, Norifumi
    Ako, Junya
    Momomura, Shin-ichi
    [J]. HEART AND VESSELS, 2014, 29 (03) : 308 - 312
  • [47] Assessment of myocardial postreperfusion viability by intravenous myocardial contrast echocardiography - Analysis of the intensity and texture of opacification
    Ohmori, K
    Cotter, B
    Leistad, E
    Bhargava, V
    Wolf, PL
    Mizushige, K
    DeMaria, AN
    [J]. CIRCULATION, 2001, 103 (15) : 2021 - 2027
  • [48] HYPERVENTILATION ECHOCARDIOGRAPHY TEST FOR THE DIAGNOSIS OF MYOCARDIAL-ISCHEMIA AT REST
    MORALES, MA
    REISENHOFER, B
    ROVAI, D
    MOSCARELLI, E
    DISTANTE, A
    LABBATE, A
    [J]. EUROPEAN HEART JOURNAL, 1993, 14 (08) : 1088 - 1093
  • [49] Severe coronary artery stenoses and reduced coronary flow velocity reserve in atherosclerotic mouse model Doppler echocardiography validation study
    Saraste, Antti
    Kyto, Ville
    Laitinen, Iina
    Saraste, Markku
    Leppanen, Pia
    Yla-Herttuala, Seppo
    Saukko, Pekka
    Hartiala, Jaakko
    Knuuti, Juhani
    [J]. ATHEROSCLEROSIS, 2008, 200 (01) : 89 - 94
  • [50] ATP Stress Myocardial Contrast Echocardiography Assessment of Coronary Microvascular Disease with Spasmodic Characteristics: A Case Report
    Liu, Xuebing
    Li, Chunmei
    [J]. CARDIOLOGY DISCOVERY, 2023, 3 (03): : 221 - 225