Detection of coronary stenoses at rest with myocardial contrast echocardiography

被引:28
作者
Wei, K
Tong, KL
Belcik, T
Rafter, P
Ragosta, M
Wang, XQ
Kaul, S
机构
[1] Univ Virginia, Cardivasc Imaging Ctr, Div Cardiovasc, Dept Med, Charlottesville, VA USA
[2] Univ Virginia, Dept Hlth Evaluat Sci, Div Biostat & Epidemiol, Charlottesville, VA USA
[3] Philips Ultrasound, Andover, MA USA
关键词
contrast media; coronary disease; diagnosis; echocardiography; imaging;
D O I
10.1161/CIRCULATIONAHA.104.513887
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - We hypothesized that autoregulatory changes in arteriolar blood volume (aBV) that develop distal to a stenosis can be measured with myocardial contrast echocardiography, allowing coronary stenosis detection at rest without recourse to stress. Methods and Results - Patients with varying degrees of coronary artery stenosis on quantitative angiography underwent high-mechanical-index myocardial contrast echocardiography at 15 Hz to allow measurement of phasic changes in aBV in large intramyocardial vessels using either Definity (group 1; n = 22) or Imagent ( group 2; n = 22). Progressive increases in the background-subtracted systolic/diastolic aBV signal ratio were noted between each level ( none, mild [< 50%], moderate [50% to 75%], and severe [> 75%]) of stenosis severity for both group 1 (0.09 +/- 0.13, 0.13 +/- 0.08, 0.58 +/- 0.22, and 0.77 +/- 0.40; P < 0.001) and group 2 (0.10 +/- 0.05, 0.27 +/- 0.18, 0.39 +/- 0.28, and 0.74 +/- 0.37; P < 0.0001) patients. A systolic/diastolic aBV signal ratio of > 0.34 provided a sensitivity and specificity of 80% and 71%, respectively, for the detection of > 75% coronary stenosis in group 1 patients, whereas a ratio of > 0.43 provided a sensitivity and specificity of 89% and 74%, respectively, for the detection of > 75% stenosis in group 2 patients. Conclusions - Both the presence and severity of a physiologically significant coronary stenosis can be detected at rest by measuring the increase in aBV on myocardial contrast echocardiography that occurs distally to the stenosis without recourse to any form of stress.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [31] Myocardial perfusion assessment with contrast echocardiography
    Desco, M
    Ledesma-Carbayo, MJ
    Santos, A
    García-Fernandez, M
    Marcos-Alberca, P
    Malpica, N
    Antoranz, JC
    Garcia-Barreno, P
    MEDICAL IMAGING 2001: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2001, 4325 : 514 - 522
  • [32] Assessment of myocardial viability using myocardial contrast echocardiography
    Wei, K
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (01): : 85 - 94
  • [33] Rapid Detection of Coronary Artery Stenoses With Real-Time Perfusion Echocardiography During Regadenoson Stress
    Porter, Thomas R.
    Adolphson, Mary
    High, Robin R.
    Smith, Lynette M.
    Olson, Joan
    Erdkamp, Michelle
    Xie, Feng
    O'Leary, Edward
    Wong, Benjamin F.
    Eifert-Rain, Susan
    Hagen, Mary E.
    Abdelmoneim, Sahar S.
    Mulvagh, Sharon L.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (06) : 628 - 635
  • [34] Contrast echocardiography in coronary artery disease
    Coulter, S
    Picard, MH
    CORONARY ARTERY DISEASE, 1998, 9 (07) : 391 - 398
  • [35] Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angiography in patients with acute myocardial infarction
    Lepper, W
    Hoffmann, R
    Kamp, O
    Franke, A
    de Cock, CC
    Kühl, HP
    Sieswerda, GT
    vom Dahl, J
    Janssens, U
    Voci, P
    Visser, CA
    Hanrath, P
    CIRCULATION, 2000, 101 (20) : 2368 - 2374
  • [36] Detection of viable myocardium by transvenous myocardial contrast echocardiography using harmonic power Doppler - Canine model of acute coronary occlusion and reperfusion
    Teupe, C
    Takeuchi, M
    Yao, JF
    Avelar, E
    Pandian, N
    CHEST, 2001, 120 (02) : 567 - 572
  • [37] Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses
    Dewey, M
    Laule, M
    Krug, L
    Schnapauff, D
    Rogalla, P
    Rutsch, WF
    Hamm, B
    Lembcke, A
    INVESTIGATIVE RADIOLOGY, 2004, 39 (04) : 223 - 229
  • [38] Detection and Quantification of Myocardial Scars by Contrast-Enhanced 3D Echocardiography
    Montant, Patrick
    Chenot, Fabien
    Goffinet, Celine
    Poncelet, Alain
    Vancraeynest, David
    Pasquet, Agnes
    Gerber, Bernhard L.
    Vanoverschelde, Jean-Louis J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (04) : 415 - U93
  • [39] Myocardial perfusion imaging using contrast echocardiography
    Nesser, HJ
    Morcerf, F
    Teupe, C
    Pandian, NG
    HERZ, 2002, 27 (03) : 217 - 226
  • [40] Myocardial Perfusion Imaging Using Contrast Echocardiography
    Pathan, Faraz
    Marwick, Thomas H.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2015, 57 (06) : 632 - 643