Semi-theoretical modeling oscillatory fouling in enhanced tubes in cooling tower systems

被引:0
|
作者
Li, Wei [1 ]
机构
[1] Zhejiang Univ, Coll Mech & Energy Engn, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
来源
PROCEEDINGS OF THE ASME/JSME THERMAL ENGINEERING SUMMER HEAT TRANSFER CONFERENCE 2007, VOL 1 | 2007年
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The fluctuation of fouling data, a well-known fouling phenomenon, was recognized in applications three decades ago, but it had not yet been well understood. Of specific interest is long term, combined precipitation and particulate fouling in cooling tower systems. Fouling data collected in seven 15.54 mm I.D. copper, helically ribbed tubes at water velocity (1.07 m/s) at practical conditions shows an oscillatory behavior. In order to observe it, a water temperature difference of 3.0 degrees C, or greater, was needed for adequate accuracy based on an uncertainty analysis. Oscillatory model was used to analyze the data. The frequencies of the fluctuation are the same for the seven tested tube geometries. A series of semi-theoretical correlations of fluctuation of the long-term cooling tower water fouling data were developed. It was found that there are two ranges of amplitudes of the fluctuation based on internal parameters: linear range and non-linear range.
引用
收藏
页码:705 / 711
页数:7
相关论文
共 37 条
  • [21] A comparison between semi-theoretical and empirical modeling of cross-flow microfiltration using ANN
    Ghandehari, Sara
    Montazer-Rahmati, Mohammad Mehdi
    Asghari, Morteza
    DESALINATION, 2011, 277 (1-3) : 348 - 355
  • [22] Crossflow microsand filtration in cooling tower systems to control fouling in heat exchanger devices
    Ashok, Vaishali
    Absalan, Faezeh
    Silverwood, Alain
    Robert, Etienne
    Claveau-Mallet, Dominique
    Bedard, Emilie
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [23] Experimental Study of Fouling in Hybrid Cooling Tower Used in CSP Plants: Effects of the Polymer and galvanized steel tubes
    Zaza, A.
    Bennouna, E. G.
    Laadel, N. E.
    El Hammami, Y.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25
  • [24] CORROSION AND FOULING OF ADMIRALTY ALUMINUM AND STEEL TUBES IN OPEN RECIRCULATING COOLING WATER SYSTEMS
    GUTZEIT, J
    MATERIALS PROTECTION, 1965, 4 (07): : 28 - &
  • [25] Fouling characteristics of internal helical-rib roughness tubes using low-velocity cooling tower water
    Li, W
    Webb, RL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (08) : 1685 - 1691
  • [26] A simplified modeling of mechanical cooling tower for control and optimization of HVAC systems
    Jin, Guang-Yu
    Cai, Wen-Jian
    Lu, Lu
    Lee, Eng Lock
    Chiang, Andrew
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (02) : 355 - 365
  • [28] Thin-layer drying of flax fiber: II. Modeling drying process using semi-theoretical and empirical models
    Ghazanfari, A.
    Emami, S.
    Tabil, L. G.
    Panigrahi, S.
    DRYING TECHNOLOGY, 2006, 24 (12) : 1637 - 1642
  • [29] Modeling Based on Semi-tensor Product for Radiant Floor Cooling Systems
    Qin, Fenghua
    Wang, Chongjie
    Feng, Liye
    Lv, Hongli
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3782 - 3788
  • [30] Comprehensive numerical modeling of intermittent flow cooling with enhanced photovoltaic efficiency in PVT/NPCM systems
    Chen, Hui
    Zhang, Jianfeng
    Shen, Ming
    Fang, Hui
    Ma, Yiren
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 58