Time and Number of Displays Impact Critical Signal Detection in Fetal Heart Rate Tracings

被引:2
作者
Anderson, Brittany L. [1 ]
Scerbo, Mark W. [1 ]
Belfore, Lee A., II [2 ]
Abuhamad, Alfred Z. [3 ]
机构
[1] Old Dominion Univ, Dept Psychol, Norfolk, VA 23529 USA
[2] Eastern Virginia Med Sch, Dept Elect & Comp Engn, Norfolk, VA 23501 USA
[3] Eastern Virginia Med Sch, Dept Obstet & Gynecol, Norfolk, VA 23501 USA
关键词
Fetal heart rate; multiple displays; signal detection; stress; workload; SUSTAINED ATTENTION; VIGILANCE; PERFORMANCE; STRESS; WORKLOAD; TASK;
D O I
10.1055/s-0030-1268718
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Interest in centralized monitoring in labor and delivery units is growing because it affords the opportunity to monitor multiple patients simultaneously. However, a long history of research on sustained attention reveals these types of monitoring tasks can be problematic. The goal of the present experiment was to examine the ability of individuals to detect critical signals in fetal heart rate (FHR) tracings in one or more displays over an extended period of time. Seventy-two participants monitored one, two, or four computer-simulated FHR tracings on a computer display for the appearance of late decelerations over a 48-minute vigil. Measures of subjective stress and workload were also obtained before and after the vigil. The results showed that detection accuracy decreased over time and also declined as the number of displays increased. The subjective reports indicated that participants found the task to be stressful and mentally demanding, effortful, and frustrating. The results suggest that centralized monitoring that allows many patients to be monitored simultaneously may impose a detrimental attentional burden on the observer. Furthermore, this seemingly benign task may impose an additional source of stress and mental workload above what is commonly found in labor and delivery units.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 23 条
  • [1] REACTION TIME AS A MEASURE OF PERCEPTUAL VIGILANCE
    BUCK, L
    [J]. PSYCHOLOGICAL BULLETIN, 1966, 65 (05) : 291 - &
  • [2] Davies D.R., 1982, PSYCHOL VIGILANCE
  • [3] Problems with intrapartum fetal heart rate monitoring interpretation and patient management
    Freeman, RK
    [J]. OBSTETRICS AND GYNECOLOGY, 2002, 100 (04) : 813 - 826
  • [4] The vigilance decrement reflects limitations in effortful attention, not mindlessness
    Grier, RA
    Warm, JS
    Dember, WN
    Matthews, G
    Galinsky, TL
    Szalma, JL
    Parasuraman, R
    [J]. HUMAN FACTORS, 2003, 45 (03) : 349 - 359
  • [5] HANCOCK PA, 1989, HUM FACTORS, V31, P519
  • [6] HART S G, 1988, P139
  • [7] Helton W.S., 2004, Proc. Hum. Factors Ergon. Soc. Annu. Meet., V48, P1238, DOI DOI 10.1177/154193120404801107
  • [8] Jerison H.J., 1963, VIGILANCE S, P199
  • [9] COMPONENTS OF COMPLEX MONITORING
    JOHNSTON, WA
    HOWELL, WC
    WILLIGES, RC
    [J]. ORGANIZATIONAL BEHAVIOR AND HUMAN PERFORMANCE, 1969, 4 (02): : 112 - 124
  • [10] THE BREAKDOWN OF VIGILANCE DURING PROLONGED VISUAL SEARCH
    Mackworth, N. H.
    [J]. QUARTERLY JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1948, 1 : 6 - 21