Cortical evoked responses following esophageal balloon distension and electrical stimulation in healthy volunteers

被引:27
作者
Hollerbach, S
Hudoba, P
Fitzpatrick, D
Hunt, R
Upton, ARM
Tougas, G
机构
[1] McMaster Univ, Dept Med, GI Div, Med Ctr,Div Gastroenterol, Hamilton, ON L8N 3Z5, Canada
[2] McMaster Univ, Dept Med, Dept Neurol, Med Ctr, Hamilton, ON L8N 3Z5, Canada
基金
英国医学研究理事会;
关键词
evoked potentials; mechanical stimulation; electrical stimulation; vagal afferents; conduction velocity;
D O I
10.1023/A:1026667123187
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Recording of evoked potential responses represents an objective and quantifiable method to study visceral afferent sensory pathways in humans. We examined the evoked responses to mechanical distension (balloon) and electrical stimulation of the proximal and distal esophagus. A standard manometric catheter with a latex balloon and an additional electrode attached to its body was placed in the lower esophagus in 15 healthy young volunteers. Repeated nonpainful balloon distension stimuli above the individual sensation threshold (0.17 Hz, 12-20 mi) or short electrical impulses (0.2 Hz, 12-16 mA) were delivered in an alternate fashion at 23 and 33 cm from the nares. Evoked potential responses (EP) were recorded through 22 scalp surface electrodes using the standard 10/20 International EEG system of electrode placement. Balloon distension produced a reproducible triphasic response at both sites. Peak latencies of three negative EP peaks were 92 +/- 17, 229 +/- 40, and 339 +/- 36 msec with proximal stimulation versus 154 +/- 24, 275 +/- 24, and 384 +/- 30 msec obtained with distal stimulation (P < 0.001). Electrical stimulation produced a triphasic response with significantly shorter peak latencies at both sites when compared to mechanical stimulation (P < 0.001). Peak latencies were 74 +/- 12, 137 +/- 11, and 245 +/- 27 msec proximal versus 83 +/- 12, 148 +/- 32, and 247 +/- 51 msec with distal stimulation (P < 0.01). The calculated conduction velocities for both modes of stimulation (balloon: 1.73 +/- 0.9 m/sec vs electrical: 10.1 +/- 3.4 m/sec) are compatible with conduction through C fibers and A delta fibers, respectively. Both modes of stimulation produce characteristic brain responses that are conveyed through different types of afferent fibers. The respective contributions of both types of fibers to esophageal function and symptomatology can be specifically addressed using this approach in both normal and pathologic conditions.
引用
收藏
页码:2558 / 2566
页数:9
相关论文
共 50 条
  • [31] Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation
    M. V. Kamath
    G. Tougas
    S. Hollerbach
    R. Premji
    D. Fitzpatrick
    G. Shine
    A. R. M. Upton
    [J]. Medical and Biological Engineering and Computing, 1997, 35 : 343 - 347
  • [32] Combined neuromuscular electrical stimulation and transcutaneous spinal direct current stimulation increases motor cortical plasticity in healthy humans
    Koseki, Tadaki
    Kudo, Daisuke
    Yoshida, Kaito
    Nito, Mitsuhiro
    Takano, Keita
    Jin, Masafumi
    Tanabe, Shigeo
    Sato, Toshiaki
    Katoh, Hiroshi
    Yamaguchi, Tomofumi
    [J]. FRONTIERS IN NEUROSCIENCE, 2023, 16
  • [33] Electrical stimulation with a penetrating optic nerve electrode array elicits visuotopic cortical responses in cats
    Lu, Yiliang
    Yan, Yan
    Chai, Xinyu
    Ren, Qiushi
    Chen, Yao
    Li, Liming
    [J]. JOURNAL OF NEURAL ENGINEERING, 2013, 10 (03)
  • [34] Electrically evoked auditory cortical responses elicited from individually fitted stimulation parameters in cochlear implant users
    Callejon-Leblic, Maria A.
    Barrios-Romero, Maria M.
    Kontides, Alejandra
    Sanchez-Gomez, Serafin
    Beynon, Andy J.
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2023, 62 (07) : 650 - 658
  • [35] Noxiousness of Hypertension-related Norepinephrine and Upregulation of Norepinephrine Induced by High Intensity Electrical Stimulation in Healthy Volunteers
    Kim, Ju-Hyun
    Lee, Jeong-Uk
    Kim, Il-Hyun
    Kim, Mee-Young
    Kim, Bokyung
    Kim, Junghwan
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2012, 24 (09) : 795 - 800
  • [36] Development of a silicon retinal implant: cortical evoked potentials following focal stimulation of the rabbit retina with light and electricity
    Nadig, MN
    [J]. CLINICAL NEUROPHYSIOLOGY, 1999, 110 (09) : 1545 - 1553
  • [37] Effect of Obesity on Masticatory Muscle Activity and Rhythmic Jaw Movements Evoked by Electrical Stimulation of Different Cortical Masticatory Areas
    Li, Ruixin
    Kato, Chiho
    Fujita, Akiyo
    Abe, Yasunori
    Ogawa, Takuya
    Ishidori, Hideyuki
    Misawa, Eri
    Okihara, Hidemasa
    Kokai, Satoshi
    Ono, Takashi
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (11)
  • [38] Comparison of motor effects following subcortical electrical stimulation through electrodes in the globus pallidus internus and cortical transcranial magnetic stimulation
    Kühn, AA
    Brandt, SA
    Kupsch, A
    Trottenberg, T
    Brocke, J
    Irlbacher, K
    Schneider, GH
    Meyer, BU
    [J]. EXPERIMENTAL BRAIN RESEARCH, 2004, 155 (01) : 48 - 55
  • [39] Comparison of motor effects following subcortical electrical stimulation through electrodes in the globus pallidus internus and cortical transcranial magnetic stimulation
    Andrea A. Kühn
    Stephan A. Brandt
    Andreas Kupsch
    Thomas Trottenberg
    Jan Brocke
    Kerstin Irlbacher
    Gerd H. Schneider
    Bernd-Ulrich Meyer
    [J]. Experimental Brain Research, 2004, 155 : 48 - 55
  • [40] Properties of auditory brainstem responses evoked by intra-operative electrical stimulation of the cochlear nucleus in human subjects
    Waring, MD
    [J]. EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1996, 100 (06): : 538 - 548