Magnetized graphene layers synthesized on the carbon nanofibers as novel adsorbent for the extraction of polycyclic aromatic hydrocarbons from environmental water samples

被引:55
|
作者
Rezvani-Eivari, Mostafa [1 ]
Amiri, Amirhassan [1 ]
Baghayeri, Mehdi [1 ]
Ghaemi, Ferial [2 ]
机构
[1] Hakim Sabzevari Univ, Fac Sci, Dept Chem, Sabzevar, Iran
[2] Univ Putra Malaysia, Inst Trop Forestry & Forest Prod, Serdang 43400, Selangor, Malaysia
关键词
Gas chromatography-flame ionization detector; Polycyclic aromatic hydrocarbons; Magnetic solid-phase extraction; Graphene; Carbon nanofiber; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; BAR SORPTIVE EXTRACTION; MASS-SPECTROMETRY; FLUORESCENCE DETECTION; RAMAN-SPECTROSCOPY; STIR BARS; MICROEXTRACTION; NANOTUBES; NANOPARTICLES;
D O I
10.1016/j.chroma.2016.08.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of magnetized graphene (G) layers synthesized on the carbon nanofibers (CNFs) (m-G/CNF) was investigated as novel adsorbent for the magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) in water samples followed by gas chromatography-flame ionization detector (GC-FID). Six important parameters, affecting the extraction efficienc'y of PAHs, including: amount of adsorbent, adsorption and desorption times, type and volume of the eluent solvent and salt content of the sample were evaluated. The optimum extraction conditions were obtained as: 5 min for extraction time, 20 mg for sorbent amount, dichloromethane as desorption solvent, 1 mL for desorption solvent volume, 5 min for desorption time and 15% (w/v) for NaCl concentration. Good performance data were obtained at the optimized conditions. The calibration curves were linear over the concentration ranges from 0.012 to 100 ng mL(-1) with correlation coefficients (r) between 0.9950 and 0.9967 for all the analytes. The limits of detection (LODs, S/N = 3) of the proposed method for the studied PAHs were 0.004-0.03 ngmL(-1). The relative standard deviations (RSDs) for five replicates at two concentration levels (0.1 and 50 ng mL(-1)) of PAHs were ranged from 3.4 to 5.7%. Appropriate relative recovery values, in the range of 95.5-99.9%, were also obtained for the real water sample analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [41] Optimization of ultrasonic extraction of polycyclic aromatic hydrocarbons from sewage sludge samples
    Oleszczuk, P
    Baran, S
    CHEMIA ANALITYCZNA, 2003, 48 (02): : 211 - 221
  • [42] Biocompatible phosphatidylcholine bilayer coated on magnetic nanoparticles and their application in the extraction of several polycyclic aromatic hydrocarbons from environmental water and milk samples
    Zhang, Shengxiao
    Niu, Hongyun
    Zhang, Yuanyuan
    Liu, Junshen
    Shi, Yali
    Zhang, Xiaole
    Cai, Yaqi
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1238 : 38 - 45
  • [43] Spent tea leaves as an adsorbent for micro-solid-phase extraction of polycyclic aromatic hydrocarbons (PAHs) from water and food samples prior to GC-FID analysis
    Nazir, Nazzatul Atirah Mohd
    Raoov, Muggundha
    Mohamad, Sharifah
    MICROCHEMICAL JOURNAL, 2020, 159
  • [44] Determination of Polycyclic Aromatic Hydrocarbons in Water Samples Using Solid-Phase Extraction Procedure and High-Performance Liquid Chromatography With Fluorescence Detection
    Ghanmi, Safouane
    Ben Hassine, Sihem
    Bouabdallah, Sondes
    Driss, Mohamed Ridha
    Touil, Soufiane
    SEPARATION SCIENCE PLUS, 2025, 8 (01):
  • [45] Application of sulfur-coated magnetic carbon nanotubes for extraction of some polycyclic aromatic hydrocarbons from water resources
    Sun, Wen
    Hong, Yaoliang
    Li, Tian
    Chu, Huaqiang
    Liu, Junxia
    Feng, Li
    CHEMOSPHERE, 2022, 309
  • [46] Poly(pyrrole-co-aniline)@graphene oxide/Fe3O4 sorbent for the extraction and preconcentration of polycyclic aromatic hydrocarbons from water samples
    Amiri, Amirhassan
    Baghayeri, Mehdi
    Hamidi, Eliye
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (20) : 16744 - 16751
  • [47] Two novel zeolitic imidazolate frameworks (ZIFs) as sorbents for solid-phase extraction (SPE) of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples
    Hu, Huiping
    Liu, Shengquan
    Chen, Chunyan
    Wang, Jianping
    Zou, Ying
    Lin, Lihua
    Yao, Shouzhuo
    ANALYST, 2014, 139 (22) : 5818 - 5826
  • [48] Graphene oxide framework: An adsorbent for solid phase extraction of phenylurea herbicides from water and celery samples
    Li, Menghua
    Wang, Juntao
    Jiao, Caina
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1469 : 17 - 24
  • [49] A Novel Magnetic β-Cyclodextrin-Modified Graphene Oxide and Chitosan Composite as an Adsorbent for Trace Extraction of Four Bisphenol Pollutants from Environmental Water Samples and Food Samples
    Gong, Yichao
    Liu, Pengyan
    MOLECULES, 2024, 29 (04):
  • [50] Magnetic Polyeugenol Nanoparticles as a New Sorbent for Solid-Phase Extraction of Polycyclic Aromatic Hydrocarbons in Environmental Water and Food Samples
    Rezaei, Mahdie
    Mehdinia, Ali
    Shemirani, Farzaneh
    CHEMISTRYSELECT, 2023, 8 (11):