Magnetized graphene layers synthesized on the carbon nanofibers as novel adsorbent for the extraction of polycyclic aromatic hydrocarbons from environmental water samples

被引:55
作者
Rezvani-Eivari, Mostafa [1 ]
Amiri, Amirhassan [1 ]
Baghayeri, Mehdi [1 ]
Ghaemi, Ferial [2 ]
机构
[1] Hakim Sabzevari Univ, Fac Sci, Dept Chem, Sabzevar, Iran
[2] Univ Putra Malaysia, Inst Trop Forestry & Forest Prod, Serdang 43400, Selangor, Malaysia
关键词
Gas chromatography-flame ionization detector; Polycyclic aromatic hydrocarbons; Magnetic solid-phase extraction; Graphene; Carbon nanofiber; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; BAR SORPTIVE EXTRACTION; MASS-SPECTROMETRY; FLUORESCENCE DETECTION; RAMAN-SPECTROSCOPY; STIR BARS; MICROEXTRACTION; NANOTUBES; NANOPARTICLES;
D O I
10.1016/j.chroma.2016.08.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of magnetized graphene (G) layers synthesized on the carbon nanofibers (CNFs) (m-G/CNF) was investigated as novel adsorbent for the magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) in water samples followed by gas chromatography-flame ionization detector (GC-FID). Six important parameters, affecting the extraction efficienc'y of PAHs, including: amount of adsorbent, adsorption and desorption times, type and volume of the eluent solvent and salt content of the sample were evaluated. The optimum extraction conditions were obtained as: 5 min for extraction time, 20 mg for sorbent amount, dichloromethane as desorption solvent, 1 mL for desorption solvent volume, 5 min for desorption time and 15% (w/v) for NaCl concentration. Good performance data were obtained at the optimized conditions. The calibration curves were linear over the concentration ranges from 0.012 to 100 ng mL(-1) with correlation coefficients (r) between 0.9950 and 0.9967 for all the analytes. The limits of detection (LODs, S/N = 3) of the proposed method for the studied PAHs were 0.004-0.03 ngmL(-1). The relative standard deviations (RSDs) for five replicates at two concentration levels (0.1 and 50 ng mL(-1)) of PAHs were ranged from 3.4 to 5.7%. Appropriate relative recovery values, in the range of 95.5-99.9%, were also obtained for the real water sample analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 44 条
[1]   Magnetic nanoparticles modified with polyfuran for the extraction of polycyclic aromatic hydrocarbons prior to their determination by gas chromatography [J].
Amiri, Amirhassan ;
Baghayeri, Mehdi ;
Kashmari, Milad .
MICROCHIMICA ACTA, 2016, 183 (01) :149-156
[2]   Magnetic solid-phase extraction using poly(para-phenylenediamine) modified with magnetic nanoparticles as adsorbent for analysis of monocyclic aromatic amines in water and urine samples [J].
Amiri, Amirhassan ;
Baghayeri, Mehdi ;
Noni, Somayeh .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1415 :20-26
[3]   Functionalization of carbon nanotubes by electrochemical reduction of aryl diazonium salts: A bucky paper electrode [J].
Bahr, JL ;
Yang, JP ;
Kosynkin, DV ;
Bronikowski, MJ ;
Smalley, RE ;
Tour, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (27) :6536-6542
[4]   Comprehensive analysis of polycyclic aromatic hydrocarbons in wastewater using stir bar sorptive extraction and gas chromatography coupled to tandem mass spectrometry [J].
Barco-Bonilla, Nieves ;
Romero-Gonzalez, Roberto ;
Plaza-Bolanos, Patricia ;
Luis Fernandez-Moreno, Jose ;
Garrido Frenich, Antonia ;
Martinez Vidal, Jose Luis .
ANALYTICA CHIMICA ACTA, 2011, 693 (1-2) :62-71
[5]   Simultaneous determination of polycyclic aromatic hydrocarbons and benzene, toluene, ethylbenzene and xylene in water samples using a new sampling strategy combining different extraction modes and temperatures in a single extraction solid-phase microextraction-gas chromatography-mass spectrometry procedure [J].
Bianchin, Joyce Nunes ;
Nardini, Giuliana ;
Merib, Josias ;
Dias, Adriana Neves ;
Martendal, Edmar ;
Carasek, Eduardo .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1233 :22-29
[6]   Multivariate optimization of a liquid-liquid extraction of the EPA-PAHs from natural contaminated waters prior to determination by liquid chromatography with fluorescence detection [J].
Brum, Daniel Mares ;
Cassella, Ricardo J. ;
Pereira Netto, Annibal D. .
TALANTA, 2008, 74 (05) :1392-1399
[7]   Ultra high performance liquid chromatography-atmospheric pressure photoionization-mass spectrometry for high-sensitivity analysis of US Environmental Protection Agency sixteen priority pollutant polynuclear aromatic hydrocarbons in oysters [J].
Cai, Sheng-Suan ;
Stevens, Joan ;
Syage, Jack A. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1227 :138-144
[8]   Quantification of 13 priority polycyclic aromatic hydrocarbons in human urine by headspace solid-phase microextraction gas chromatography-isotope dilution mass spectrometry [J].
Campo, Laura ;
Mercadante, Rosa ;
Rossella, Federica ;
Fustinoni, Silvia .
ANALYTICA CHIMICA ACTA, 2009, 631 (02) :196-205
[9]   Nonionic surfactant mixtures:: a new cloud-point extraction approach for the determination of PAHs in seawater using HPLC with fluorimetric detection [J].
Delgado, B ;
Pino, V ;
Ayala, JH ;
González, V ;
Afonso, AM .
ANALYTICA CHIMICA ACTA, 2004, 518 (1-2) :165-172
[10]   Characterizing Graphene, Graphite, and Carbon Nanotubes by Raman Spectroscopy [J].
Dresselhaus, M. S. ;
Jorio, A. ;
Saito, R. .
ANNUAL REVIEW OF CONDENSED MATTER PHYSICS, VOL 1, 2010, 1 :89-108