Seismic Risk Mitigation of Historical Masonry Towers by Means of Prestressing Devices

被引:5
作者
Quiroz, Adolfo Preciado [1 ]
Sperbeck, Silvio T. [1 ]
Budelmann, Harald [1 ]
Bartoli, Gianni [2 ]
Bazrafshan, Elham [1 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Braunschweig, Germany
[2] Univ Florence, Florence, Italy
来源
7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2 | 2010年 / 133-134卷
关键词
hHistorical masonry tower; seismic risk management (risk assessment and mitigation); linear and nonlinear analyses; prestressing devices as structural rehabilitation;
D O I
10.4028/www.scientific.net/AMR.133-134.843
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work presents the investigation of the efficiency of different prestressing devices as a rehabilitation measure for the seismic risk mitigation of historical masonry towers. As a first phase, the seismic vulnerability of theoretical masonry towers was assessed by means of numerical models validated with information from the literature, observed damage and behavior of these structures due to passed earthquakes (crack pattern and failure mechanisms), and mainly taking into account the engineering experience. Afterwards, the validated models were rehabilitated with different prestressing devices; analyzing the results and concluding which device or the combination of them improved in a better way the seismic performance of the masonry towers. Finally, the methodology will be applied in two historical masonry towers located in seismic areas; the medieval tower "Torre Grossa" of San Gimignano, Italy, and one of the bell towers of the Cathedral of Colima, Mexico.
引用
收藏
页码:843 / +
页数:2
相关论文
共 11 条
[1]  
[Anonymous], [No title captured]
[2]  
Bachmann H., 1997, Vibration Problems in Structures, practical guidelines
[3]   Modal Parameter Identification of Hagia Sophia Bell-Tower via Ambient Vibration Test [J].
Bayraktar, Alemdar ;
Turker, Temel ;
Sevim, Baris ;
Altunisik, Ahmet Can ;
Yildirim, Faruk .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2009, 28 (01) :37-47
[4]  
CALDERINI C, 2004, CONSTITUTIVE MODEL M
[5]  
Casolo S., 1998, J. Earthq. Eng, V2, P487, DOI DOI 10.1080/13632469809350332
[6]  
Gambarotta L, 1997, EARTHQUAKE ENG STRUC, V26, P441, DOI 10.1002/(SICI)1096-9845(199704)26:4<441::AID-EQE651>3.0.CO
[7]  
2-0
[8]  
Grunthal G., 1998, CAHIERS CTR EUROP EN, V15
[9]  
Ivorra S, 2008, STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTION: PRESERVING SAFETY AND SIGNIFICANCE, VOLS 1 AND 2, P349
[10]  
LANG K, 2002, THESIS ETH ZURICH