摘要
We propose a real-time cardiac imaging method with parallel MRI that allows for free breathing during imaging and does not require cardiac or respiratory gating. The method is based on the recently proposed PARADISE (Patient-Adaptive Reconstruction and Acquisition Dynamic Imaging with Sensitivity Encoding) scheme. The new acquisition method adapts the PARADISE k-t space sampling pattern according to an affine model of the respiratory motion. The reconstruction scheme involves multi-channel time-sequential imaging with time-varying channels. All model parameters are adapted to the imaged patient as part of the experiment and drive both data acquisition and cine reconstruction. Simulated cardiac MRI experiments using the realistic NCAT phantom show high quality cine reconstructions and robustness to modeling inaccuracies.
引用
收藏
页码:1076 / 1079
页数:4
相关论文
共 9 条
  • [1] Aggarwal N, 2002, 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, P737, DOI 10.1109/ISBI.2002.1029363
  • [2] AGGARWAL N, 2004, P 2 IEEE INT S BIOM
  • [3] Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model
    Manke, D
    Nehrke, K
    Börnert, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 122 - 131
  • [4] A study of the motion and deformation of the heart due to respiration
    McLeish, K
    Hill, DLG
    Atkinson, D
    Blackall, JM
    Razavi, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1142 - 1150
  • [5] Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
  • [6] 2-S
  • [7] A realistic spline-based dynamic heart phantom
    Segars, WP
    Lalush, DS
    Tsui, BMW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 503 - 506
  • [8] Sharif B, 2006, I S BIOMED IMAGING, P45, DOI 10.1109/ISBI.2006.1624848
  • [9] Lattice-theoretic analysis of time-sequential sampling of spatiotemporal signals .1.
    Willis, NP
    Bresler, Y
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 1997, 43 (01) : 190 - 207