Requirements-centric closed-loop validation of implantable cardiac devices

被引:0
|
作者
Ai, Weiwei [1 ]
Patel, Nitish [1 ]
Roop, Partha [1 ]
机构
[1] Univ Auckland, Dept Elect & Comp Engn, Auckland 1, New Zealand
来源
PROCEEDINGS OF THE 2016 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE) | 2016年
关键词
VERIFICATION; MODEL;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Implantable medical devices are recommended by physicians to sustain life while improving the overall quality of life of the patients. In spite of the rigorous testing, there have been numerous failures and associated recalls which suggest that completeness of the testing is elusive. We propose a new validation framework based on formal methods for real-time closed-loop validation of medical devices. The proposed approach includes a synchronous observer acting both as an automated oracle and also as a requirements coverage monitor. The observer combines an on-line testing adequacy evaluation module together with a heuristic learning module. This methodology was applied to validate a pacemaker over a virtual heart model. A subset of the requirements was used to test its efficacy. The results show that the proposed methodology can, in real-time, evaluate the test adequacy and hence guide the on-line test case generation to maximize the requirements coverage.
引用
收藏
页码:846 / 849
页数:4
相关论文
共 50 条
  • [21] Closed-Loop Modeling of Cardiac Pacemaker and Heart
    Mery, Dominique
    Singh, Neeraj Kumar
    FOUNDATIONS OF HEALTH INFORMATION ENGINEERING AND SYSTEMS (FHIES 2012), 2013, 7789 : 151 - 166
  • [22] Wirelessly Powered, Batteryless Closed-loop Biopotential Recording IC for Implantable Leadless Cardiac Monitoring Applications
    Jang, Jaeeun
    Habibagahi, Iman
    Rahmani, Hamed
    Babakhani, Aydin
    2021 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (IEEE BIOCAS 2021), 2021,
  • [23] Wireless, fully implantable cardiac stimulation and recording with on-device computation for closed-loop pacing and defibrillation
    Ausra, Jokubas
    Madrid, Micah
    Yin, Rose T.
    Hanna, Jessica
    Arnott, Suzanne
    Brennan, Jaclyn A.
    Peralta, Roberto
    Clausen, David
    Bakall, Jakob A.
    Efimov, Igor R.
    Gutruf, Philipp
    SCIENCE ADVANCES, 2022, 8 (43)
  • [24] A Programmable Implantable Microstimulator SoC With Wireless Telemetry: Application in Closed-Loop Endocardial Stimulation for Cardiac Pacemaker
    Lee, Shuenn-Yuh
    Su, Mario YuCheng
    Liang, Ming-Chun
    Chen, You-Yin
    Hsieh, Cheng-Han
    Yang, Chung-Min
    Lai, Hsin-Yi
    Lin, Jou-Wei
    Fang, Qiang
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2011, 5 (06) : 511 - 522
  • [25] Closed-Loop Control of Facts Devices in Power System
    Jebaseelan, S. D. Sundarsingh
    Ravi, C. N.
    Nagarajan, G.
    Marlin, S.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SOFT COMPUTING SYSTEMS, ICSCS 2015, VOL 1, 2016, 397 : 361 - 369
  • [26] Conformable electrochemical devices for closed-loop wound management
    Li, Jie
    Li, Zhangping
    Xiao, Jian
    Nie, Chenyao
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [27] Towards miniaturized closed-loop optogenetic stimulation devices
    Edward, Epsy S.
    Kouzani, Abbas Z.
    Tye, Susannah J.
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (02)
  • [28] Advances in closed-loop deep brain stimulation devices
    Parastarfeizabadi, Mahboubeh
    Kouzani, Abbas Z.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14 : 79
  • [29] Generalized modal analysis for closed-loop piezoelectric devices
    Giraud-Audine, Christophe
    Giraud, Frederic
    Amberg, Michel
    Lemaire-Semail, Betty
    SMART MATERIALS AND STRUCTURES, 2015, 24 (08)
  • [30] Advances in closed-loop deep brain stimulation devices
    Mahboubeh Parastarfeizabadi
    Abbas Z. Kouzani
    Journal of NeuroEngineering and Rehabilitation, 14