Voltammetric Study for the Determination of Diclofenac in Aqueous Solutions Using Electro-Activated Carbon Electrodes

被引:8
|
作者
Berto, Silvia [1 ]
Cagno, Enrico [1 ]
Prenesti, Enrico [1 ]
Aragona, Giulia [1 ]
Bertinetti, Stefano [1 ]
Giacomino, Agnese [2 ]
Inaudi, Paolo [2 ]
Malandrino, Mery [1 ]
Terranova, Emanuele [1 ]
Abollino, Ornella [2 ]
机构
[1] Univ Turin, Dept Chem, Via P Giuria 7, I-10125 Turin, Italy
[2] Univ Turin, Dept Drug Sci & Technol, Via P Giuria 9, I-10125 Turin, Italy
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 16期
关键词
diclofenac; glassy carbon electrode; screen printed electrodes; voltammetry; electrochemical activation; natural surface waters; ELECTROCHEMICAL DETERMINATION; GRAPHITE ELECTRODE; ACETAMINOPHEN; SODIUM; SENSOR;
D O I
10.3390/app12167983
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application The knowledge acquired in this work on the diclofenac electrochemical behavior will be essential to develop a voltammetric sensor for the drug detection in water samples. Diclofenac (DCF) is a nonsteroidal anti-inflammatory drug to treat pain and inflammatory diseases. The high consumption of the drug leads to a significant change in the ecosystem. With the aim of optimizing a fast screening analysis for DCF detection on many samples with a sensitive and cheap procedure, we considered electrochemical methods using carbon-based electrodes as sensors. The electrochemical behavior of the DCF was studied on glassy carbon electrodes (GCE) and on screen-printed carbon electrodes (SPCEs) from two different suppliers after an anodic activation. The surface of the SPCEs was analyzed by scanning electron microscope (SEM) and Energy Dispersive Spectrometry (EDS). On all the activated electrodes, the voltammetric procedure (Differential Pulse Voltammetry) for the determination of DCF was optimized by the Experimental Design method, and the linearity range of the response, as well as the calibration and limit parameters (limits of detection-LoD; limit of quantification-LoQ), were defined. Analyses on SPCEs were performed both by immersing the electrode in the solution and by deposing a drop of solution on the electrode. DCF signals are stabilized by the polishing process and enhanced by the anodic activation and acid pH. The electrochemical response of DCF is not reversible, and its by-products tend to be adsorbed on the surfaces, particularly on GCE. The lowest limit parameters were obtained using the GCE (LoD = 1.6 mu g L-1) and the SPCE, having the smallest surface, immersed in solution (LoD = 7 mu g L-1).
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Square wave voltammetric determination of diclofenac in liquid phase using a novel ionic liquid multiwall carbon nanotubes paste electrode
    Goodarzian, Maryam
    Khalilzade, Mohammad A.
    Karimi, Fatemeh
    Gupta, Vinod Kumar
    Keyvanfard, Mohsen
    Bagheri, Hassan
    Fouladgar, Masoud
    JOURNAL OF MOLECULAR LIQUIDS, 2014, 197 : 114 - 119
  • [32] Simultaneous Electrochemical Determination of Paracetamol, Dopamine and Diclofenac at Diacerein Modified Carbon paste Electrode: A Voltammetric Study
    Sathisha, Arehalli
    Swamy, Bahaddurghatta E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (11): : 1437 - 1448
  • [33] Enhancing or not: What dominates the response signal of phenolic compounds on electro-activated glassy carbon electrode?
    Wei, Qingshuang
    Zong, Xinrong
    Lv, Yitao
    Wang, Chaoqi
    Wang, Jiacheng
    Zhang, Min
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 967
  • [34] Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes
    Bavol, Dmytro
    Zima, Jiri
    Barek, Jiri
    Dejmkova, Hana
    ELECTROANALYSIS, 2016, 28 (05) : 1029 - 1034
  • [35] Carbon based electrodes for the voltammetric determination of capsaicin in spicy samples
    Jimenez, Ivet
    Perez-Rafols, Clara
    Serrano, Nuria
    del Valle, Manel
    Diaz-Cuzc, Jose Manuel
    MICROCHEMICAL JOURNAL, 2023, 191
  • [36] Adsorption of Diclofenac from aqueous solution using activated carbon prepared from olive stones
    Larous, Soumaya
    Meniai, Abdeslam-Hassen
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (24) : 10380 - 10390
  • [37] Voltammetric Determination of Dopamine in the Presence of Caffeine Using a Modified Glassy Carbon Electrode
    Ebrahimi, Maryam
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2023, 59 (05) : 634 - 643
  • [38] Voltammetric study of the behaviour of N-acetyl-p-aminophenol in aqueous solutions at a platinum electrode
    Wudarska, Edyta
    Chrzescijanska, Ewa
    Kusmierek, Elzbieta
    Rynkowski, Jacek
    COMPTES RENDUS CHIMIE, 2015, 18 (09) : 993 - 1000
  • [39] Voltammetric Determination of Flavonoids in Medicinal Plant Materials Using Electrodes Modified by Cerium Dioxide Nanoparticles and Surfactants
    Ziyatdinova, G. K.
    Zakharova, S. P.
    Ziganshina, E. R.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 74 (08) : 816 - 824
  • [40] Using Fe-Cu/HGF composite cathodes for the degradation of Diuron by electro-activated peroxydisulfate
    Zhu, Lijing
    Li, Mengya
    Qi, Haiqiang
    Sun, Zhirong
    CHEMOSPHERE, 2022, 291