Voltammetric Study for the Determination of Diclofenac in Aqueous Solutions Using Electro-Activated Carbon Electrodes

被引:8
|
作者
Berto, Silvia [1 ]
Cagno, Enrico [1 ]
Prenesti, Enrico [1 ]
Aragona, Giulia [1 ]
Bertinetti, Stefano [1 ]
Giacomino, Agnese [2 ]
Inaudi, Paolo [2 ]
Malandrino, Mery [1 ]
Terranova, Emanuele [1 ]
Abollino, Ornella [2 ]
机构
[1] Univ Turin, Dept Chem, Via P Giuria 7, I-10125 Turin, Italy
[2] Univ Turin, Dept Drug Sci & Technol, Via P Giuria 9, I-10125 Turin, Italy
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 16期
关键词
diclofenac; glassy carbon electrode; screen printed electrodes; voltammetry; electrochemical activation; natural surface waters; ELECTROCHEMICAL DETERMINATION; GRAPHITE ELECTRODE; ACETAMINOPHEN; SODIUM; SENSOR;
D O I
10.3390/app12167983
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application The knowledge acquired in this work on the diclofenac electrochemical behavior will be essential to develop a voltammetric sensor for the drug detection in water samples. Diclofenac (DCF) is a nonsteroidal anti-inflammatory drug to treat pain and inflammatory diseases. The high consumption of the drug leads to a significant change in the ecosystem. With the aim of optimizing a fast screening analysis for DCF detection on many samples with a sensitive and cheap procedure, we considered electrochemical methods using carbon-based electrodes as sensors. The electrochemical behavior of the DCF was studied on glassy carbon electrodes (GCE) and on screen-printed carbon electrodes (SPCEs) from two different suppliers after an anodic activation. The surface of the SPCEs was analyzed by scanning electron microscope (SEM) and Energy Dispersive Spectrometry (EDS). On all the activated electrodes, the voltammetric procedure (Differential Pulse Voltammetry) for the determination of DCF was optimized by the Experimental Design method, and the linearity range of the response, as well as the calibration and limit parameters (limits of detection-LoD; limit of quantification-LoQ), were defined. Analyses on SPCEs were performed both by immersing the electrode in the solution and by deposing a drop of solution on the electrode. DCF signals are stabilized by the polishing process and enhanced by the anodic activation and acid pH. The electrochemical response of DCF is not reversible, and its by-products tend to be adsorbed on the surfaces, particularly on GCE. The lowest limit parameters were obtained using the GCE (LoD = 1.6 mu g L-1) and the SPCE, having the smallest surface, immersed in solution (LoD = 7 mu g L-1).
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Amperometric Determination of Dopamine Using Activated Screen-Printed Carbon Electrodes
    Pan, Deng
    Rong, Shengzhong
    Zhang, Guangteng
    Zhang, Yannan
    Zhou, Qiang
    Liu, Fenghai
    Li, Miaojing
    Chang, Dong
    Pan, Hongzhi
    ELECTROCHEMISTRY, 2015, 83 (09) : 725 - 729
  • [22] Metal nanoparticles/carbon nanotube modified electrodes for voltammetric determination of boron
    Liv, Lokman
    Dursun, Zekerya
    Nakiboglu, Nuri
    TURKISH JOURNAL OF CHEMISTRY, 2018, 42 (06) : 1611 - 1622
  • [23] Voltammetric determination of sulfamethoxazole using commercial screen-printed carbon electrodes
    Alberto, Elena
    Bastos-Arrieta, Julio
    Perez-Rafols, Clara
    Serrano, Nuria
    Diaz-Cruz, M. Silvia
    Diaz-Cruz, Jose Manuel
    MICROCHEMICAL JOURNAL, 2023, 193
  • [24] Amino-attapulgite/mesoporous silica composite films generated by electro-assisted self-assembly for the voltammetric determination of diclofenac
    Jiokeng, Sherman L. Z.
    Tonle, Ignas K.
    Walcarius, Alain
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 287 : 296 - 305
  • [25] Voltammetric Determination of Cymoxanil on Carbon-based Electrodes
    Bavol, Dmytro
    Zima, Jiri
    Barek, Jiri
    Dejmkova, Hana
    XXXIV. MODERNI ELEKTROCHEMICKE METODY, 2014, : 14 - 18
  • [26] Removal of carbamazepine in water by electro-activated carbon fiber-peroxydisulfate: Comparison, optimization, recycle, and mechanism study
    Liu, Zhen
    Zhao, Chun
    Wang, Pu
    Zheng, Huaili
    Sun, Yongjun
    Dionysiou, Dionysios D.
    CHEMICAL ENGINEERING JOURNAL, 2018, 343 : 28 - 36
  • [27] Voltammetric determination of promethazine by platinum and glassy carbon electrodes
    Uslu, B
    Biryol, I
    Ozkan, SA
    Senturk, Z
    TURKISH JOURNAL OF CHEMISTRY, 1996, 20 (04) : 323 - 328
  • [28] Voltammetric Determination of 5-Aminoquinoline at Carbon Film Electrode and Carbon and Gold Screen Printed Electrodes - A Comparative Study
    Jiranek, Ivan
    Barek, Jiri
    Matysik, Frank-Michael
    ELECTROANALYSIS, 2020, 32 (09) : 2002 - 2009
  • [29] Voltammetric Determination of α-Lipoic Acid using Carbon Fiber Microelectrode in Acetic Acid - Acetonitrile Solutions
    Skorupa, Agata
    Michalkiewicz, Slawomir
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (02): : 1581 - 1594
  • [30] Mechanism and kinetic considerations of TOC removal from the powdered activated carbon ozonation of diclofenac aqueous solutions
    Beltran, Fernando J.
    Pocostales, J. Pablo
    Alvarez, Pedro M.
    Jaramillo, Josefa
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 169 (1-3) : 532 - 538