Preconcentration of Cd(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples

被引:54
作者
Duran, Celal [1 ]
Ozdes, Duygu [1 ]
Sahin, Deniz [1 ]
Bulut, Volkan Numan [2 ]
Gundogdu, Ali [3 ]
Soylak, Mustafa [4 ]
机构
[1] Karadeniz Tech Univ, Dept Chem, Fac Sci, TR-61080 Trabzon, Turkey
[2] Karadeniz Tech Univ, Macka Vocat Sch, TR-61750 Macka Trabzon, Turkey
[3] Gumushane Univ, Fac Engn, Dept Food Engn, TR-29100 Gumushane, Turkey
[4] Erciyes Univ, Dept Chem, Fac Sci, TR-38039 Kayseri, Turkey
关键词
Carrier element free coprecipitation (CEFC); Trace analysis; Heavy metals; Preconcentration; Flame Atomic Absorption Spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; TRACE-METAL IONS; ENVIRONMENTAL-SAMPLES; MULTIELEMENT COPRECIPITATION; SEPARATION-PRECONCENTRATION; HEAVY-METALS; CEFC METHOD; SPECIATION; HYDROXIDE;
D O I
10.1016/j.microc.2011.02.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid, sensitive and environmentally friendly separation and preconcentration procedure, based on the carrier element free coprecipitation (CEFC) of Cu(II) and Cd(II) ions by using an organic coprecipitant, 2-{[4-(4-fluorophenyl)-5-sulphanyl-4H-1,2,4-triazol-3-yl]methyl}-4-{[(4-fluorophenyl) methylene]amino}-5-(4-methylphenyl)-2,4-dihydro-3H-1,2,4-triazol-3-one (MEFMAT) was developed. The analyte ions were determined by flame atomic absorption spectrometric (FAAS) determinations. The optimum conditions for the coprecipitation process were investigated on several commonly tested experimental parameters such as pH of the solution, amount of MEFMAT, sample volume, standing time, centrifugation rate and time. The influences of some anions. cations and transition metals on the recoveries of analyte ions were also investigated, and no considerable interference was observed. The preconcentration factor was found to be 50. The detection limits for Cu(II) and Cd(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 1.49 and 0.45 mu g L(-1), respectively. The relative standard deviations were found to be lower than 3.5% for both analyte ions. The method was validated by analyzing two certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) and spike tests. The procedure was successfully applied to sea water and stream water as liquid samples and tobacco, hazelnut and black tea as solid samples. (C) 0 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 38 条
[11]   Determination of copper, cadmium and lead in seawater and mineral water by flame atomic absorption spectrometry after coprecipitation with aluminum hydroxide [J].
Doner, G ;
Ege, A .
ANALYTICA CHIMICA ACTA, 2005, 547 (01) :14-17
[12]   Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS) [J].
Duran, Celal ;
Gundogdu, Ali ;
Bulut, Volkan Numan ;
Soylak, Mustafa ;
Elci, Latif ;
Senturk, Hasan Basri ;
Tufekci, Mehmet .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 146 (1-2) :347-355
[13]   Carrier element-free coprecipitation with 3-phenly-4-o-hydroxybenzylidenamino-4,5-dihydro-1,2,4-triazole-5-one for separation/preconcentration of Cr(III), Fe(III), Pb(II) and Zn(II) from aqueous solutions [J].
Duran, Celal ;
Bulut, Volkan N. ;
Gundogdu, Ali ;
Ozdes, Duygu ;
Yildirim, Nuri ;
Soylak, Mustafa ;
Senturk, H. Basri ;
Elci, Latif .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :294-299
[14]  
Duran C, 2009, J AOAC INT, V92, P257
[15]   Bi(III)4-methylpiperidinedithiocarbamate coprecipitation procedure for separation-pre-concentration of trace metal ions in water samples by flame atomic absorption spectrometric determination [J].
Efendioglu, Ayseguel ;
Yagan, Mehtap ;
Bati, Bekir .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 149 (01) :160-165
[16]   Determination of Zn(II) in natural waters by ICP-OES with on-line preconcentration using a simple solid phase extraction system [J].
Escudero, Luis A. ;
Martinez, Luis D. ;
Salonia, Jose A. ;
Gasquez, Jose A. .
MICROCHEMICAL JOURNAL, 2010, 95 (02) :164-168
[17]   Flow injection system for the on-line preconcentration of Pb by cloud point extraction coupled to USN-ICP OES [J].
Gil, Raul A. ;
Salonia, Jose A. ;
Gasquez, Jose A. ;
Olivieri, Alejandro C. ;
Olsina, Roberto ;
Martinez, Luis D. .
MICROCHEMICAL JOURNAL, 2010, 95 (02) :306-310
[18]   Elemental composition of seasoning products [J].
Gonzalvez, A. ;
Armenta, S. ;
Cervera, M. L. ;
de la Guardia, M. .
TALANTA, 2008, 74 (05) :1085-1095
[19]   Speciation analysis of mercury contaminants in water samples by RP-HPLC after solid phase extraction on modified C18 extraction disks with 1,3-bis(2-cyanobenzene)triazene [J].
Hashempur, Tahereh ;
Rofouei, Mohammad Kazem ;
Khorrami, Afshin Rajabi .
MICROCHEMICAL JOURNAL, 2008, 89 (02) :131-136
[20]   Flow injection on-line preconcentration with an ion-exchange resin coupled with microwave plasma torch-atomic emission spectrometry for the determination of trace rare earth elements [J].
Jia, Qiong ;
Kong, Xiangfei ;
Zhou, Weihong ;
Bi, Lihua .
MICROCHEMICAL JOURNAL, 2008, 89 (01) :82-87