Preconcentration of Cd(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples

被引:54
作者
Duran, Celal [1 ]
Ozdes, Duygu [1 ]
Sahin, Deniz [1 ]
Bulut, Volkan Numan [2 ]
Gundogdu, Ali [3 ]
Soylak, Mustafa [4 ]
机构
[1] Karadeniz Tech Univ, Dept Chem, Fac Sci, TR-61080 Trabzon, Turkey
[2] Karadeniz Tech Univ, Macka Vocat Sch, TR-61750 Macka Trabzon, Turkey
[3] Gumushane Univ, Fac Engn, Dept Food Engn, TR-29100 Gumushane, Turkey
[4] Erciyes Univ, Dept Chem, Fac Sci, TR-38039 Kayseri, Turkey
关键词
Carrier element free coprecipitation (CEFC); Trace analysis; Heavy metals; Preconcentration; Flame Atomic Absorption Spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; TRACE-METAL IONS; ENVIRONMENTAL-SAMPLES; MULTIELEMENT COPRECIPITATION; SEPARATION-PRECONCENTRATION; HEAVY-METALS; CEFC METHOD; SPECIATION; HYDROXIDE;
D O I
10.1016/j.microc.2011.02.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid, sensitive and environmentally friendly separation and preconcentration procedure, based on the carrier element free coprecipitation (CEFC) of Cu(II) and Cd(II) ions by using an organic coprecipitant, 2-{[4-(4-fluorophenyl)-5-sulphanyl-4H-1,2,4-triazol-3-yl]methyl}-4-{[(4-fluorophenyl) methylene]amino}-5-(4-methylphenyl)-2,4-dihydro-3H-1,2,4-triazol-3-one (MEFMAT) was developed. The analyte ions were determined by flame atomic absorption spectrometric (FAAS) determinations. The optimum conditions for the coprecipitation process were investigated on several commonly tested experimental parameters such as pH of the solution, amount of MEFMAT, sample volume, standing time, centrifugation rate and time. The influences of some anions. cations and transition metals on the recoveries of analyte ions were also investigated, and no considerable interference was observed. The preconcentration factor was found to be 50. The detection limits for Cu(II) and Cd(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 1.49 and 0.45 mu g L(-1), respectively. The relative standard deviations were found to be lower than 3.5% for both analyte ions. The method was validated by analyzing two certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) and spike tests. The procedure was successfully applied to sea water and stream water as liquid samples and tobacco, hazelnut and black tea as solid samples. (C) 0 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 38 条
[1]   Evaluation of toxic metals in biological samples (scalp hair, blood and urine) of steel mill workers by electrothermal atomic absorption spectrometry [J].
Afridi, Hassan I. ;
Kazi, Tasneem G. ;
Jamali, Mohammad K. ;
Kazi, Gul H. ;
Arain, Mohammad B. ;
Jalbani, Nusrat ;
Shar, Ghulam Q. ;
Sarfaraz, Raja A. .
TOXICOLOGY AND INDUSTRIAL HEALTH, 2006, 22 (09) :381-393
[2]  
[Anonymous], 1978, SPECTROCHEM ACTA, V33B, P241, DOI 10.1016/0584-8547(78)80044-5
[3]   A novel multi-element coprecipitation technique for separation and enrichment of metal ions in environmental samples [J].
Aydin, Funda Armagan ;
Soylak, Mustafa .
TALANTA, 2007, 73 (01) :134-141
[4]   A novel slurry sampling analysis of lead in different water samples by electrothermal atomic absorption spectrometry after coprecipitated with cobalt/pyrrolidine dithiocarbamate complex [J].
Baysal, A. ;
Akman, S. ;
Calisir, F. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 158 (2-3) :454-459
[5]   Speciation of hexavalent chromium in waters by liquid-liquid extraction and GFAAS determination [J].
Beni, Aron ;
Karosi, Roland ;
Posta, Jozsef .
MICROCHEMICAL JOURNAL, 2007, 85 (01) :103-108
[6]   A new approach to separation and pre-concentration of some trace metals with co-precipitation method using a triazole [J].
Bulut, Volkan Numan ;
Duran, Celal ;
Gundogdu, Ali ;
Soylak, Mustafa ;
Yildirim, Nuri ;
Elci, Latif .
TALANTA, 2008, 76 (02) :469-474
[7]   Preconcentration, separation and spectrophotometric determination of aluminium(III) in water samples and dialysis concentrates at trace levels with 8-hydroxyquinoline-cobalt(II) coprecipitation system [J].
Bulut, Volkan Numan ;
Arslan, Deniz ;
Ozdes, Duygu ;
Soylak, Mustafa ;
Tufekci, Mehmet .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 182 (1-3) :331-336
[8]   Carrier element-free coprecipitation (CEFC) method for the separation, preconcentration and speciation of chromium using an isatin derivative [J].
Bulut, Volkan Numan ;
Ozdes, Duygu ;
Bekircan, Olcay ;
Gundogdu, Ali ;
Duran, Celal ;
Soylak, Mustafa .
ANALYTICA CHIMICA ACTA, 2009, 632 (01) :35-41
[9]   Simultaneous coprecipitation of lead, cobalt, copper, cadmium, iron and nickel in food samples with zirconium(IV) hydroxide prior to their flame atomic absorption spectrometric determination [J].
Citak, Demirhan ;
Tuzen, Mustafa ;
Soylak, Mustafa .
FOOD AND CHEMICAL TOXICOLOGY, 2009, 47 (09) :2302-2307
[10]   Synthesis of some new 1,3,4-thiadiazol-2-ylmethyl-1,2,4-triazole derivatives and investigation of their antimicrobial activities [J].
Demirbas, Ahmet ;
Sahin, Deniz ;
Demirbas, Neslihan ;
Karaoglu, Senguel Alpay .
EUROPEAN JOURNAL OF MEDICINAL CHEMISTRY, 2009, 44 (07) :2896-2903