Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry

被引:28
|
作者
Robinson, Andrew P. [1 ]
Tipping, Jill [2 ]
Cullen, David M. [1 ]
Hamilton, David [2 ]
Brown, Richard [1 ]
Flynn, Alex [1 ]
Oldfield, Christopher [1 ]
Page, Emma [1 ,2 ]
Price, Emlyn [1 ]
Smith, Andrew [1 ]
Snee, Richard [1 ]
机构
[1] Univ Manchester, Schuster Lab, Sch Phys & Astron, Manchester M13 9PL, Lancs, England
[2] Christie NHS Fdn Trust, CMPE, Wilmslow Rd, Manchester M20 4BX, Lancs, England
来源
EJNMMI PHYSICS | 2016年 / 3卷 / 01期
基金
英国科学技术设施理事会;
关键词
Activity quantification; SPECT; Molecular radiotherapy; 3D printing; Absorbed dose; ABSORBED FRACTIONS; ELECTRONS; ACCURACY; SPHERES;
D O I
10.1186/s40658-016-0148-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Patient-specific absorbed dose calculations for molecular radiotherapy require accurate activity quantification. This is commonly derived from Single-Photon Emission Computed Tomography (SPECT) imaging using a calibration factor relating detected counts to known activity in a phantom insert. Methods: A series of phantom inserts, based on the mathematical models underlying many clinical dosimetry calculations, have been produced using 3D printing techniques. SPECT/CT data for the phantom inserts has been used to calculate new organ-specific calibration factors for Tc-99m and Lu-177. The measured calibration factors are compared to predicted values from calculations using a Gaussian kernel. Results: Measured SPECT calibration factors for 3D printed organs display a clear dependence on organ shape for Tc-99m and Lu-177. The observed variation in calibration factor is reproduced using Gaussian kernel-based calculation over two orders of magnitude change in insert volume for Tc-99m and Lu-177. These new organ-specific calibration factors show a 24, 11 and 8 % reduction in absorbed dose for the liver, spleen and kidneys, respectively. Conclusions: Non-spherical calibration factors from 3D printed phantom inserts can significantly improve the accuracy of whole organ activity quantification for molecular radiotherapy, providing a crucial step towards individualised activity quantification and patient-specific dosimetry. 3D printed inserts are found to provide a cost effective and efficient way for clinical centres to access more realistic phantom data.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [31] Wall-less vascular poly(vinyl) alcohol gel ultrasound imaging phantoms using 3D printed vessels
    Mackle, Eleanor C.
    Maneas, Efthymios
    Little, Callum
    Carr, Elizabeth
    Xia, Wenfeng
    Nikitichev, Daniil
    Rakhit, Roby D.
    Finlay, Malcolm C.
    Desjardins, Adrien E.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XII, 2019, 10870
  • [32] Verification of Acuros XB dose algorithm using 3D printed low-density phantoms for clinical photon beams
    Zavan, Rodolfo
    McGeachy, Philip
    Madamesila, Joseph
    Villarreal-Barajas, Jose-Eduardo
    Khan, Rao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 32 - 43
  • [33] Minimally invasive hallux valgus surgery using 3D printed patient specific instrumentation
    Ferreira, Gabriel Ferraz
    Nunes, Gustavo Araujo
    Banca, Vitor La
    Michaelis, Luiz Fernando
    Lewis, Thomas Lorchan
    Ray, Robbie
    Lam, Peter
    Pereira Filho, Miguel Viana
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (06) : 2553 - 2559
  • [34] Using 3D Printers to Create Complex Phantoms for Dose Verification, Quality Assurance, and Treatment Planning System Commissioning in Radiotherapy
    Kassaee, A.
    Ding, X.
    McDonough, J.
    Reiche, M.
    Witztum, A.
    Teo, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 515 - 515
  • [35] Applications and limitations of using patient-specific 3D printed molds in autologous breast reconstruction
    Hummelink S.
    Verhulst A.C.
    Maal T.J.J.
    Ulrich D.J.O.
    European Journal of Plastic Surgery, 2018, 41 (5) : 571 - 576
  • [36] Patient specific Polymethyl methacrylate customised cranioplasty using 3D printed silicone moulds: Technical note
    Scerrati, Alba
    Travaglini, Francesco
    Gelmi, Clarissa Ann Elisabeth
    Lombardo, Andrea
    De Bonis, Pasquale
    Cavallo, Michele Alessandro
    Zamboni, Paolo
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2022, 18 (02)
  • [37] Patient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer
    Choi, Yeonho
    Lee, Ik Jae
    Park, Kwangwoo
    Park, Kyung Ran
    Cho, Yeona
    Kim, Jun Won
    Lee, Ho
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [38] Comparison of low-contrast detectability between two CT reconstruction algorithms using voxel-based 3D printed textured phantoms
    Solomon, Justin
    Ba, Alexandre
    Bochud, Francois
    Samei, Ehsan
    MEDICAL PHYSICS, 2016, 43 (12) : 6497 - 6506
  • [39] Activity quantification combining conjugate-view planar scintigraphies and SPECT/CT data for patient-specific 3-D dosimetry in radionuclide therapy
    Yannick Berker
    Andreas Goedicke
    Gerrit J. Kemerink
    Til Aach
    Bernd Schweizer
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 2173 - 2185
  • [40] Activity quantification combining conjugate-view planar scintigraphies and SPECT/CT data for patient-specific 3-D dosimetry in radionuclide therapy
    Berker, Yannick
    Goedicke, Andreas
    Kemerink, Gerrit J.
    Aach, Til
    Schweizer, Bernd
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (12) : 2173 - 2185