Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry

被引:27
|
作者
Robinson, Andrew P. [1 ]
Tipping, Jill [2 ]
Cullen, David M. [1 ]
Hamilton, David [2 ]
Brown, Richard [1 ]
Flynn, Alex [1 ]
Oldfield, Christopher [1 ]
Page, Emma [1 ,2 ]
Price, Emlyn [1 ]
Smith, Andrew [1 ]
Snee, Richard [1 ]
机构
[1] Univ Manchester, Schuster Lab, Sch Phys & Astron, Manchester M13 9PL, Lancs, England
[2] Christie NHS Fdn Trust, CMPE, Wilmslow Rd, Manchester M20 4BX, Lancs, England
来源
EJNMMI PHYSICS | 2016年 / 3卷 / 01期
基金
英国科学技术设施理事会;
关键词
Activity quantification; SPECT; Molecular radiotherapy; 3D printing; Absorbed dose; ABSORBED FRACTIONS; ELECTRONS; ACCURACY; SPHERES;
D O I
10.1186/s40658-016-0148-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Patient-specific absorbed dose calculations for molecular radiotherapy require accurate activity quantification. This is commonly derived from Single-Photon Emission Computed Tomography (SPECT) imaging using a calibration factor relating detected counts to known activity in a phantom insert. Methods: A series of phantom inserts, based on the mathematical models underlying many clinical dosimetry calculations, have been produced using 3D printing techniques. SPECT/CT data for the phantom inserts has been used to calculate new organ-specific calibration factors for Tc-99m and Lu-177. The measured calibration factors are compared to predicted values from calculations using a Gaussian kernel. Results: Measured SPECT calibration factors for 3D printed organs display a clear dependence on organ shape for Tc-99m and Lu-177. The observed variation in calibration factor is reproduced using Gaussian kernel-based calculation over two orders of magnitude change in insert volume for Tc-99m and Lu-177. These new organ-specific calibration factors show a 24, 11 and 8 % reduction in absorbed dose for the liver, spleen and kidneys, respectively. Conclusions: Non-spherical calibration factors from 3D printed phantom inserts can significantly improve the accuracy of whole organ activity quantification for molecular radiotherapy, providing a crucial step towards individualised activity quantification and patient-specific dosimetry. 3D printed inserts are found to provide a cost effective and efficient way for clinical centres to access more realistic phantom data.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [21] Enabling Complex Fibre Geometries Using 3D Printed Axon-Mimetic Phantoms
    Kuehn, Tristan K.
    Mushtaha, Farah N.
    Khan, Ali R.
    Baron, Corey A.
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [22] Treatment Planning for Image-Guided Neuro-Vascular Interventions Using Patient-Specific 3D Printed Phantoms
    Russ, M.
    O'Hara, R.
    Nagesh, S. V. Setlur
    Mokin, M.
    Jimenez, C.
    Siddiqui, A.
    Bednarek, D.
    Rudin, S.
    Ionita, C.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [23] Comparison of fluid dynamics changes due to physical activity in 3D printed patient specific coronary phantoms with the Windkessel equivalent model of coronary flow
    Kelsey N. Sommer
    Mohammad Mahdi Shiraz Bhurwani
    Vijay Iyer
    Ciprian N. Ionita
    3D Printing in Medicine, 8
  • [24] Comparison of fluid dynamics changes due to physical activity in 3D printed patient specific coronary phantoms with the Windkessel equivalent model of coronary flow
    Sommer, Kelsey N.
    Bhurwani, Mohammad Mahdi Shiraz
    Iyer, Vijay
    Ionita, Ciprian N.
    3D PRINTING IN MEDICINE, 2022, 8 (01)
  • [25] Development and test of sets of 3D printed age-specific thyroid phantoms for 131I measurements
    Beaumont, Tiffany
    Ideias, Pedro Caldeira
    Rimlinger, Maeva
    Broggio, David
    Franck, Didier
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (12): : 4673 - 4693
  • [26] Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology
    Pacilio, Massimiliano
    Ferrari, Mahila
    Chiesa, Carlo
    Lorenzon, Leda
    Mira, Marta
    Botta, Francesca
    Becci, Domenico
    Alberto Torres, Leonel
    Coca Perez, Marco
    Vergara Gil, Alex
    Basile, Chiara
    Ljungberg, Michael
    Pani, Roberto
    Cremonesi, Marta
    MEDICAL PHYSICS, 2016, 43 (07) : 4053 - 4064
  • [27] Challenges in hemodynamics assessment in complex neurovascular geometries using computational fluid dynamics and benchtop flow simulation in 3D printed patient specific phantoms
    Paccione, Eric
    Ionita, Ciprian N.
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [28] 3D printed heterogeneous paediatric head and adult thorax phantoms for linear accelerator radiotherapy quality assurance: from fabrication to treatment delivery
    Bustillo, John Paul O.
    Posadas, Julia Rebecca D.
    Mata, Jacob L.
    Inocencio, Elrick T.
    Rosenfeld, Anatoly B.
    Lerch, Michael L. F.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (05):
  • [29] Patient-Specific 3D Printed Models of Renal Tumours Using Home-Made 3D Printer in Comparison with Commercial 3D Printer
    Liu, Dongting
    Sun, Zhonghua
    Chaichana, Thanapong
    Ducke, Werner
    Fan, Zhanming
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 303 - 308
  • [30] PixelPrint: Generating Patient-Specific Phantoms for Spectral CT using Dual Filament 3D Printing
    Pasyar, Pouyan
    Im, Jessica
    Mei, Kai
    Liu, Leening
    Sandvold, Olivia
    Geagan, Michael
    Noel, Peter B.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925