DIAGNOSTIC VALUE OF DIFFERENT 3-D SHEAR WAVE ELASTOGRAPHY SECTIONS IN THE DIAGNOSIS OF THYROID NODULES

被引:5
作者
Hu, Ziyue [1 ]
Lu, Man [1 ,3 ]
Wang, Xu [2 ]
Yang, Wei [1 ]
Fan, Yuting [1 ]
LI, Tingting [1 ]
Wang, Lu [1 ]
Wei, Ting [1 ]
机构
[1] Univ Elect Sci & Technol China, Sichuan Canc Hosp Inst, Sichuan Canc Ctr, Sch Med,Dept Ultrasound, Chengdu, Peoples R China
[2] Univ Elect Sci & Technol China, Sichuan Canc Hosp Inst, Sichuan Canc Ctr, Sch Med,Dept Head & Neck Surg, Chengdu, Peoples R China
[3] Univ Elect Sci & Technol China, Sichuan Canc Hosp Inst, Sichuan Canc Ctr, Sch Med,Dept Ultrasound, 55,Sect 4,South Renmin Rd, Chengdu, Peoples R China
关键词
Ultrasound; 3-D shear wave elastography; Thyroid nodules; BREAST MASSES; DATA SYSTEM; BENIGN; 2D; 3D;
D O I
10.1016/j.ultrasmedbio.2022.05.036
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of the study was to explore the value of 3-D shear wave elastography (SWE) in differentiating malignant from benign thyroid nodules. A total of 188 patients with 216 nodules who underwent conventional ultrasound, 2-D SWE and 3-D SWE were included in this study. All patients underwent surgical excision, and the pathological results were the gold standard. Receiver operating characteristic (ROC) curves of the American College of Radiology's Thyroid Imaging Reporting and Data System (ACR TI-RADS), 2-D SWE and 3-D SWE were plotted, and the areas under the curves (AUCs) were compared using a Z-test. There were 62 benign thyroid nodules and 154 malignant thyroid nodules in this study. Young's modulus (E-min, E-mean, E-max, E-sd) values of thy-roid malignant nodules in different sections of 2-D SWE and 3-D SWE were significantly higher than those of thy-roid benign nodules (p < 0.001). The AUC of E-max in 2-D SWE transverse sections was significantly lower than that in 3-D SWE transverse sections and 3-D SWE sagittal sections (0.768 vs. 0.831 and 0.844, p < 0.05). The AUC of 3-D S-Emax combined with ACR TI-RADS was 0.859; the specificity increased from 54.84% to 85.71%, and the diagnostic accuracy increased from 74.54% to 85.19%, compared with ACR TI-RADS. The difference was statistically significant (p < 0.05). Three-dimensional SWE combined with ACR TI-RADS for the diagnosis of thyroid nodules significantly improved the diagnostic ability of ACR TI-RADS, and was significantly better than 2-D SWE combined with ACR TI-RADS. (E-mail: graceof@163.com) (C) 2022 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1957 / 1965
页数:9
相关论文
共 50 条
  • [21] Accuracy of shear wave elastography in characterization of thyroid nodules in children and adolescents
    Mohammed Hazem
    Ossama M. Zakaria
    Mohamed Yasser Ibrahim Daoud
    Ibrahim Khalid Al Jabr
    Abdulwahab A. AlYahya
    Ahmed Gaber Hassanein
    Abdulrahim A. Alabdulsalam
    Mohammed Qasem AlAlwan
    Nahla Mohamed Ali Hasan
    Insights into Imaging, 12
  • [22] Shear wave elastography and contrast-enhanced ultrasonography in the diagnosis of thyroid malignant nodules
    Chen, Mei
    Zhang, Ke-Qin
    Xu, You-Feng
    Zhang, Sheng-Min
    Cao, Yong
    Sun, Wei-Qun
    MOLECULAR AND CLINICAL ONCOLOGY, 2016, 5 (06) : 724 - 730
  • [23] Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
    Kyriakidou, Georgia
    Friedrich-Rust, Mireen
    Bon, Dimitra
    Sircar, Ishani
    Schrecker, Christopher
    Bogdanou, Dimitra
    Herrmann, Eva
    Bojunga, Joerg
    PLOS ONE, 2018, 13 (09):
  • [24] Comparisons and Combined Application of Two-Dimensional and Three-Dimensional Real-time Shear Wave Elastography in Diagnosis of Thyroid Nodules
    Han, Rui-Jun
    Du, Jing
    Li, Feng-Hua
    Zong, Hao-Ru
    Wang, Jia-Dong
    Shen, Yu-Ling
    Zhou, Qin-Yi
    JOURNAL OF CANCER, 2019, 10 (09): : 1975 - 1984
  • [25] Diagnostic performance of shear wave elastography in the identification of malignant thyroid nodules: a meta-analysis
    Peiliang Lin
    Minqi Chen
    Baoxian Liu
    Siwen Wang
    Xiaoxi Li
    European Radiology, 2014, 24 : 2729 - 2738
  • [26] Investigation of the maximum Young's modulus of thyroid nodules using two-dimensional shear wave elastography in thyroid nodules.
    Hang, Jing
    Xue, Hai-yan
    Deng, Hong-yan
    Ye, Xin-hua
    Li, Cui-ying
    Ma, Wen-ting
    Li, Fan
    Du, Lian-fang
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (08): : 3537 - 3544
  • [27] Shear wave elastography combined with the thyroid imaging reporting and data system for malignancy risk stratification in thyroid nodules
    Liu, Zhao
    Jing, Hui
    Han, Xue
    Shao, Hua
    Sun, Yi-xin
    Wang, Qiu-cheng
    Cheng, Wen
    ONCOTARGET, 2017, 8 (26) : 43406 - 43416
  • [28] THE DIAGNOSTIC VALUE OF THE AMERICAN COLLEGE OF RADIOLOGY THYROID IMAGING REPORTING AND DATA SYSTEM CLASSIFICATION AND SHEAR-WAVE ELASTOGRAPHY FOR THE DIFFERENTIATION OF THYROID NODULES
    Makal, Gul Bora
    Aslan, Aydin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (05) : 1227 - 1234
  • [29] Three-Dimensional Shear Wave Elastography for Differentiating Benign From Malignant Thyroid Nodules
    Zhao, Chong-Ke
    Chen, Shi-Gao
    Alizad, Azra
    He, Ya-Ping
    Wang, Qiao
    Wang, Dan
    Yue, Wen-Wen
    Zhang, Kun
    Qu, Shen
    Wei, Qing
    Xu, Hui-Xiong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (07) : 1777 - 1788
  • [30] The value of quantitative shear wave elastography in differentiating the cervical lymph nodes in patients with thyroid nodules
    Jun You
    Juan Chen
    Feixiang Xiang
    Yue Song
    Simai Khamis
    Chengfa Lu
    Qing Lv
    Yanrong Zhang
    Mingxing Xie
    Journal of Medical Ultrasonics, 2018, 45 : 251 - 259