Monte Carlo calculated TG-43 dosimetry parameters for the SeedLink™ 125iodine brachytherapy system

被引:2
作者
Medich, DC
Munro, JJ
机构
[1] Univ Massachusetts, Radiat Lab, Lowell, MA 01854 USA
[2] Implant Sci Corp, Wakefield, MA 01880 USA
关键词
brachytherapy; iodine-125; prostate; radiation dosimetry; Monte Carlo;
D O I
10.1118/1.1601914
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The SeedLink(TM) brachytherapy system is comprised from an assembly of I-Plant(TM) 3500 interstitial brachytherapy seeds and bioresorbable spacers joined together by a 6-mm-long titanium sleeve centered over each seed. This device is designed to maintain specified spacing between seeds during treatment thereby decreasing implant preparation time and reducing radionuclide migration within the prostate and periprostatic region. Reliable clinical treatment and planning applications necessitate accurate dosimetric data for source evaluation, therefore the authors report the results of a Monte Carlo study designed to calculate the AAPM Task Group Report No. 43 dosimetric parameters for the SeedLink brachytherapy source and compare these values against previously published Monte Carlo study results of the I-Plant 3500 brachytherapy seed. For this investigation, a total of 1 X 10(9) source photon histories were processed for each set of in-water and in-air calculations using the MCNP4C2 Monte Carlo radiation transport code (RSICC). Statistically, the radial dose function, g(r), and the dose-rate constant, Lambda, were identical to the values calculated previously for the Model 3500 with the dose-rate constant evaluated to be Lambda=1.000+/-0.026 cGyh(-1) U-1. The titanium sleeve used in SeedLink to bind together Model 3500 seeds and spacers resulted in slightly greater dosimetric anisotropy as exhibited in the anisotropy function, F(r, theta), the anisotropy factor, phi(an) (r), and the anisotropy constant, (φ) over bar (an), which was calculated to be (φ) over bar (an)=0.91+/-0.01, or roughly 2% lower than the value calculated previously for the Model 3500. These results indicate that the radiological characteristics of the SeedLink dosimetry system are comparable to those obtained for previously characterized single seeds such as the Implant Sciences Model 3500 I-Plant seed. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2503 / 2508
页数:6
相关论文
共 50 条
[41]   Monte Carlo dose parameters of the BrachySeed model LS-1 125I brachytherapy source [J].
Wang, RQ ;
Sloboda, RS .
APPLIED RADIATION AND ISOTOPES, 2002, 56 (06) :805-813
[42]   Dosimetric parameters estimation using PENELOPE Monte-Carlo simulation code:: Model 6711 a 125I brachytherapy seed [J].
Rodríguez, EAV ;
Alcón, EPQ ;
Rodriguez, ML ;
Gutt, F ;
de Almeida, E .
APPLIED RADIATION AND ISOTOPES, 2005, 63 (01) :41-48
[43]   Complex cell geometry and sources distribution model for Monte Carlo single cell dosimetry with iodine 125 radioimmunotherapy [J].
Arnaud, F. X. ;
Paillas, S. ;
Pouget, J. P. ;
Incerti, S. ;
Bardies, M. ;
Bordage, M. C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 366 :227-233
[44]   MONTE CARLO SIMULATION-BASED DOSIMETRIC EVALUATION OF A NOVEL 125I BRACHYTHERAPY SOURCE Comparative Assessment of Dosimetry Parameters and Shadowing Effects [J].
Duo, Wan ;
Wang, Shuahua ;
Mostafa, Omar Medhat ;
Medhat, Moustafa Elsayed .
NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2024, 39 (04) :312-317
[45]   EVALUATION OF DOSIMETRIC PARAMETERS AND DISEASE RESPONSE AFTER 125IODINE TRANSPERINEAL BRACHYTHERAPY FOR LOW- AND INTERMEDIATE-RISK PROSTATE CANCER [J].
Morris, W. James ;
Keyes, Mira ;
Palma, David ;
McKenzie, Michael ;
Spadinger, Ingrid ;
Agranovich, Alex ;
Pickles, Tom ;
Liu, Mitchell ;
Kwan, Winkle ;
Wu, Jonn ;
Lapointe, Vince ;
Berthelet, Eric ;
Pai, Howard ;
Harrison, Robert ;
Kwa, William ;
Bucci, Joe ;
Racz, Violet ;
Woods, Ryan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05) :1432-1438
[46]   Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the 125I I-Seed AgX100 source model [J].
Mourtada, Firas ;
Mikell, Justin ;
Ibbott, Geoffrey .
BRACHYTHERAPY, 2012, 11 (03) :237-244
[47]   Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy [J].
Taherparvar, Payvand ;
Fardi, Zeinab .
NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 55 (02) :86-95
[48]   Ocular Brachytherapy Dosimetry for 103Pd and 125I in The Presence of Gold Nanoparticles: Monte Carlo Study [J].
Asadi, S. ;
Vaez-zadeh, M. ;
Vahidian, M. ;
Marghchouei, M. ;
Masoudi, S. Farhad .
RADIOTHERAPY AND ONCOLOGY, 2016, 118 :S105-S105
[49]   Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy [J].
Payvand Taherparvar ;
Zeinab Fardi .
Nuclear Medicine and Molecular Imaging, 2021, 55 :86-95
[50]   Ocular brachytherapy dosimetry for 103Pd and 125I in the presence of gold nanoparticles: a Monte Carlo study [J].
Asadi, Somayeh ;
Vaez-zadeh, Mehdi ;
Vahidian, Mohammad ;
Marghchouei, Mahdieh ;
Masoudi, S. Farhad .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :90-99