The Effect of Low Frame Rate Fluoroscopy on the X-ray Dose during Coronary Intervention

被引:4
|
作者
Sadamatsu, Kenji [1 ]
Nakano, Yasuhiro [1 ]
机构
[1] Saga Ken Med Ctr Koseikan, Dept Cardiol, Saga, Saga, Japan
关键词
percutaneous coronary intervention; radiation; angiography; fluoroscopy; X-rays; transradial; RADIATION-EXPOSURE; ANGIOGRAPHY; REDUCTION; PROTOCOL; OPERATOR; TRIAL;
D O I
10.2169/internalmedicine.55.6510
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective The aim of this study was to investigate whether the use of low frame rate fluoroscopy at 7.5 frames per second during coronary intervention could reduce radiation exposure in Japanese patients. Methods From December 10, 2014 to March 20, 2015, 84 consecutive patients with coronary artery disease who underwent coronary intervention in our institution were retrospectively collected and then divided into two groups: the LR group (fluoroscopy at 7.5 frames per second) and the OR group (fluoroscopy at 15 frames per second), according to the frame rate of fluoroscopy that was used in their treatment. Results There were no differences in the patient backgrounds or the procedural characteristics of the two groups. Although there were no differences in the contrast volume or fluoroscopy time, the total air kerma at the interventional reference point, which is used to monitor the patient's radiation dose, was significantly lower in the LR group than in the OR group (701.4 +/- 427.9 vs. 936.8 +/- 623.9 mGy, p=0.02). Conclusion Low frame rate fluoroscopy at 7.5 frames per second is safe and feasible for use during coronary interventions and an easy and useful strategy for reducing the radiation to which patients are exposed during coronary intervention.
引用
收藏
页码:1943 / 1946
页数:4
相关论文
共 50 条
  • [1] A propensity score matched valuation on feasibility of low frame rate fluoroscopy during primary percutaneous coronary intervention for patients with STEMI
    Fan, Lin
    Luo, Yukun
    Chen, Zhaoyang
    Cai, Wei
    Dong, Xianfeng
    Lin, Chaogui
    Chen, Lianglong
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (03): : 393 - 399
  • [2] Effect of Physician Training on the X-Ray Dose Delivered During Coronary Angioplasty
    Ramon Azpiri-Lopez, Jose
    Luis Assad-Morell, Jose
    Gerardo Gonzalez-Gonzalez, Jose
    Elizondo-Riojas, Guillermo
    Davila-Bortoni, Adrian
    Garcia-Martinez, Rodrigo
    Trevino-Frutos, Ramon
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (03): : 109 - 113
  • [3] Effect of Reduction of the Pulse Rates of Fluoroscopy and CINE-Acquisition on X-Ray Dose and Angiographic Image Quality During Invasive Cardiovascular Procedures
    Pyne, Christopher T.
    Gadey, Gautam
    Jeon, Cathy
    Piemonte, Thomas
    Waxman, Sergio
    Resnic, Frederic
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) : 441 - 446
  • [4] A propensity score matched valuation on feasibility of low frame rate fluoroscopy during primary percutaneous coronary intervention for patients with STEMI
    Lin Fan
    Yukun Luo
    Zhaoyang Chen
    Wei Cai
    Xianfeng Dong
    Chaogui Lin
    Lianglong Chen
    The International Journal of Cardiovascular Imaging, 2019, 35 : 393 - 399
  • [5] Radiation dose during catheter ablation in children using a low fluoroscopy frame rate
    Riche, Maya
    Monfraix, Sylvie
    Balduyck, Sebastien
    Voglimacci-Stephanopoli, Quentin
    Rollin, Anne
    Mondoly, Pierre
    Mandel, Franck
    Beneyto, Maxime
    Delasnerie, Hubert
    Derval, Nicolas
    Thambo, Jean Benoit
    Karsenty, Clement
    Dulac, Yves
    Acar, Philippe
    Mora, Stephanie
    Gautier, Romain
    Sacher, Frederic
    Maury, Philippe
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2022, 115 (03) : 151 - 159
  • [6] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY
    LABBE, MS
    CHIU, MY
    RZESZOTARSKI, MS
    BANIHASHEMI, AR
    WILSON, DL
    MEDICAL PHYSICS, 1994, 21 (03) : 471 - 481
  • [7] CdZnTe detector arrays for low-dose x-ray fluoroscopy
    Heanue, JA
    Pearson, DA
    Melen, RE
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 114 - 121
  • [8] Effectiveness of Low Rate Fluoroscopy at Reducing Operator and Patient Radiation Dose During Transradial Coronary Angiography and Interventions
    Abdelaal, Eltigani
    Plourde, Guillaume
    MacHaalany, Jimmy
    Arsenault, Jean
    Rimac, Goran
    Dery, Jean-Pierre
    Barbeau, Gerald
    Larose, Eric
    De larochelliere, Robert
    Nguyen, Can M.
    Allende, Ricardo
    Ribeiro, Henrique
    Costerousse, Olivier
    Mongrain, Rosaire
    Bertrand, Olivier F.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (05) : 567 - 574
  • [9] Development of an ultra-low-dose fluoroscopy system with real-time frame rate modulation using a fully digital x-ray tube
    Park, Sora
    Jeong, Jin-Woo
    Kim, Jae-Woo
    Kang, Jun-Tae
    Yun, Ki Nam
    Kim, Seong Jun
    Choi, Sunghoon
    Go, Eunsol
    Lee, Jeong-Woong
    Ahn, Yujung
    Yeon, Ji-Hwan
    Kim, Sunghee
    Song, Yoon-Ho
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [10] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150