A review on design characteristics and fabrication methods of metallic cardiovascular stents

被引:63
作者
Korei, Nima [1 ]
Solouk, Atefeh [1 ]
Nazarpak, Masoumeh Haghbin [1 ,2 ]
Nouri, Alireza [1 ]
机构
[1] Amirkabir Univ Technol, Biomed Engn Dept, Tehran Polytech, Tehran, Iran
[2] Amirkabir Univ Technol, New Technol Res Ctr NTRC, Tehran Polytech, Tehran, Iran
关键词
Metallic stents; Cardiovascular; Manufacturing; Bare metal stents; Drug-eluting stents; SHAPE-MEMORY-ALLOY; CORONARY-ARTERY STENTS; 316L STAINLESS-STEEL; IN-VITRO DEGRADATION; MAGNESIUM ALLOY; MECHANICAL-PROPERTIES; PLASTIC-DEFORMATION; CAROTID-ARTERY; MICRO-TUBES; ENDOVASCULAR TREATMENT;
D O I
10.1016/j.mtcomm.2022.103467
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The present review gives an overview of the composition and fabrication technologies of metallic cardiovascular stents and their effects on the stent characteristics and function. The fabrication process has a significant effect on the geometry and the design characteristics of the stent and imparts different microstructures, corrosion behavior, and mechanical properties to the fabricated stent. Therefore, the operational and functional efficiency of stents in the body is dependent on the manufacturing process. Several stents have been developed and used for the treatment of cardiovascular diseases since their introduction as atherosclerosis remedy, including bare-metal stents (BMS), drug-eluting stents (DES), and bio-resorbable stents (BRS). Accordingly, various methods have been evaluated to fabricate stents in accordance with desired performance. Although several reviews have been published on the function and clinical success of various stent materials, there is a lack of information about the impact of various fabrication methods of metallic stents on their final features and functionality. The current work investigates a variety of conventional and modern methods that are used for the fabrication of metallic cardiovascular stents.
引用
收藏
页数:23
相关论文
共 220 条
[1]  
AbuRahma AF, 2007, J ENDOVASC THER, V14, P698, DOI 10.1583/1545-1550(2007)14[698:AASVCB]2.0.CO
[2]  
2
[3]   Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device [J].
Ahlhelm, Frank ;
Roth, Christian ;
Kaufmann, Ralf ;
Schulte-Altedorneburg, Gernot ;
Romeike, Bernd F. M. ;
Reith, Wolfgang .
NEURORADIOLOGY, 2007, 49 (12) :1023-1028
[4]   Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial [J].
Ahlhelm, Frank ;
Kaufmann, Ralf ;
Ahlhelm, Dirk ;
Ong, Mai Fang ;
Roth, Christian ;
Reith, Wolfgang .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (05) :1019-1027
[5]   Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis [J].
Ahmed, Ahmed T. ;
Mohammed, Khaled ;
Chehab, Monzer ;
Brinjikji, Waleed ;
Murad, M. Hassan ;
Cloft, Harry ;
Bjarnason, Haraldur .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (05) :652-667
[6]   Determination of optimum parameters effect on kerf width of 316L stainless steel tube in Nd:YAG laser cutting [J].
Ahn, JM ;
Kim, HY ;
Kim, TH .
PRICM 5: THE FIFTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-5, 2005, 475-479 :277-280
[7]  
Aibibu D., 2016, ADV BRAIDING TECHNOL, P171
[8]   Spontaneous coronary artery dissection [J].
Al-Hussaini, Abtehale ;
Adlam, David .
HEART, 2017, 103 (13) :1043-1051
[9]   Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent [J].
Alexy, Ryan D. ;
Levi, Daniel S. .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013
[10]   Health Care Monitoring and Treatment for Coronary Artery Diseases: Challenges and Issues [J].
Alghrairi, Mokhalad ;
Sulaiman, Nasri ;
Mutashar, Saad .
SENSORS, 2020, 20 (15) :1-23