Monitoring of fouling within pipes using Electrical Impedance Spectroscopy

被引:1
作者
Anseth, Ronnie [1 ]
Skeie, Nils-Olav [1 ]
Waskaas, Magne [2 ]
机构
[1] Univ South Eastern Norway, Porsgrunn, Telemark, Norway
[2] Univ South Eastern Norway, Automat, Porsgrunn, Telemark, Norway
关键词
Pore resistance; in-situ monitoring; single frequency; TOMOGRAPHY;
D O I
10.1515/teme-2018-0012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The objective of the study described in this paper was to evaluate a monitoring system for fouling in pipes, based on impedance measurements using only one fixed frequency. The monitoring system observed the fouling growth (deposition layer and corrosion) inside a pipe which was subjected to a constant flow of liquid. The measurement frequency was specifically selected to optimize the sensitivity of the monitoring system towards the fouling growth. An electrical potential difference was applied to the pipe to generate an electrical field to accelerate the fouling growth in the experiment. Experimental results show a measurable change in the impedance magnitude (fouling growth) over the duration of the experiment (8 weeks). Results indicate that the measurement system, using one fixed frequency, is capable of in-situ monitoring of fouling growth in a pipe with a continuous flow of liquid.
引用
收藏
页码:627 / 634
页数:8
相关论文
共 50 条
[21]   Noninvasive treatment efficacy monitoring and dose control for high-intensity focused ultrasound therapy using relative electrical impedance variation [J].
Su, Huidan ;
Guo, Gepu ;
Ma, Qingyu ;
Tu, Juan ;
Zhang, Dong .
CHINESE PHYSICS B, 2017, 26 (05)
[22]   Reconstructing images in electrical impedance tomography using hybrid genetic algorithms [J].
Mendoza, Renier G. ;
Lope, Jose Ernie C. .
SCIENCE DILIMAN, 2012, 24 (02) :50-66
[23]   Functional Diagnostic using Electrical Impedance Tomography Reconstruction and the Internet of Things [J].
Pulavskyi, Anatolii A. ;
Krivenko, Sergey S. ;
Kryvenko, Liudmyla S. .
2017 6TH MEDITERRANEAN CONFERENCE ON EMBEDDED COMPUTING (MECO), 2017, :379-382
[24]   Bioelectrical Impedance Spectroscopy for Monitoring Mammalian Cells and Tissues under Different Frequency Domains: A Review [J].
Abasi, Sara ;
Aggas, John R. ;
Garayar-Leyva, Guillermo G. ;
Walther, Brandon K. ;
Guiseppi-Elie, Anthony .
ACS MEASUREMENT SCIENCE AU, 2022, 2 (06) :495-516
[25]   Detecting and Monitoring Oil Contamination Using Electrical Resistivity [J].
Khoury, Naji N. ;
Maalouf, Yara S. .
Geo-Chicago 2016: Sustainable Waste Management and Remediation, 2016, (273) :128-134
[26]   Minimally Invasive Real-Time Electrical Impedance Spectroscopy Diagnostic Tool for Lung Parenchyma Pathologies [J].
Riu, Pere J. ;
Company, Georgina ;
Bragos, Ramon ;
Rosell, Javier ;
Pajares, Virginia ;
Torrego, Alfons .
42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, :5077-5080
[27]   DETECTION OF CHANGES IN INTRATHORACIC FLUID IN MAN USING ELECTRICAL-IMPEDANCE TOMOGRAPHY [J].
CAMPBELL, JH ;
HARRIS, ND ;
ZHANG, F ;
MORICE, AH ;
BROWN, BH .
CLINICAL SCIENCE, 1994, 87 (01) :97-101
[28]   Noninvasive Glucose Monitoring With Low-Order Electrical Impedance Sensing Arrays: An Information Boosting Approach [J].
Liu, Yicun ;
Li, Junjie ;
Jia, Shiyue ;
Lu, Yi ;
Shi, Dawei ;
Shi, Ling .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
[29]   Bladder Boundary Estimation by Gravitational Search Algorithm Using Electrical Impedance Tomography [J].
Sharma, Sunam Kumar ;
Konki, Sravan Kumar ;
Khambampati, Anil Kumar ;
Kim, Kyung Youn .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (12) :9657-9667
[30]   Three-Dimensional (3D) cell culture monitoring: Opportunities and challenges for impedance spectroscopy [J].
De Leon, Sorel E. ;
Pupovac, Aleta ;
McArthur, Sally L. .
BIOTECHNOLOGY AND BIOENGINEERING, 2020, 117 (04) :1230-1240