Modelling and Analysis of PV-Based Shunt Active Filter with BESS and Conservative Power Theory for Enhancing Power Quality

被引:3
作者
Ramalingam, Gomathi [1 ]
Choudhary, Ajay Kumar [1 ]
Mikkili, Suresh [2 ]
机构
[1] Natl Inst Technol Goa, Ponda, Goa, India
[2] Natl Inst Technol Goa, Elect & Elect Engn, Farmagudi North Goa, India
来源
INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS | 2019年 / 20卷 / 06期
关键词
conservative power theory; power quality enhancement; PV array; perturb and observe (P&O); battery energy storage system (BESS); REACTIVE POWER; VOLTAGE; CURRENTS;
D O I
10.1515/ijeeps-2019-0012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power Quality has always been a major concern ever since the increase in the usage of many power electronic loads such as Personal Computers (PCs), TVs, variable frequency drives in nearly every household. These loads are a major source of harmonics into the distribution system. Unbalanced Three-phase loads or different single-phase loads result in unbalance in the three-phase voltages and currents in the grid. Equipment damage, Loss of data, nuisance tripping, overheating of wires, relay tripping are few of the major issues caused due to power quality. Also, there is an increase in the awareness about the various power quality issues as well as its ill-effects amongst the consumers. Hence, it is essential to improve the quality of the power supplied. Active and Passive filters play a huge role in the mitigation of power quality issues. In recent years, usage of active filters has increased because tuning is possible for various harmonic elimination and active filters when combined with a storage system can provide active as well as reactive power compensation. The fast depletion of non-renewable sources of energy and its effect on the environment has shifted the focus on the usage of non-renewable energy sources such as solar energy, wind energy, etc for the production of electricity. In this research work, solar energy is combined with shunt active filter for the mitigation of various power quality issues occurring in a grid-connected non-linear and unbalanced three-phase load. The active power filter will provide reactive power compensation to the non-linear load and active power delivery for unbalanced loads such the grid current and voltage will remain balanced and the stress on the grid is reduced while meeting the load demand. A battery system is also integrated to store the excess energy that may be generated by the Photo-Voltaic(PV) array and acts as a source of energy when PV array output is low or nil. Conservative Power Theory is used for controlling the power injection into the system by the Voltage Source Converter(VSC). The proposed system is verified using MATLAB/SIMULINK.
引用
收藏
页数:21
相关论文
共 50 条
[31]   Experimental Investigations on Photovoltaic Interface Neutral Point Clamped Multilevel Inverter-Based Shunt Active Power Filter to Enhance Grid Power Quality [J].
Boopathi, Rajendran ;
Indragandhi, Vairavasundaram .
IEEE ACCESS, 2024, 12 :74482-74498
[32]   Type-2 Fuzzy Logic Controlled Three-level Shunt Active Power Filter for Power Quality Improvement [J].
Suresh, Dhanavath ;
Singh, Saijan Pal .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (08) :873-882
[33]   Active Power Filter for Power Quality in Grid Connected PV-System using an Improved Fuzzy Logic Control MPPT [J].
Tali, Mouna ;
Esadki, Ahmed ;
Nasser, Tamou ;
Boukezata, Boualem .
2018 6TH INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2018, :900-906
[34]   A New DeadBeat-Based Direct Power Control of Shunt Active Power Filter With Digital Implementation Delay Compensation [J].
Pichan, Mohammad ;
Seyyedhosseini, Mohsen ;
Hafezi, Hossein .
IEEE ACCESS, 2022, 10 :72866-72878
[35]   Fuzzy Membership Functions Based Active Filter for Power Quality Improvement [J].
Pedapenki, Kishore Kumar ;
Gupta, S. P. ;
Pathak, Mukesh Kumar .
2015 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES (ICCICCT), 2015, :231-235
[36]   A Robust Extended Complex Kalman Filter and Sliding-mode Control Based Shunt Active Power Filter [J].
Panigrahi, Rakhee ;
Panda, Prafulla Chandra ;
Subudhi, Bidyadhar .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2014, 42 (05) :520-532
[37]   Response Analysis of Shunt Active Power Filter Under Various Line and Load Side Conditions [J].
Shah, M. ;
Nagotha, D. .
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING 2016 (ICCASP 2016), 2017, 137 :395-403
[38]   Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current [J].
Bielecka, Agata ;
Wojciechowski, Daniel .
ENERGIES, 2021, 14 (08)
[39]   Grid Harmonic Current Correction Based on Parallel Three-Phase Shunt Active Power Filter [J].
De souza, Laysa L. ;
Rocha, Nady ;
Fernandes, Darlan A. ;
De Sousa, Reuben P. R. ;
Jacobina, Cursino B. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (02) :1422-1434
[40]   Performance Investigation of High Level Modular Multilevel Inverter based Shunt Hybrid Active Power Filter [J].
Demirdelen, Tugce ;
Kayaalp, Rahmi Ilker ;
Tumay, Mehmet .
2016 INTERNATIONAL SYMPOSIUM ON FUNDAMENTALS OF ELECTRICAL ENGINEERING (ISFEE), 2016,