Modelling and Analysis of PV-Based Shunt Active Filter with BESS and Conservative Power Theory for Enhancing Power Quality

被引:3
作者
Ramalingam, Gomathi [1 ]
Choudhary, Ajay Kumar [1 ]
Mikkili, Suresh [2 ]
机构
[1] Natl Inst Technol Goa, Ponda, Goa, India
[2] Natl Inst Technol Goa, Elect & Elect Engn, Farmagudi North Goa, India
关键词
conservative power theory; power quality enhancement; PV array; perturb and observe (P&O); battery energy storage system (BESS); REACTIVE POWER; VOLTAGE; CURRENTS;
D O I
10.1515/ijeeps-2019-0012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power Quality has always been a major concern ever since the increase in the usage of many power electronic loads such as Personal Computers (PCs), TVs, variable frequency drives in nearly every household. These loads are a major source of harmonics into the distribution system. Unbalanced Three-phase loads or different single-phase loads result in unbalance in the three-phase voltages and currents in the grid. Equipment damage, Loss of data, nuisance tripping, overheating of wires, relay tripping are few of the major issues caused due to power quality. Also, there is an increase in the awareness about the various power quality issues as well as its ill-effects amongst the consumers. Hence, it is essential to improve the quality of the power supplied. Active and Passive filters play a huge role in the mitigation of power quality issues. In recent years, usage of active filters has increased because tuning is possible for various harmonic elimination and active filters when combined with a storage system can provide active as well as reactive power compensation. The fast depletion of non-renewable sources of energy and its effect on the environment has shifted the focus on the usage of non-renewable energy sources such as solar energy, wind energy, etc for the production of electricity. In this research work, solar energy is combined with shunt active filter for the mitigation of various power quality issues occurring in a grid-connected non-linear and unbalanced three-phase load. The active power filter will provide reactive power compensation to the non-linear load and active power delivery for unbalanced loads such the grid current and voltage will remain balanced and the stress on the grid is reduced while meeting the load demand. A battery system is also integrated to store the excess energy that may be generated by the Photo-Voltaic(PV) array and acts as a source of energy when PV array output is low or nil. Conservative Power Theory is used for controlling the power injection into the system by the Voltage Source Converter(VSC). The proposed system is verified using MATLAB/SIMULINK.
引用
收藏
页数:21
相关论文
共 50 条
[21]   Switching Losses Analysis of an Asymmetric Multilevel Shunt Active Power Filter [J].
Munoz, Javier ;
Baier, Carlos ;
Espinoza, Jose ;
Rivera, Marco ;
Guzman, Johan ;
Rohten, Jaime .
39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, :8534-8539
[22]   PSO-GWO Optimized Fractional Order PID Based Hybrid Shunt Active Power Filter for Power Quality Improvements [J].
Mishra, Alok Kumar ;
Das, Soumya Ranjan ;
Ray, Prakash K. ;
Mallick, Ranjan Kumar ;
Mohanty, Asit ;
Mishra, Dillip K. .
IEEE ACCESS, 2020, 8 :74497-74512
[23]   Design, Simulation and Analysis of Shunt Active Power Filter using Instantaneous Reactive Power Topology [J].
Srivastava, Gaurava Deep ;
Kulkarni, Rajendrakumar D. .
2017 INTERNATIONAL CONFERENCE ON NASCENT TECHNOLOGIES IN ENGINEERING (ICNTE-2017), 2017,
[24]   Solar Photovoltaic System Interfaced Shunt Active Power Filter for Enhancement of Power Quality in Three-Phase Distribution System [J].
Senguttuvan, S. ;
Vijayakumar, M. .
JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2018, 27 (11)
[25]   Current Controllers of Active Power Filter for Power Quality Improvement: A Technical Analysis [J].
Dey, Papan ;
Mekhilef, Saad .
AUTOMATIKA, 2015, 56 (01) :42-54
[26]   SOGI Algorithm-Based Shunt Active Power Filter for Grid Integration of Photovoltaic Systems [J].
Manimekalai, P. ;
Harikumar, R. ;
Raghavan, S. .
JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2016, 25 (05)
[27]   Shunt active-power-filter topology based on parallel interleaved inverters [J].
Asiminoaei, Lucian ;
Aeloiza, Eddy ;
Enjeti, Prasad N. ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (03) :1175-1189
[28]   A Lyapunov Stability Theory-Based Control Strategy for Three-Level Shunt Active Power Filter [J].
Cao, Yijia ;
Xu, Yong ;
Li, Yong ;
Yu, Jiaqi ;
Yu, Jingrong .
ENERGIES, 2017, 10 (01)
[29]   Simulation modelling and analysis of modular cascaded multilevel converter based shunt hybrid active power filter for large scale photovoltaic system interconnection [J].
Demirdelen, T. ;
Kayaalp, R. I. ;
Tumay, M. .
SIMULATION MODELLING PRACTICE AND THEORY, 2017, 71 :27-44
[30]   Analysis and implementation of shunt active power filter with three-level PWM scheme [J].
Lin, BR ;
Huang, CH ;
Yang, TY ;
Lee, YC .
PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, :1580-1585