Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison

被引:76
作者
Bassinet, C. [1 ]
Woda, C. [2 ]
Bortolin, E. [3 ]
Della Monaca, S. [3 ]
Fattibene, P. [3 ]
Quattrini, M. C. [3 ]
Bulanek, B. [4 ]
Ekendahl, D. [4 ]
Burbidge, C. I. [5 ]
Cauwels, V. [6 ]
Kouroukla, E. [7 ]
Geber-Bergstrand, T. [8 ]
Mrozik, A. [9 ]
Marczewska, B. [9 ]
Bilski, P. [9 ]
Sholom, S. [10 ]
McKeever, S. W. S. [10 ]
Smith, R. W. [11 ]
Veronese, I. [12 ]
Galli, A. [13 ,14 ,15 ]
Panzeri, L. [14 ,15 ]
Martini, M. [14 ,15 ]
机构
[1] Inst Radioprotect & Surete Nucl, F-92262 Fontenay Aux Roses, France
[2] HMGU Helmholtz Zentrum Munchen, D-85764 Neuherberg, Germany
[3] Ist Super Sanita, I-00161 Rome, Italy
[4] Natl Radiat Protect Inst, Prague 14000 4, Czech Republic
[5] Univ Lisbon, Inst Super Tecn, P-2695066 Bobadela Lrs, Portugal
[6] CEN SCK, Belgian Nucl Res Ctr, B-2400 Mol, Belgium
[7] Univ Durham, Dept Archaeol, Luminescence Dating Serv, Durham DH1 3LE, England
[8] Lund Univ, Dept Clin Sci, Malmo, Sweden
[9] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
[10] Oklahoma State Univ, Dept Phys, Radiat Dosimetry Lab, Stillwater, OK 74078 USA
[11] Publ Hlth England, CRCE, Didcot, Oxon, England
[12] Univ Milan, Dipartimento Fis, I-20133 Milan, Italy
[13] CNR IFN, I-20133 Milan, Italy
[14] Ist Nazl Fis Nucl, I-20125 Milan, Italy
[15] Univ Milano Bicocca, Dept Mat Sci, I-20125 Milan, Italy
关键词
Retrospective dosimetry; Radiological accident; Emergency dosimeter; OSL; Resistor; Mobile phones; ACCIDENT DOSIMETRY;
D O I
10.1016/j.radmeas.2014.03.016
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:475 / 479
页数:5
相关论文
共 9 条
[1]   BiodosEPR-2006 Meeting: Acute dosimetry consensus committee recommendations on biodosimetry applications in events involving uses of radiation by terrorists and radiation accidents [J].
Alexander, George A. ;
Swartz, Harold M. ;
Amundson, Sally A. ;
Blakely, William F. ;
Buddemeier, Brooke ;
Gallez, Bernard ;
Dainiak, Nicholas ;
Goans, Ronald E. ;
Hayes, Robert B. ;
Lowry, Patrick C. ;
Noska, Michael A. ;
Okunieff, Paul ;
Salner, Andrew L. ;
Schauer, David A. ;
Trompier, Francois ;
Turteltaub, Kenneth W. ;
Voisin, Phillipe ;
Wiley, Albert L., Jr. ;
Wilkins, Ruth .
RADIATION MEASUREMENTS, 2007, 42 (6-7) :972-996
[2]   RADIATION ACCIDENT DOSIMETRY ON ELECTRONIC COMPONENTS BY OSL [J].
Bassinet, C. ;
Trompier, F. ;
Clairand, I. .
HEALTH PHYSICS, 2010, 98 (02) :440-445
[3]   Retrospective dosimetry with alumina substrate from electronic components [J].
Ekendahl, Daniela ;
Judas, Libor .
RADIATION PROTECTION DOSIMETRY, 2012, 150 (02) :134-141
[4]  
Fattibene F., 2014, RAD ENV BIO IN PRESS
[5]   Thermoluminescence of chip inductors from mobile phones for retrospective and accident dosimetry [J].
Fiedler, I. ;
Woda, C. .
RADIATION MEASUREMENTS, 2011, 46 (12) :1862-1865
[6]   Optically stimulated luminescence of electronic components for forensic, retrospective, and accident dosimetry [J].
Inrig, E. L. ;
Godfrey-Smith, D. I. ;
Khanna, S. .
RADIATION MEASUREMENTS, 2008, 43 (2-6) :726-730
[7]   The potential of luminescence signals from electronic components for accident dosimetry [J].
Pascu, A. ;
Vasiliniuc, S. ;
Zeciu-Dolha, M. ;
Timar-Gabor, A. .
RADIATION MEASUREMENTS, 2013, 56 :384-388
[8]  
Woda, 2014, DEV OPTIMIZED OSL PR
[9]   On the OSL curve shape and preheat treatment of electronic components from portable electronic devices [J].
Woda, Clemens ;
Greilich, Steffen ;
Beerten, Koen .
RADIATION MEASUREMENTS, 2010, 45 (3-6) :746-748