4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry

被引:53
作者
Paganetti, H [1 ]
Jiang, H [1 ]
Trofimov, A [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Boston, MA USA
关键词
D O I
10.1088/0031-9155/50/5/020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
When dosimetric effects in time-dependent geometries are studied, usually either the results of individual three-dimensional (3D) calculations are combined or probability-based approaches are applied. These methods may become cumbersome and time-consuming if high time resolution is required or if the geometry is complex. Furthermore, it is difficult to study double-dynamic systems, e.g., to investigate the influence of time-dependent beam delivery (i.e., magnetically moving beam spots in proton beam scanning) on the dose deposition in a moving target. We recently introduced the technique of 4D Monte Carlo dose calculation to model continuously changing geometries. In intensity modulated proton therapy, dose is delivered by individual pristine Bragg curves. Dose spots are positioned in the patient by varying magnetic field and beam energy. If the movement of these dose spots occurs during significant respiratory motion, interplay effects can take place. Because of the inhomogeneity of individual subfields, the consequences of motion can be more severe than in conventional proton therapy. We demonstrate how the technique of 4D Monte Carlo can be used to study interplay effects in proton beam scanning. Time-dependent beam delivery to a changing patient geometry is simulated in a single 4D dose calculation. Interplay effects between respiratory motion and beam scanning speed are demonstrated.
引用
收藏
页码:983 / 990
页数:8
相关论文
共 29 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
Booth J. T., 1999, Australasian Physical and Engineering Sciences in Medicine, V22, P29
[3]   Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Nijssen-Visser, MRJ ;
Graveland, WJ ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :348-354
[4]   BEAM SCANNING FOR HEAVY CHARGED-PARTICLE RADIOTHERAPY [J].
GOITEIN, M ;
CHEN, GTY .
MEDICAL PHYSICS, 1983, 10 (06) :831-840
[5]   Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation [J].
Hanley, J ;
Debois, MM ;
Mah, D ;
Mageras, GS ;
Raben, A ;
Rosenzweig, K ;
Mychalczak, B ;
Schwartz, LH ;
Gloeggler, PJ ;
Lutz, W ;
Ling, CC ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :603-611
[6]   Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data [J].
Jiang, H ;
Paganetti, H .
MEDICAL PHYSICS, 2004, 31 (10) :2811-2818
[7]   SPOT SCANNING SYSTEM FOR PROTON RADIOTHERAPY [J].
KANAI, T ;
KAWACHI, K ;
KUMAMOTO, Y ;
OGAWA, H ;
YAMADA, T ;
MATSUZAWA, H .
MEDICAL PHYSICS, 1980, 7 (04) :365-369
[8]   Monte Carlo dose calculations for dynamic IMRT treatments [J].
Keall, PJ ;
Siebers, JV ;
Arnfield, M ;
Kim, JO ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :929-941
[9]   RANGE MODULATORS FOR PROTONS AND HEAVY-IONS [J].
KOEHLER, AM ;
SCHNEIDER, RJ ;
SISTERSON, JM .
NUCLEAR INSTRUMENTS & METHODS, 1975, 131 (03) :437-440
[10]   Has 3-D conformal radiotherapy (3D CRT) improved the local tumour control for stage I non-small cell lung cancer? [J].
Lagerwaard, FJ ;
Senan, S ;
van Meerbeeck, JP ;
Graveland, WJ .
RADIOTHERAPY AND ONCOLOGY, 2002, 63 (02) :151-157