Constrained Image-Based B0 Shimming Accounting for "Local Minimum Traps" in the Optimization and Field Inhomogeneities Outside the Region of Interest

被引:41
作者
Fillmer, Ariane [1 ,2 ]
Kirchner, Thomas [1 ,2 ]
Cameron, Donnie [3 ]
Henning, Anke [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, CH-8092 Zurich, Switzerland
[3] Univ Aberdeen, Aberdeen, Scotland
[4] Max Planck Inst Biol Cybernet, D-72076 Tubingen, Germany
关键词
B-0; shimming; image-based B-0 shimming; projection-based B-0 shimming; shim term interactions; region of less interest; constrained fitting; magnetic resonance spectroscopic imaging; HUMAN BRAIN; WINDING PATTERNS; MAGNETIC-FIELD; COILS; ORDER;
D O I
10.1002/mrm.25248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo improve B-0 shimming for applications in high- and ultrahigh-field magnetic resonance imaging and magnetic resonance spectroscopy. MethodsAn existing image-based constrained B-0 shimming algorithm was enhanced using two techniques: (1) A region of less interest was introduced to control B-0 field inhomogeneities in the vicinity of the region of interest; (2) multiple sets of starting values were used for the fitting routine, to avoid getting trapped in a local minimum of the optimization function. The influence of constraints during the fitting procedure, due to hardware limitations, on the B-0 shim result was investigated. The performance of this algorithm was compared to other B-0 shim algorithms for typical shim problems in head and body applications at 3T and 7T. ResultsUtilization of a weighted region of less interest lead to a significant gain in B-0 homogeneity adjacent to the region of interest. The loss of B-0 quality due to the enlarged total shim volume within the region of interest remained minimal, allowing for improved artifact reduction in magnetic resonance spectroscopic imaging. Multiple sets of starting values and consideration of shim field constraints led to an additional gain in B-0 shim quality. ConclusionThe proposed algorithm allows for more flexible control of B-0 inhomogeneities and, hence, enables gains in image and spectral quality for MR applications. Magn Reson Med 73:1370-1380, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1370 / 1380
页数:11
相关论文
共 35 条
[1]  
[Anonymous], P ISMRM
[2]  
[Anonymous], P 17 ANN M ISMRM HON
[3]   High-field MRS of the human brain at short TE and TR [J].
Boer, Vincent O. ;
Siero, Jeroen C. W. ;
Hoogduin, Hans ;
van Gorp, Jetse S. ;
Luijten, Peter R. ;
Klomp, Dennis W. J. .
NMR IN BIOMEDICINE, 2011, 24 (09) :1081-1088
[4]   High-resolution mapping of human brain metabolites by free induction decay 1H MRSI at 7?T [J].
Bogner, W. ;
Gruber, S. ;
Trattnig, S. ;
Chmelik, M. .
NMR IN BIOMEDICINE, 2012, 25 (06) :873-882
[5]   Winding patterns for actively shielded shim coils with asymmetric target-fields [J].
Brideson, MA ;
Forbes, LK ;
Crozier, S .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (04) :484-493
[6]   Determining complicated winding patterns for shim coils using stream functions and the target-field method [J].
Brideson, MA ;
Forbes, LK ;
Crozier, S .
CONCEPTS IN MAGNETIC RESONANCE, 2002, 14 (01) :9-18
[7]   AUTOMATIC, LOCALIZED INVIVO ADJUSTMENT OF ALL 1ST-ORDER AND 2ND-ORDER SHIM COILS [J].
GRUETTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :804-811
[8]   FAST, NONITERATIVE SHIMMING OF SPATIALLY LOCALIZED SIGNALS - INVIVO ANALYSIS OF THE MAGNETIC-FIELD ALONG AXES [J].
GRUETTER, R ;
BOESCH, C .
JOURNAL OF MAGNETIC RESONANCE, 1992, 96 (02) :323-334
[9]  
Gruetter R, 2000, MAGNET RESON MED, V43, P319, DOI 10.1002/(SICI)1522-2594(200002)43:2<319::AID-MRM22>3.0.CO
[10]  
2-1