Preparation of electrochemically treated nanoporous pencil-graphite electrodes for the simultaneous determination of Pb and Cd in water samples

被引:18
作者
Donmez, Koray B. [1 ,2 ]
Cetinkaya, Ebru [1 ]
Deveci, Seda [1 ]
Karadag, Sevinc [1 ]
Sahin, Yucel [2 ]
Dogu, Mustafa [1 ]
机构
[1] Mir Arastirma & Gelistirme AS, Mat & Chem Res Dept, TR-34220 Istanbul, Turkey
[2] Yildiz Tech Univ, Dept Chem, Fac Sci & Art, TR-34220 Istanbul, Turkey
关键词
Electrochemical pretreatment; Nanoporous pencil graphite electrode; Determination of Pb and Cd; Voltammetry; Determination of heavy metal; ANODIC-STRIPPING VOLTAMMETRY; GLASSY-CARBON ELECTRODE; TRACE HEAVY-METALS; TAP WATER; PB(II); LEAD; CD(II); SOIL; ZN; CU;
D O I
10.1007/s00216-017-0426-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and rapid analytical method of determining Pb2+ and Cd2+ in water samples using an electrochemically pretreated pencil-graphite electrode (EP-PGE) is proposed for the first time in the literature. An electrochemically pretreated pencil-graphite electrode was prepared by performing potential cycling between -0.3 V and 2.0 V in 0.1 mol L-1 H3PO4 solution to improve its ability to electrochemically sense Pb2+ and Cd2+ ions. Square-wave anodic stripping voltammetry (SWASV) was used as the electroanalytical method. The electroanalytical parameters that influence the stripping determination of Pb2+ and Cd2+ were optimized based on experimental results. The magnitude of the peak oxidation current was adjusted in order to optimize the value of each parameter. Applying the resulting disposable electrode under the optimized conditions led to good selectivity and sensitivity in the determination of Pb2+ and Cd2+ ions. Interference from coexisting ions was also investigated. The resulting sensor was successfully tested by applying it to a standard reference water sample. Under the optimized conditions, the limits of detection were 0.46 mu g L-1 for Pb2+ and 1.11 mu g L-1 for Cd2+ using the electrode. Relative standard deviations (%RSD) were 2.76 for Pb2+ and 2.85 for Cd2+. The linear working ranges of the electrode for Pb2+ and Cd2+ ion detection were 5-45 mu g L-1 and 10-40 mu g L-1, respectively.
引用
收藏
页码:4827 / 4837
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 1987, ANALYST, V112, P199
[2]   A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry [J].
Demetriades, D ;
Economou, A ;
Voulgaropoulos, A .
ANALYTICA CHIMICA ACTA, 2004, 519 (02) :167-172
[3]   Voltammetry determination of trace manganese with pretreatment glassy carbon electrode by linear sweep voltammetry [J].
Di, JW ;
Zhang, F .
TALANTA, 2003, 60 (01) :31-36
[4]  
Donmez KB, 2017, IONICS, DOI [10.1007/s115810172040-y, DOI 10.1007/S115810172040-Y]
[5]   Direct and simultaneous voltammetric analysis of heavy metals in tap water samples at Assiut city: an approach to improve the analysis time for nickel and cobalt determination at mercury film electrode [J].
Farghaly, OA .
MICROCHEMICAL JOURNAL, 2003, 75 (02) :119-131
[6]   Square-wave stripping voltammetry for direct determination of eight heavy metals in soil and indoor-airborne particulate matter [J].
Farghaly, OA ;
Ghandour, MA .
ENVIRONMENTAL RESEARCH, 2005, 97 (03) :229-235
[7]  
Fox M.R.S., 1988, Handbook on Toxicity of Inotganic Compounds, P345
[8]   Voltammetric and electrochemical impedimetric behavior of silica-based gel electrolyte for valve-regulated lead-acid battery [J].
Gencten, Metin ;
Donmez, Koray B. ;
Sahin, Yucel ;
Pekmez, Kadir ;
Suvaci, Ender .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (09) :2469-2479
[9]   Electrochemically pretreated glassy carbon electrode for electrochemical detection of fenitrothion in tap water and human urine [J].
Geremedhin, Welesamel ;
Amare, Maereg ;
Admassie, Shimelis .
ELECTROCHIMICA ACTA, 2013, 87 :749-755
[10]   Determination of trace metals by anodic stripping voltammetry using a bismuth-modified carbon nanotube electrode [J].
Hwang, Gil Ho ;
Han, Won Kyu ;
Park, Joon Shik ;
Kang, Sung Goon .
TALANTA, 2008, 76 (02) :301-308